• 제목/요약/키워드: IR-Thermography

검색결과 60건 처리시간 0.027초

족삼리(足三里) (ST36) 자침(刺鍼)이 안면부(顔面部) 한열변화(寒熱變化)에 미치는 영향(影響) (Characteristics of Acupuncture at ST36 on Facial Thermography of Health Subject)

  • 김영태;김재효;황재호;김경식;손인철
    • Korean Journal of Acupuncture
    • /
    • 제19권2호
    • /
    • pp.13-33
    • /
    • 2002
  • This study was examined for effects of acupuncture of Zusanli (ST36) on the facial thermography in health subjects. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature (23-$25^{\circ}C$) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of face was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 min before, just before and 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to the left ST36 for 30 mins. The results showed that acupuncture of ST36 significantly decreased the temperature of all the areas of facial surface comparing to those of control group. Also, it was observed that the quantities of thermal changes following acupuncture of ST36 been increased significantly at the A1, A4, A6, A7 and A9 ROIs (region of interest) comparing that of control group. Observed the thermography classified by ROI, it was clear the fact that acupuncture of ST36 could modulate the specific areas concerning to the facial pathway of Stomach Meridian, because the thermal responses following acupuncture of ST36 were specific at the A1, A2, A5 and A9 ROIs, relatively. These results suggest that acupuncture of ST36 may modulate thermal distributions and changes of facial areas concerned with Stomach Meridian.

  • PDF

적외선 열화상을 이용한 비파괴시험 활용 및 결함 진단 (The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography)

  • 최만용;김원태
    • 비파괴검사학회지
    • /
    • 제24권5호
    • /
    • pp.525-531
    • /
    • 2004
  • 본 고는 적외선 열화상의 개념과 적외선열화상 측정윈리 및 카메라 셋팅을 기술하고 적외선열화강(IRT)에 의한 비파괴검사(NDT)의 활용 및 비파괴검사의 진단에 대하여 살펴보았다. 적외선 열화상은 주어진 표면을 따라 온도에 관련된 열패턴의 평가를 통한 정기적인 비접촉, 비파괴 시험의 수행으로 초기에 장비 고장의 예방이 가능하다. 진단 활용으로서, 열적으로 가열된 내부결함이 있는 블록에 대하여 적외선열화상을 이용한 열화상 패턴을 비파괴 기법으로 평가하고, 결함과 열화상패턴간의 특성을 분석하여 열화상 평가 기법에 대하여 논하였다.

Thermography-based coating thickness estimation for steel structures using model-agnostic meta-learning

  • Jun Lee;Soonkyu Hwang;Kiyoung Kim;Hoon Sohn
    • Smart Structures and Systems
    • /
    • 제32권2호
    • /
    • pp.123-133
    • /
    • 2023
  • This paper proposes a thermography-based coating thickness estimation method for steel structures using model-agnostic meta-learning. In the proposed method, a halogen lamp generates heat energy on the coating surface of a steel structure, and the resulting heat responses are measured using an infrared (IR) camera. The measured heat responses are then analyzed using model-agnostic meta-learning to estimate the coating thickness, which is visualized throughout the inspection surface of the steel structure. Current coating thickness estimation methods rely on point measurement and their inspection area is limited to a single point, whereas the proposed method can inspect a larger area with higher accuracy. In contrast to previous ANN-based methods, which require a large amount of data for training and validation, the proposed method can estimate the coating thickness using only 10- pixel points for each material. In addition, the proposed model has broader applicability than previous methods, allowing it to be applied to various materials after meta-training. The performance of the proposed method was validated using laboratory-scale and field tests with different coating materials; the results demonstrated that the error of the proposed method was less than 5% when estimating coating thicknesses ranging from 40 to 500 ㎛.

Sharp Fin에 의한 초음속 유동장내 열전달 변화 연구 (A Study of Heat Transfer in Supersonic Flow Field on a Sharp Fin Shape)

  • 송지운;유만선;조형희
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.371-374
    • /
    • 2006
  • 초음속 유동장 내에서 돌출된 sharp fin형상에 의해 발생하는 충격파로 인한 열전달 특성변화 연구를 수행하였다. IR camera를 이용하여 마하 3의 유동 내에 attack angle이 $10^{\circ}$ 부터 $20^{\circ}$ 의 fin을 돌출시켜 생기는 충격파에 의한 바닥면 열전달 계수 변화를 측정하였으며, 유동장의 변화를 알아보기 보기 위해 oil flow method를 사용하였다.

  • PDF

적외선을 이용한 비파괴검사 기술 (Nondestructive Testing Technique using Infrared Thermography)

  • 박문호;이익환
    • 비파괴검사학회지
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 1995
  • 적외선을 이용한 비파괴검사 방법은 검사자가 검사체의 온도를 분석하여 검사체의 건전성을 평가할 수 있도록 개발된 방법이다. 이것이 최근에는 화력발전소 및 원자력발전소 등과 같은 다양한 산업에 적용되어 사용되고 있다. 따라서, 본 보고서는 적외선을 이용한 비파괴검사의 기초적인 원리, 적외선 측정 장비의 기본 원리 및 그것의 응용분야를 기술하였다.

  • PDF

UV-IR 카메라를 이용한 전력설비 진단을 위한 전기 및 광학적 안전 기준 설정 연구 (A Study of Electrical and Optical Method of Safety Standards for diagnosis of Power Facility using UV-IR Camera)

  • 김영석;김종민;최명일;방선배;송길목;곽동순
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.54-61
    • /
    • 2013
  • UV-IR camera is being used for predictive maintenance of high voltage equipment together with measurement of temperature on localized heat and corona discharge. This paper was suggested the judgement method that is the discharge count, UV image pattern and discharge matching rate to apply the UV-IR camera on power facility. The discharge count method is counted by UV image pixel value. the UV image pattern method is determined by the UV image shape using neural network algorithm method, separated by Sunflower, Jellyfish, Ameba. The UV discharge matching is compare the breakdown the UV image size and measuring UV image size according to distance.

