• Title/Summary/Keyword: IR Window

Search Result 66, Processing Time 0.033 seconds

The Study on the Quantitative Dust Index Using Geostationary Satellite (정지기상위성 자료를 이용한 정량적 황사지수 개발 연구)

  • Kim, Mee-Ja;Kim, Yoonjae;Sohn, Eun-Ha;Kim, Kum-Lan;Ahn, Myung-Hwan
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.267-277
    • /
    • 2008
  • The occurrence and strength of the Asian Dust over the Korea Peninsular have been increased by the expansion of the desert area. For the continuous monitoring of the Asian Dust event, the geostationary satellites provide useful information by detecting the outbreak of the event as well as the long-range transportation of dust. The Infrared Optical Depth Index (IODI) derived from the MTSAT-1R data, indicating a quantitative index of the dust intensity, has been produced in real-time at Korea Meteorological Administration (KMA) since spring of 2007 for the forecast of Asian dust. The data processing algorithm for IODI consists of mainly two steps. The first step is to detect dust area by using brightness temperature difference between two thermal window channels which are influenced with different extinction coefficients by dust. Here we use dynamic threshold values based on the change of surface temperature. In the second step, the IODI is calculated using the ratio between current IR1 brightness temperature and the maximum brightness temperature of the last 10 days which we assume the clear sky. Validation with AOD retrieved from MODIS shows a good agreement over the ocean. Comparison of IODI with the ground based PM10 observation network in Korea shows distinct characteristics depending on the altitude of dust layer estimated from the Lidar data. In the case that the altitude of dust layer is relatively high, the intensity of IODI is larger than that of PM10. On the other hand, when the altitude of dust layer is lower, IODI seems to be relatively small comparing with PM10 measurement.

Developments of the Wide Wavelength Range Polarimeter of the Domeless Solar Telescope at the Hida Observatory

  • Anan, Tetsu;Ichimoto, Kiyoshi;Oi, Akihito;Ueno, Satoru;Kimura, Goichi;Nakatani, Yoshikazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • We are developing a new universal spectropolarimeter on the Domeless Solar Telescope (DST) at the Hida Observatory to realize precise spectropolarimetric observations in a wide range of wavelength in visible and near infrared. The system aims to open a new window of plasma diagnostics by using Zeeman effect, Hanle effect, Stark effect, impact polarization, and atomic polarization for measuring the external magnetic field, electric field, or an anisotropy in the excitation of the atoms. The polarimeter is a successor of formerly developed polarimeter on DST, which make possible to observe a polarization in a photospheric spectral line with polarimetric accuracy of 10-2 (Kiyohara et al. 2004). The new system consists of a 60cm aperture vacuum telescope, a high dispersion vacuum spectrograph, polarization modulator / analyzer composed of a rotating waveplate whose retardation is constant for a wide range of wavelength and Wallaston prism, and a fast and large format CCD camera or IR camera. Spectral images in both orthogonal polarizations are taken simultaneously with a frame rate of ~20Hz while the waveplate rotates continuously in a rate of 1rev./sec. Thus It takes 5 ~ 60 sec to observe polarization with accuracy of 10-3 in a wide wavelength range (400 - 1100nm). We also examined a polarimetric model of the telescope with accuracy of 10-3 to calibrate instrumental polarization on some wavelengths. In this talk, I will focus on the performance of the instrument.

  • PDF

Small Target Detection Using Bilateral Filter Based on Edge Component (에지 성분에 기초한 양방향 필터 (Bilateral Filter)를 이용한 소형 표적 검출)

  • Bae, Tae-Wuk;Kim, Byoung-Ik;Lee, Sung-Hak;Kim, Young-Choon;Ahn, Sang-Ho;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.9C
    • /
    • pp.863-870
    • /
    • 2009
  • Bilateral filter (BF) is a nonlinear filter for sharpness enhancement and noise removal. The BF performs the function by the two Gaussian filters, the domain filter and the range filter. To apply the BF to infrared (IR) small target detection, the standard deviation of the two Gaussian filters need to be changed adaptively between the background region and the target region. This paper presents a new BF with the adaptive standard deviation based on the analysis of the edge component of the local window, also having the variable filter size. This enables the BF to perform better and become more suitable in the field of small target detection Experimental results demonstrate that the proposed method is robust and efficient than the conventional methods.

