• Title/Summary/Keyword: IR laser

Search Result 200, Processing Time 0.024 seconds

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF

Performance Evaluation of Mid-IR Spectrometers by Using a Mid-IR Tunable Optical Parametric Oscillator (중적외선 광 파라메트릭 발진기를 이용한 중적외선 분광기 성능 평가)

  • Nam, Hee Jin;Kim, Seung Kwan;Bae, In-Ho;Choi, Young-Jun;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.4
    • /
    • pp.154-158
    • /
    • 2019
  • We have used a mid-IR (mid-infrared) continuous-wave (cw) optical parametric oscillator (OPO), developed previously and described in Ref. 12, to build a performance-evaluation setup for a mid-IR spectrometer. The used CW OPO had a wavelength tuning range of $ 2.5-3.6{\mu}m$ using a pump laser with a wavelength of 1064 nm and a fan-out MgO-doped periodically poled lithium niobate (MgO:PPLN) nonlinear crystal in a concentric cavity design. The OPO was combined with a near-IR integrating sphere and a Fourier-transform IR optical spectrum analyzer to build a performance-evaluation setup for mid-IR spectrometers. We applied this performance-evaluation setup to evaluating a mid-IR spectrometer developed domestically, and demonstrated the capability of evaluating the performance, such as spectral resolution, signal-to-noise ratio, spectral stray light, and so on, based on this setup.

Blind Via Hole Drilling Using DPSS UV laser (DPSS UV 레이저를 이용한 블라인드 비아 홀 가공)

  • 김재구;장원석;신보성;장정원;황경현
    • Laser Solutions
    • /
    • v.6 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • Micromachining using the DPSS 3rd Harmonic Laser (355nm) has outstanding advantages as a UV source in comparison with Excimer lasers in various aspects such as maintenance cost, maskless machining, high repetition rate and so on. It also has the greater absorptivity of many materials in contrast to other IR sources. In this paper, the process for micro-drilling of blind hole in Cu/PI/Cu substrate with the DPSS UV laser and the scanning device is investigated by the experimental methods. It is known that there is a large gap between the ablation threshold of copper and that of PI. We use the Archimedes spiral path for the blind hole with different energy densities to ablate the different material. Finally, the blind via hole of diameter 100$\mu\textrm{m}$ and 50$\mu\textrm{m}$ was drilled.

  • PDF

A STUDY OF QUALITY MONITORING SYSTEM FOR MANUFACTURING PROCESS AUTOMATION DURING LASER TAILORED BLANK WELDING

  • Park, Young-Whan;Park, Hyunsung;Sehun Rhee
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.606-611
    • /
    • 2002
  • Welding using lasers can be mass-produced in high speed. In the laser welding, performing real-time monitoring system of the welding quality is very important in enhancing the efficiency of welding. In this study, the plasma and molten metal which are generated during laser welding were measured using the UV sensor and IR sensors. The results of laser welding were classified into five categories such as optimal heat input, little low heat input, low heat input, partial joining due to gap mismatch, and nozzle deviation. Also, a system was formulated which uses the measured signals with a fuzzy pattern recognition method which is used to perform real-time evaluation of the welding quality and the defects which can occur in laser welding.

  • PDF

A study on the real time quality estimation in laser tailored blank welding (레이저 테일러드 브랭크 용접의 실시간 품질판단 및 통계프로그램에 관한 연구)

  • Park, Young-Whan;Rhee, Se-Hum;Park, Hyun-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.791-796
    • /
    • 2001
  • Welding using lasers can be mass-produced in high speed. In the laser welding, performing real-time evaluation of the welding quality is very important in enhancing the efficiency of welding. In this study, the plasma and molten metal which are generated during laser welding were measured using the UV sensor and IR sensor. The results of laser welding were classified into five categories such as optimal heat input, little low heat input, low heat input, focus off, and nozzle change. Also, a system was formulated which uses the measured signals with a fuzzy pattern recognition method which is used to perform real-time evaluation of the welding quality and the defects which can occur in laser welding. Weld quality prediction program was developed using previous weld results and statistical program which could show the trend of weld quality and signal was developed.

