• Title/Summary/Keyword: IR method

Search Result 1,742, Processing Time 0.033 seconds

Expression of Vascular Endothelial Growth Factor Protein in Astrocytic Tumors (성상세포종에서 혈관내피세포 성장인자의 발현)

  • Park, Se-Hyuck;Chang, In-Bok;Kim, Chang-Hyun;Cho, Young-Jun;Cho, Byung-Moon;Shin, Dong-Ik;Oh, Sae-Moon;Kim, Duk-Whan;Nam, Eun-Sook
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.6
    • /
    • pp.683-687
    • /
    • 2001
  • Objective : Angiogenesis, the proliferation of capillary endothelial cells, is a vital component in the development, progression, and metastasis of many human tumors. Vascular endothelial growth factor(VEGF) is an endothelial cell-specific mitogen and induces angiogenesis and vascular permeability. The features of glioblastoma, distinct from low grade astrocytomas, are the presence of necroses and vascular endothelial proliferation. In this study, we investigated VEGF expression in the different grades of astrocytomas and determined whether VEGF expression correlates with development of glioblastoma and progression of astrocytomas. Patients and Methods : Forty seven patients with astrocytic tumors(24 males and 23 females), aged 3 to 65 years, were evaluated. Immunohistochemical staining was carried out using labelled streptavidin biotin method and primary antibody was a antirabbit polyclonal Ab against N-terminus region of VEGF165(Oncogene research product, MA, USA). Immunoreactivity(IR) was classified into no IR(absent or a trace of stain), moderate IR and intense IR by level of staining amount and intensity. Results : Six pilocytic astrocytomas showed 3 no IR and 3 moderate IR, 10 astrocytomas showed 2 no IR, 6 moderate IR and 2 intense IR, 12 anaplastic astrocytomas showed I no IR, 7 moderate IR and 4 intense IR and 19 glioblastomas showed 1 no IR, 11 moderate IR and 7 intense IR. Immunoreactivity was significantly different between low and high grade of tumors but there was no significant difference between anaplastic astrocytomas and glioblastomas. Gemistocytic tumor cells represented the predominent VEGF-immunoreactive cell types, as compared with compactly-arranged small tumor cells. In glioblastomas VEGF IR was observed in both perinecrotic and vital tumor areas. Conclusion : VEGF seems to be a important angiogenic factor in anaplastic astrocytomas and glioblastomas and VEGF expression may contribute to neovascularization of human astrocytomas.

  • PDF

Immunohistochemical Study of the Endocrine Cells in the Pancreas of the Korean Aucha Perch, Serranidae (Coreoperca herzi) (Serranidae (Coreoperca herzi) 췌장 내분비세포에 대한 면역조직화학적 연구)

  • Lee, Jae-hyun;Ku, Sae-kwang;Lee, Hyeung-sik;Ham, Tae-su
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.339-347
    • /
    • 2003
  • The regional distribution and relative frequency of some endocrine cells in the pancreas of the Korean aucha perch, Coreoperca herzi Herzenstein belonging to the family Serranidae in order Perciformis, were observed using specific mammalian antisera against serotonin, insulin, glucagon, somatostatin and human pancreatic polypeptide (hPP) by peroxidase antiperoxidase (PAP) method. The pancreas was divided into four portions (principal and secondary islets, exocrine and pancreatic duct regions). In addition, the pancreatic islet regions were further subdivided into three regions (central, mantle and peripheral regions). Spherical to spindle or occasionally round to oval immunoreactive (IR) cells were demonstrated in the pancreatic islets and exoccrine portions, but no cells were detected in the pancreatic duct portions. In the principal islets, serotonin-IR cells were not detected but most of insulin-IR cells were located in the central regions and they were also demonstrated in the mantle and peripheral regions in moderate and rare frequencies, respectively. Glucagon- and hPP-IR cells were mainly situated in the mantle regions but the cells were also demonstrated in the peripheral regions in relatively lower frequency. Somatostatin-IR cells were evenly distributed in the central and mantle regions in a few frequency and cells were also demonstrated in the peripheral regions in rare frequency. Cell clusters were consisted of hPP-IR cells that were situated in the peripheral to mantle regions. In the secondary islet portions, serotonin-IR cells were randomly distributed throughout the whole pancreatic islet regions but lower frequency was detected in the peripheral regions compared to that in central and mantle regions where cells were detected in a few frequency, respectively. Insulin-IR cells were restricted to the central regions in numerous frequency and glucagon-IR cells were evenly distributed in the mantle and peripheral regions in moderate frequencies, respectively. Somatostatin-IR cells were observed in the central and mantle regions in moderate and a few frequencies, respectively. In addition, hPP-IR cells showed similar distributional patterns to those of glucagon-IR cells except cells were also located in the central regions in rare frequency. In the exocrine portions, only glucagon- and hPP-IR cells were demonstrated in rare and a few frequencies, respectively. In conclusion, the regional distribution and relative frequency of pancreatic endocrine cells of the Korean aucha perch showed general patterns, which were observed in other teleost. However, some species-dependent different distributional patterns and/or relative frequencies were also demonstrated especially to serotonin-IR cells. In pancreas of the Korean aucha perch, insulin-IR cells were the most predominant cell type followed by glucagon-, somatostatin-, hPP- and serotonin-IR cells.

