• 제목/요약/키워드: IR-heater

검색결과 41건 처리시간 0.024초

FT-IR을 이용한 철도차량용 내장재료별 독성성분의 발생량 비교 (Toxic gases's comparison of the railway car's interior materials using a FT-IR)

  • 이은경;정우성;이덕희;박덕신;이철규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1254-1260
    • /
    • 2005
  • The advanced country established the test standard (e.g., BS, EN) to measure the toxic gases quantitatively and, have applied to enhance the fire safety of railway car. We must also follow the procedures to use interior material for railway car as stated the Safety regulation for the urban railway car. Currently, various interior materials are used to obtain the fire safety of railway car. The amount of toxic gases moved into the FT-IR gas cell via sampling line from the ISO 5659 chamber using cone heater was measured and compared the results for each materials.

  • PDF

LCD 패널 세척공정에서 원적외선 히터에 의한 유리기판 승온시간 예측 (Prediction of Heat-Up Time of the Glass Plate by IR Heaters in an LCD-Panel Cleaning Process)

  • 김윤호;지태호;김서영;리광훈
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.526-533
    • /
    • 2006
  • The prediction of heat-up time of an LCD glass plate in LCD glass pre-treatment process has been implemented in the present study. Firstly, the analytical solution for one-dimensional radiation heat transfer from IR heaters to a LCD glass plate is obtained. When the surface temperature of the IR heaters is set at 473 K, the heat-up time of LCD glass to averaged temperature of 383K is 28 seconds. In addition, a three dimensional full CFD analysis using STAR-CD is implemented in an effort to consider the effect of 3-D heat loss through the furnace walls. From the results of the 3-D CFB analysis, the heat-up time increases up to 32.5 seconds under the same conditions. When the IR heater temperature in creases up to 573 K, the heat-up time decreases to 12 seconds for the one-dimensional analytical solution and to 13.5 seconds for the 3-D CFD analysis, respectively.

고온, 고전압용 SiC 마이크로 히터 설계, 제작 및 특성 (Design fabrication and characteristics of 3C-SiC micro heaters for high temperature, high powers)

  • 정재민;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.113-113
    • /
    • 2009
  • This paper describes the characteristics of a poly 3C-SiC micro heater which was fabricated on $AlN(0.1{\mu}m)/3C-SiC(1.0{\mu}m)$ suspended membranes by surface micro- machining technology. The 3C-SiC and AlN thin films which have wide energy bandgap and very low lattice mismatch were used sensors for high temperature and voltage environments. The 3C-SiC thin film was used as micro heaters and temperature sensor materials simultaneously. The implemented 3C-SiC RTD (resistance of temperature detector) and the power consumption of micro heaters were measured and calculated. The TCR (thermal coefficient of the resistance) of 3C-SiC RTD is about -5200 $ppm/^{\circ}C$ within a temperature range from $25^{\circ}C$ to $50^{\circ}C$ and -1040 $ppm/^{\circ}C$ at $500^{\circ}C$. The micro heater generates the heat about $500^{\circ}C$ at 10.3 mW. Moreover, durability of 3C-SiC micro heaters in high voltages is better than pt micro heaters. A thermal distribution measured and simulated by IR thermovision and COMSOL is uniform on the membrane surface.

  • PDF

3C-SiC 마이크로 히터의 제작과 그 특성 (Fabrication of 3C-SiC micro heaters and its characteristics)

  • 정귀상;정재민
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.311-315
    • /
    • 2009
  • This paper describes the characteristics of a poly 3C-SiC micro heater which was fabricated on AlN(0.1 $\mu$m)/3C-SiC(1.0 $\mu$m) suspended membranes by surface micro-machining technology. The 3C-SiC and AlN thin films which have wide energy band gap and very low lattice mismatch were used sensors for high temperature and voltage environments. The 3C-SiC thin film was used as micro heaters and temperature sensor materials simultaneously. The implemented 3CSiC RTD(resistance of temperature detector) and the power consumption of micro heaters were measured and calculated. The TCR(thermal coefficient of the resistance) of 3C-SiC RTD is about -5200 ppm/$^{\circ}C$ within a temperature range from 25 $^{\circ}C$ to 50 $^{\circ}C$ and -1040 ppm/$^{\circ}C$ at 500 $^{\circ}C$. The micro heater generates the heat about 500 $^{\circ}C$ at 10.3 mW. Moreover, durability of 3C-SiC micro heaters in high voltages is better than Pt micro heaters. A thermal distribution measured and simulated by IR thermovision and COMSOL is uniform on the membrane surface.