  • PDF

Micro Heater Trimming using UV Laser (UV레이저를 이용한 마이크로 히터 트리밍)

  • Yoo, Seungryeol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.36-40
    • /
    • 2017
  • In this paper, a new method of laser trimming of thick film heater is studied. Various laser waves (IR, Green, UV) are used to ablation the heater and the process parameters are also presented. For given initial printed resisters, the cutting length should be prepared to obtain the target resister value in advance. Therefore, the cutting model is very important. The well-known model was tested and proven that it is valid only within a certain range of cutting length. A new model is proposed for a wide range of resister laser trimming. The cutting lengths and resister variation was obtained and formulated. To verify the presented method, the cutting lengths of each resister are calculated for various target resister value and laser trimming using UV is conducted.

  • PDF

A Study of Quality Monitoring System for Manufacturing Process Automation during Laser Tailored Blank Welding

  • Park, Y.W.;Park, H.;Rhee, S.
    • International Journal of Korean Welding Society
    • /
    • v.3 no.1
    • /
    • pp.45-50
    • /
    • 2003
  • Welding using lasers can be mass-produced in high speed. In the laser welding, performing real-time monitoring system of the welding quality is very important in enhancing the efficiency of welding. In this study, the plasma and molten metal which are generated during laser welding were measured using the UV sensor and IR sensors. The results of laser welding were classified into five categories such as optimal heat input, little low heat input, low heat input, partial joining due to gap mismatch, and nozzle deviation. Also, a system was formulated which uses the measured signals with a fuzzy pattern recognition method which is used to perform real-time evaluation of the welding quality and the defects which can occur in laser welding.

  • PDF

Experimental Study of Nd:YAG Laser Cleaning System for Removing Acrylic Resin and Surface Characteristic (Nd:YAG 레이저를 이용한 금속유물에 코팅된 아크릴수지의 제거 및 표면 특성 연구)

  • Lee, Hye-Youn;Cho, Nam-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.4
    • /
    • pp.143-150
    • /
    • 2012
  • Laser cleaning have been found to be a useful cleaning tool to remove contaminants without inducing damage to the substrate and making secondary pollutant. In this study, the effect of Nd:YAG laser cleaning system, emitting at 1064 nm and 532 nm, on acrylic resin applied onto copper coupons and pieces of bronze was investigated. The samples after laser cleaning tests were examined using microscopy, FT-IR, SEM-EDS. As a result, the acrylic resin could be removed from most of the samples at low laser energy density. Laser wavelength 532 nm was more effective than 1064 nm because of using lower laser energy density, which could reduce heat damage to substrates. Although the acrylic resin was easily removed, it revealed melted surfaces and removed bronze patina which must remain. The problems should be solved by future studies using different laser system or laser wavelengths.

Development of Interferometer for Performance Assessment of IR Optical System (적외선 광학계통 성능평가를 위한 간섭계 개발)

  • 홍경희;고재준;이성태;장세안;오명호
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.179-185
    • /
    • 1991
  • Twyman-Green interferometer is developed for assessment of IR optical system performance. Light source is $CO_2$ gas laser which has 10.6$\mu \textrm m$ wavelength. The light beam is expanded to 2.5 cm dia by Ge lens and splitted by ZnSe parallel plane plate. One of the beams is reflected by refernce mirror which is operated PZT. The fringe will be detected by a pyro-electric vidicon camera and displayed by a CRT monitor. Here, the IR firinge is recorded on the thermal paper. In visible region, the light source is He-Ne laser. The fringe is detected by a CCD camera and displayed by the CRT monitor. The intensity of the fringe is digitized by a image card and processed by a PC. The wavefront aberration function, PSF and OTF are calculated. The results are displayed in 3-D graphs on the monitor or printed out by a line printer.

  • PDF

Photophysical and Photochemical Property of ATX-S10

  • Ito, Toshiaki;Okazaki, Shigetoshi;Kageyama, Kazumi;Hirohata, Toru;Kohno, Eiji;Hirano, Toru
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.527-529
    • /
    • 2002
  • Photodynamic therapy (PDT) is a medical treatment using laser and photosensitizing drug taken up to destroy cancer cells. Singlet oxygen ($^1$0$_2$) generation is strongly related to this treatment. We have built a direct detection system monitoring feeble luminescence, in the near IR region, from $^1$0$_2$, We have comparatively studied the photophysical and photochemical properties in solution of a newly developed drug ATX-S10 and Photofrin already investigated clinically. We demonstrdted that ATX-S10 was capable of efficiently yielding $^1$0$_2$, which may lead to highly efficient PDT treatment. Successive laser excitation photobleached ATX -S10 readily in a dose-dependent manner. This result shows that ATX -S10 is useful in setting up suitable medical treatment conditions to minimize side effects.

  • PDF