고온 환경에서의 적외선 열화상 측정에 관한 연구 (Research on Measurement of Infrared Thermograpphy under High Temperature Condition)

  • 이준식;전재욱
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

체표온도특성(體表溫度特性)과 맥율(脈率)의 상관성(相關性) 연구(硏究) (A Study of Correlation between Pulse-Respiration Ratio and Characteristics of Thermal Temperature)

  • 이혁재;박영재;박영배;오환섭
    • 대한한의진단학회지
    • /
    • 제12권1호
    • /
    • pp.103-130
    • /
    • 2008
  • Background: For standardizing of Han-Yeol [寒熱], which is a kind of diagnosis method in oriental medicine, it is necessary to investigate into relationship of symptoms and signs representative of Han-Yeol [寒熱] to the biofunctional medical signals; thermal temperature by Thermography, Pulse-Respiration Ratio and so on. By correlation analysis of these data items acquired from patients, it could be provides the fundamental data for standardizing of Han-Yeol [寒熱]. Objectives: We performed this study to check the characteristics of thermal temperature with Han-Yeol [寒熱] statue by pulse-respiration ratio. Methods: We selected nine regions around acupoints including Yin dang[印堂], Sugu[水溝, GV26], Ch'ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Chonchu[天樞 S25], No-gung[勞官, P8], and calculated based on the utility of R.O.I.(Region of Integer) by IR-2000 these points temperature from 68 subjects. In practicing pulse-respiration ratio over 4.0 means the statues of Yeol [熱], pulse-respiration ratio below 4.0 means the statues of Han [寒]. To optimum conditions thermal temperature, which are not effected by internal and external variables, we studied preceding research. The results shows that optimal time period is 20minutes after undressed and the optimal region is the region around acupoints including Sugu [水溝, GV26]. Based on a preceding research results, we analyzed these data by Paired T-test between GV26 Region and 8-Thermography Regions and two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio. Results: 1. In applying of two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio, Sugu [水溝穴, GV26] - [印堂穴, HN1], Sugu 水溝, GV26] - Chonjung[CV17], Sugu [水溝, GV26] -Chung-wan[中脘, CV12]had significant differences. 2. In applying of Paired T-test between Sugu [水溝穴, GV26] Region and 8- Thermography Regions, there were significant differences except of Sugu [水溝穴, GV26] -Chondolp[天突, CV22]. 3. In the difference of Sugu [水溝, GV26] -Chung-wan[中脘, CV12], thermal temperature increases a lot in the statues of Yeol [熱], thermal temperature decreases a lot in the statues of Han [寒]. Conclusions: On the analysis of Thermography, we obtain the measurement conditions were considered the individual variations. And it is different that the thermal temperature change on Thermography according to Han-Yeol [寒熱] statue by pulse-respiration ratio.

  • PDF

위상잠금 열화상 기법의 최적 실험 조건 탐색 연구 (An Exploratory Study on the Optimized Test Conditions of the Lock-in Thermography Technique)

  • 조용진
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.157-164
    • /
    • 2011
  • 위상잠금 적외선 열화상(lock-in infrared thermography) 기법의 조선해양공학 분야에 적용 가능성을 검토하였다. 이를 위해 실험계획법에 의해 향상된 결함부와 건전부의 위상차 대비영상을 얻기 위한 탐색 연구를 수행하였다. 위상차 대비영상의 평가를 정량회하기 위하여 대비 기준표와 홀 크기에 가중치를 주는 방법을 적용하여 유용한 판별기준임을 입증하였다. 그리고 표면에 광 조사 세기는 중간이나 낮은 조사량이 좋은 결과를 보여주고, 높은 조사는 유용한 결과를 주지 못했다. 위상잠금 주파수는 가진 광원의 세기에 비례하여 좋은 결과를 획득할 수 있었고, 열화상 카메라의 노출시간(integration time)은 조사 광원의 세기와 반비례하여 실험을 수행하는 것이 좋은 결과를 얻을 수 있었다. 그러나 시험편(specimen)의 차이는 약간의 편향된 결과를 얻었지만 유의하지는 못했다.

적외선 열화상 기술을 이용한 복합재료의 결함 검출 정량화 연구 (Study on the Qualitative Defects Detection in Composites by Optical Infrared Thermography)

  • 박희상;최만용;박정학;김원태;최원종
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.150-156
    • /
    • 2011
  • 본 논문에서는 현재 산업 전반에 널리 사용되고 있는 복합재료(탄소섬유강화플라스틱, 유리섬유강화플라스틱)의 비파과검사를 위한 광적외선 열화상기법을 이용한 복합재료 측정 표준기술개발을 위한 결함(인클루젼, 충간결함) 검출 기술을 실험하였다. 결함의 검출률을 높이기 위하여 위상잠금 방법을 활용하였다. 결과는 시험편의 두께에 따라 광원의 조사시간을 늘릴 경우 결함 검출의 확률이 높아진다는 것을 알 수 있다. 하지만 50 mHz 이하의 광원을 가하였을 때에도 결과값이 좋아지지 않는 점은 열확산이 재료 전체에 영향을 미치게 되면 결함 부위가 전체적으로 열평형 상태가 되어 결함 검출이 어려움을 파악할 수 있었다.