EHC 기반 Urea-SCR 시스템 히터 표면온도 분포의 1-D 모델링 (1-D Modeling of Heater Surface Temperature Distribution in EHC-based Urea-SCR System)

  • 박선홍;손지현;문석수;오광철;장성욱;박성서
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.11-17
    • /
    • 2022
  • In upcoming Post Stage-V and Tier 5 regulations of construction machineries, nitrogen oxide (NOx) emissions are strictly limited in cold start conditions. In response to this, a method of improving NOx conversion efficiency has been applied by installing an electric heating catalyst (EHC) in front of conventional urea-SCR systems so that the evaporation and thermal decomposition of urea-water solution can be promoted in cold start conditions. In this strategy, the evaporation and thermal decomposition of urea-water solution and corresponding NOx conversion efficiency are governed by temperature conditions inside the EHC. Therefore, characterizing the temperature distribution in the EHC under various operating conditions is crucial for the optimized operation and control of the EHC in Urea-SCR systems. In this study, a 1-D modeling analysis was performed to predict the heater surface temperature distribution in EHC under various operating conditions. The reliability of prediction results was verified by comparing them with measurement results obtained using an infrared (IR) camera. Based on 1-D analysis results, the effects of various EHC operation parameters on the heater surface temperature distribution were analyzed and discussed.

유한요소해석을 통한 현장 가열 재활용 시공 장비의 가열판 용량에 따른 아스팔트 포장의 열전도성 평가 (Finite Element Analysis of Heat Transfer Effects on Asphalt Pavement Heated by Pre-Heater Unit Used in Hot In-Place Recycling)

  • 이강훈;임진선;정규동;임정혁;권수안;김용주
    • 한국도로학회논문집
    • /
    • 제18권2호
    • /
    • pp.73-82
    • /
    • 2016
  • PURPOSES: The national highways and expressways in Korea constitute a total length of 17,951 km. Of this total length of pavement, the asphalt pavement has significantly deteriorated, having been in service for over 10 years. Currently, hot in-place recycling (HIR) is used as the rehabilitation method for the distressed asphalt pavement. The deteriorated pavement becomes over-heated, however, owing to uncontrolled heating capacity during the pre-heating process of HIR in the field. METHODS: In order to determine the appropriate heating method and capacity of the pre-heater at the HIR process, the heating temperature of asphalt pavement is numerically simulated with the finite element software ABAQUS. Furthermore, the heating transfer effects are simulated in order to determine the inner temperature as a function of the heating system (IR and wire). This temperature is ascertained at $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$, and $800^{\circ}C$ from a slab asphalt specimen prepared in the laboratory. The inner temperature of this specimen is measured at the surface and five different depths (1 cm, 2 cm, 3 cm, 4 cm, and 5 cm) by using a data logger. RESULTS: The numerical simulation results of the asphalt pavement heating temperature indicate that this temperature is extremely sensitive to increases in the heating temperature. Moreover, after 10 min of heating, the pavement temperature is 36%~38% and 8%~10% of the target temperature at depths of 25 mm and 50 mm, respectively, from the surface. Therefore, in order to achieve the target temperature at a depth of 50 mm in the slab asphalt specimen, greater heating is required of the IR system compared to that of the gas. CONCLUSIONS : Numerical simulation, via the finite element method, can be readily used to analyze the appropriate heating method and theoretical basis of the HIR method. The IR system would provide the best heating method and capacity of HIR heating processes in the field.

시험용 달 궤도선의 광학탑재체 시스템 열설계에 대한 수치해석적 연구 (Numerical Study on the Thermal Design of Lunar Terrain Imager System Loaded on the Korea Pathfinder Lunar Orbiter)

  • 김택영;장수영;허행팔
    • 한국항공우주학회지
    • /
    • 제47권4호
    • /
    • pp.309-318
    • /
    • 2019
  • 한국형 달 궤도선(Korea Pathfinder Lunar Orbiter, KPLO)에 탑재되는 달 표면지형 광학관측기(Lunar Terrian Imager, LUTI)의 열설계를 수행하고, 열해석을 통하여 열설계의 건전성을 검증하였다. 달 임무궤도의 열환경은 지구궤도와 달리 달 표면의 IR 복사가 중요하므로 이를 열설계에 반영하여야 한다. 위성 외부에 노출되는 부품이나 모듈은 가능한 MLI로 단열시키지만 경통이나 방열판은 기능상 노출되므로 복사형상계수의 개념을 이용한 thermal shield를 전면에 장착함으로써 IR 복사를 완화시킨다. 태양복사를 거의 받지 않는 방열판의 전면부는 IR 방사율이 중요하며, 경통과 같이 열변형에 취약한 부품은 복사히터를 사용하여 온도구배를 최소화시킨다. 열해석 결과분석을 통하여 LUTI의 열설계는 다양한 상황에서 안정적임을 확인하였다.