Optimization of Corrosion Properties of Ti/TiO2/IrO2-RuO2 Electrodes via Taguchi Method (Taguchi법을 이용한 Ti/TiO2/IrO2-RuO2전극의 부식특성 최적화)

  • 이득용;채경선;최형기;예경환;안중홍;송요승
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.6
    • /
    • pp.582-588
    • /
    • 2002
  • IrO$_2$-RuO$_2$ films were deposited on plasma sprayed TiO$_2$ buffer layer above Ti metal by sol-gel and dip-coating method. Organic vehicle (ethyl cellulose and $\alpha$-terpineol) and glass frit were added to improve adherence of the coatings. Taguchi method and L$_{18}$ (2$^1$$\times$3$^{7}$ ) orthogonal arrays were evalvated in terms of current density to determine the optimal combination of levels of factors that best satisfy the bigger is better quality characteristic. The observed conditions were as fellows: ethyl cellulose (100 cp), drying temperature and time (17$0^{\circ}C$,20 min), heat treatment temperature and time (75$0^{\circ}C$,10 min), the weight ratio of IrO$_2$-RuO/powders to glass frit (99:5), final heat treatment time (120 min) and flow rate of air (5 sccm), respectively. ANOVA analysis suggested that the influence of the factors within $\alpha$= 0.1 was significant with a 90% confidence level.

Investigation of the Green Emission Profile in PHOLED by Gasket Doping

  • Park, Won-Hyeok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.226-226
    • /
    • 2016
  • PHOLED devices which have the structure of ITO/HAT-CN(5nm)/NPB(50nm)/EML(30nm)/TPBi(10nm)/Alq3(20nm)/LiF(0.8nm)/Al(100nm) are fabricated to investigate the green emission profile in EML by using a gasket doping method. CBP and Ir(ppy)3 (2% wt) are co-deposited homogeneously as a background material of EML for green PHOLED, then a 5nm thickness of additionally doped layer by Ir(btp)2 (8% wt) is formed as a profiler of the green emission. The total thickness of the EML is maintained at 30nm while the distance of the profiler from the HTL/EML interface side (x) is changed in 5nm steps from 0nm to 25nm. As shown in Fig. 1, the green (513nm) peak from Ir(ppy)3 is not observed when Ir(btp)2 is also doped homogeneously because Ir(ppy)3 works as an gasket dopant of the Ir(btp)2 :CBP system. Therefore, in this experment, Ir(btp)2 can be used as a profiler of the green emission in CBP:Ir(ppy)3 system. The emission spectra from the PHOLED devices with different x are shown in Fig. 2. In this gasket doping system, stronger red peak means more energy transfer from green to red dopant or higher exciton density by green dopant. To find the green emission profile, the external quantum efficiency (EQE) at 3mA/cm2 for red peaks are calculated. More green light emission at near EML/HBL interface than that of HTL/EML is observed (insert of Fig. 2). This means that the higher exciton density at near EML/HBL interface in homogeneously doped CBP with Ir(ppy)3. As shown in Fig. 3, excitons can be quenched easily to HTL(NPB) because the T1 level of HTL(2.5eV) is relatively lower than that of EML(2.6eV). On the other hand, the T1 level of HBL(2.7eV) is higher than that of EML.

  • PDF

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

Quantitative Mass Spectrometric Analysis of Mixed Self-Assembled Monolayers for Biochips

  • Son, Jin Gyeong;Shon, Hyun Kyong;Hong, Daewha;Choi, Changrok;Han, Sang Woo;Choi, Insung S.;Lee, Tae Geol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.275-275
    • /
    • 2013
  • Formation and characterization of self-assembled monolayers (SAMs) on various surfaces are the essential basis for many other applications, including molecular switches, biosensors, microfluidics, and fundamental studies in surfaces and interfaces. To improve the performance at these applications, it is a key to control the quantity of each molecule in various mixed SAMs on the surface. In this study, using mixed SAM of carbamate-based hydroquinone (HQ)-PhBr and11-mercaptoundecanol, the quantitative mass spectrometric method of mixed SAM was developed based on comparison study with XPS and FT-IR methods. In addition, our method was applied to another mixed SAM of biotinylated PEG alkane thiol and 11-mercaptoundecanol for verification purpose. Time-of-flight secondary mass spectrometry (ToF-SIMS) analysis was performed to identify and quantify each molecule of mixed SAM along with principal component analysis (PCA). Since there is no matrix effect in the X-ray photoelectron spectroscopy (XPS) and Fourier transform-infrared (FT-IR) techniques, we compared ToF-SIMS results with XPS and FT-IR results. Because PCA results from ToF-SIMS analysis are well matched with XPS and FT-IR results from both mixed SAMs, we are expecting that our method will be useful to identify and quantify each molecule in various mixed SAMs.