미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징 (Low Temperature Hermetic Packaging by Localized Heating using Micro Heater)

  • 심영대
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 추계기술심포지움논문집
    • /
    • pp.15-19
    • /
    • 2002
  • 기존 형상의 미세 가열기를 이용한 마이크로 시스템 패키징의 문제점을 해결하기 위해 새로운 형상의 미세 가열기를 제작하여 패키징 실험을 실시하였다. 기존 형상의 미세 가열기와 새로운 미세 가열기의 형상을 각각 제작하여 접합시에 미세 가열기에 발생하는 열분포를 IR 카메라를 이용하여 실험하였다. 기존 형상의 미세 가열기가 불균일하게 가열되는 반면, 새로운 형상의 미세 가열기는 매우 균일하게 가열되는 형상을 나타내었다. IR 카메라 실험을 바탕으로 접합 실험을 실시하였다. 접합 실험시 사용한 미세 가열기는 폭 50$\mu\textrm{m}$, 두께 2$\mu\textrm{m}$로 제작하였으며, 0.2 Mpa의 압력을 Pyrex glass cap에 가한 상태에서 150 mA의 전류를 공급함으로서 접합을 완료하였다. 접합이 완료된 시편들에 대해서 IPA를 통한 leakage 실험을 실시하였으며, 기존 형상의 미세 가열기를 이용한 시편들은 66%가 테스트를 통과한 반면 새로운 형상의 미세 가열기를 이용한 시편들은 85% 이상이 테스트를 통과하였다. Leakage 실험을 통과한 각각의 시편들에 대해서 접합력 측정을 실시한 결과, 기존 형상의 미세 가열기를 이용한 시편들은 15~21 Mpa의 접합력을 나타내었고, 새로운 형상의 미세 가열기를 이용한 시편들은 25~30 Mpa의 우수한 접합력을 나타내었다.

  • PDF

하나로 표준형 계장 캡슐의 열적성능 평가

  • 주기남;박종만;맹완영;강영환
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(2)
    • /
    • pp.415-420
    • /
    • 1997
  • 하나로 재료 조사시험용 표준형 계장캡슐 개발의 일환으로 캡슐 mock-up (96M-01K)을 제작하여 노외에서 승온 성능실험을 수행함으로써, 실제 하나로내 장입시의 거동 및 안전성을 평가하고자 하였다. 본 실험을 통하여 표준형 계장캡슐의 설계/제작기술, 열적조절성능, 그리고 열설계용 컴퓨터 code (GENGTC) 둥을 평가할 수 있었다. 캡슐의 진공 및 micro-heater system은 만족할만한 성능을 보였으며, 캡슐의 공기중 승은거동은 계산치와 약간의 차이는 있으나, 이는 가공/조립상의 내부 gap 변화, 캡슐표면에서의 온도측정상의 오류, 그리고 상하부로의 열손실 등에 기인하는 것으로 추정된다. 본 실험을 통하여 표준형 계장캡슐의 하나로내 건전성을 추정할 수 있었으며, 향후 하나로 장입시의 승온 및 하강절차 등을 설정할 수 있었다. 현재 본 실험 결과들을 토대로 하나로 조사시험공의 (CT, IR1, IR2) 핵적특성 평가용 표준형 계장캡슐을 (97M-01K) 설계ㆍ제작 중이다.

  • PDF

열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법 (Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography)

  • 권성준;박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.40-48
    • /
    • 2012
  • 콘크리트내의 철근의 부식은 열화와 콘크리트 구조물의 조기파괴의 주된 원인이 된다. 본 연구에서는 비파괴 기법 중 전자기적 열유도방법과 적외선 열화상기법을 이용한 철근부식평가가 시도되었는데, 부식 또는 비부식된 철근의 열특성 차이를 이용한 것이다. 본 논문은 이러한 개념을 배경으로 수행한 실험적 연구이며, 유도전류를 통해 콘크리트 표면으로부터 내부 철근을 가열하고 외부의 적외선 카메라를 이용하여 표면의 온도변화를 관측한다. 피복두께가 다른 콘크리트 시편은 앞면과 배면의 피복두께를 동일하게 제조하여 앞면에서 가열과 배면에서의 온도측정을 동시에 할 수 있도록 고안되었다. IC (Impressed Current) 방법을 통하여, 철근 부식을 촉진하였으며, 적외선 화상을 통하여 온도가열과 냉각을 전 시험과정에 걸쳐 측정하였다. 본 실험을 통하여 부식/비부식 철근의 뚜렷한 온도변화를 확인하였으며, 부식된 시편에서 빠른 온도증가속도 및 냉각속도를 평가하였다. 본 연구는 콘크리트 매립철근의 비파괴적인 부식탐지의 가능성을 보여주고 있다.