  • PDF

Effect of Size Factor on Estimating Elastic Modulus of Disk-Shaped Concrete Specimen Using Impact Resonance Test (충격공진법을 이용한 콘크리트 원판 시편의 탄성계수 추정에 크기 인자가 미치는 영향)

  • Kim, Min-Suk;Son, Joeng Jin;Lee, Chang Joon;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.11-22
    • /
    • 2023
  • In this work, a depth-by-depth evaluation on the deterioration of concrete is suggested by utilizing disk shaped concrete specimens. Dynamic elastic modulus of cylindrical concrete was measured using a free-free resonance column method and compared with dynamic elastic modulus of disk-shaped concrete measured by impulse excitation technique(IET) and impact resonance(IR). According to the results of the experiment, both IET and IR methods showed a smaller difference in dynamic elastic modulus with smaller deviation in data when thickness of the disk specimen was increased. This trend was more evident from dynamic elastic modulus measured by IR method compared to that measured by IET. Variation in data was also smaller with the IR result. To increase the accuracy of the data, it is recommended to use the IR method for disk specimen with a diameter of 100mm and a thickness of 25mm.

Analysis of MWIR and LWIR Signature of Supersonic Aircraft to Air-to-air and Surface-to-air Missile by Coupled Simulation Method (통합해석기법을 활용한 공대공 및 지대공 적외선 미사일 대응 초음속 항공기의 중적외선 및 원적외선 신호 분석)

  • Kim, Taehwan;Bae, Ji-Yeul;Kim, Taeil;Jung, Daeyoon;Hwang, Chang Su;Cho, Hyung Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.764-772
    • /
    • 2014
  • The stealth performance of supersonic aircraft in recent air battlefield is one of the most significant feature for latest fighters. Especially, as the technology is advancing, the IR stealth capability becomes more important because of its passive characteristic. To design an aircraft with stealth capability, we must know how much the IR signature is generated from the aircraft. Also, predicting the IR signature of enemy's aircraft is tactically crucial. In this study, we calculated MWIR and LWIR infrared signature of $5^{th}$ generation supersonic aircraft against air-to-air and surface-to-air threat using IR simulation code and CFD coupled procedure.

Infrared Light Absorbance: a New Method for Temperature Compensation in Nondispersive Infrared CO2 Gas Sensor

  • Yi, Seung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.303-311
    • /
    • 2020
  • Nondispersive infrared CO2 gas sensor was developed after the simulation of optical cavity structure and assembling the optical components: IR source, concave reflectors, Fresnel lens, a hollow disk, and IR detectors. By placing a hollow disk in front of reference IR detector, the output voltages are almost constant value, near to 70.2 mV. The absorbance of IR light, Fa, shows the second order of polynomial according to ambient temperatures at 1,500 ppm. The differential output voltages and the absorbance of IR light give a higher accuracy in estimations of CO2 concentrations with less than ± 1.5 % errors. After implementing the parameters that are dependent upon the ambient temperatures in microcontroller unit (MCU), the measured CO2 concentrations show high accuracies (less than ± 1.0 %) from 281 K to 308 K and the time constant of developed sensor is about 58 sec at 301 K. Even though the estimation errors are relatively high at low concentration, the developed sensor is competitive to the commercial product with a high accuracy and the stability.

Using Design of Mixture Experiments to Select the Ratio of a Three-Component Electrode for Optimal Generation of Hydroxyl Radicals (혼합물 실험계획법을 이용한 OH라디칼 최적 생성을 위한 삼성분 전극의 비율 선정)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.793-800
    • /
    • 2020
  • The conventional development of multi-component electrodes is based on the researcher's experience and is based on trial and error. Therefore, there is a need for a scientific method to reduce the time and economic losses thereof and systematize the mixing of electrode components. In this study, we use design of mixture experiments (DOME)- in particular a simplex lattice design with Design Expert program- to attempt to find an optimum mixing ratio for a three-component electrode for the high RNO degradation; RNO is an indictor of OH radical formation. The experiment included 12 experimental points with 2 center replicates for 3 different independent variables (with the molar ratio of Ru, Ti, Ir). As the Prob > F value of the 'Quadratic' model is 0.0026, the secondary model was found to be suitable. Applying the molar ratio of the electrode components to the corrected response model results is an RNO removal efficiency (%) = 59.89 × [Ru] + 9.78 × [Ti] + 67.03 × [Ir] + 66.38 × [Ru] × [Ir] + 132.86 × [Ti] × [Ir]. The R2 value of the equation is 0.9374 after the error term is excluded. The optimized formulation of the ternary electrode for an high RNO degradation was acquired when the molar ratio of Ru 0.100, Ti 0.200, Ir 0.700 (desirability d value, 1).