Effects of Solvent Viscosity on Conformational Dynamics of Heme-pocket in Myoglobin and Hemoglobin

  • Kim, Seong-Heun;Lim, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1825-1831
    • /
    • 2006
  • The influence of solvent viscosity on conformational dynamics of the heme-pocket, a small vacant site near the binding site of myoglobin (Mb) and hemoglobin (Hb), and playing a functionally important role by serving as a station in ligand binding and escape, was studied by probing time-resolved vibrational spectra of CO photodissociated from MbCO and HbCO in $D_2O$, 75 wt% glycerol/$D_2O$, and trehalose at 283 K. Two absorption bands ($B_1$ and $B_2$) of the sample in viscous solvents, arising from CO in the heme pocket, are very similar to those in $D_2O$. Two bands in Mb and Hb under all three solvents exhibit very similar nonexponential spectral evolution ($B_1$ band; blue shifting and broadening, $B_2$ band; narrowing with a negligible shifting), suggesting that in the present experimental time window of 100 ps, the extents of the spectral shift and narrowing is much influenced neither by the viscosity of solvent nor by the quaternary contact of Hb. Spectral evolution can be described by a biexponential function with a fast universal time constant of 0.52 ps and a slow time constant ranging from 13 to 32 ps. For both proteins in all three solvents majority of spectral evolution occurs with the fast universal time constant. The magnitude of the slow rate in the spectral shift of B1 band decreases with increasing solvent viscosity, indicating that it is influenced by global conformational change which is retarded in viscous solvent, thereby serve as a reporter of global conformational change of heme proteins after deligation.

Improvement of Cloud-data Filtering Method Using Spectrum of AERI (AERI 스펙트럼 분석을 통한 구름에 영향을 받은 스펙트럼 자료 제거 방법 개선)

  • Cho, Joon-Sik;Goo, Tae-Young;Shin, Jinho
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.137-148
    • /
    • 2015
  • The National Institute of Meteorological Research (NIMR) has operated the Fourier Transform InfraRed (FTIR) spectrometer which is the Atmospheric Emitted Radiance Interferometer (AERI) in Anmyeon island, Korea since June 2010. The ground-based AERI with similar hyper-spectral infrared sensor to satellite could be an alternative way to validate satellite-based remote sensing. In this regard, the NIMR has focused on the improvement of retrieval quality from the AERI, particularly cloud-data filtering method. The AERI spectrum which is measured on a typical clear day is selected reference spectrum and we used region of atmospheric window. We performed test of threshold in order to select valid threshold. We retrieved methane using new method which is used reference spectrum, and the other method which is used KLAPS cloud cover information, each retrieved methane was compared with that of ground-based in-situ measurements. The quality of AERI methane retrievals of new method was significantly more improved than method of used KLAPS. In addition, the comparison of vertical total column of methane from AERI and GOSAT shows good result.

Wide Bandgap 박막 태양전지 제작을 위한 P-type a-$SiO_x$:H layer 최적화에 관한 연구

  • Yun, Gi-Chan;Kim, Yeong-Guk;Park, Seung-Man;Park, Jin-Ju;Lee, Seon-Hwa;An, Si-Hyeon;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.153-153
    • /
    • 2010
  • p-i-n 형 비정질 실리콘 박막 태양전지에서 p층은 창물질(window material)로서 전기 전도도가 크고, 빛 흡수가 적어야한다. p층의 두께가 얇으면 p층 전체가 depletion layer가 되고 충분한 diffusion potential을 얻을 수 없어 open-circuit voltage ($V_{oc}$)가 작아진다. 반대로 p층 두께가 두꺼워지면 빛 흡수가 증가하고, 표면 재결합이 문제가 되어 변환효율이 감소한다. 밴드갭이 큰 물질로 창층을 제작하게 되면 보다 짧은 파장의 입사광이 직접 i층을 비추므로 Short-circuit current ($I_{sc}$) 와 fill factor를 증가시킬 수 있다. 하여 본 연구에서는 기존의 창층으로 사용되는 Boron을 doping한 p-type a-Si:H 대신에 $N_2O$를 첨가한 p-type a-$SiO_x$:H의 $N_2O$ flow rate에 따른 밴드갭의 변화에 관한 연구를 수행하였다. p-type a-$SiO_x$:H Layer는 $SiH_4$, $H_2$, $N_2O$, $B_2H_6$ 가스를 혼합하여 증착하게 되는데 $SiH_4$, 가스와 $H_2$ 가스의 혼합비는 1:20, $B_2H_6$ 농도는 0.5%로 고정 하였으며 $N_2O$의 flow rate을 가변하며 증착하였다. $N_2O$의 가변조건은 5에서 50sccm으로 가변하여 증착하며 일반적으로 사용되는 RF-PECVD (13.56MHz)를 이용하였고 증착 온도는 175도, 전극간의 거리는 40mm, 파워와 압력은 30W, 700mTorr로 고정하여 진행하였다. 전기적 특성을 알아보기 위해 eagle 2000 Glass를 사용하였고 구조적 특성은 p-type wafer를 사용하여 각각 대략 200nm의 두께로 증착하였다. 증착 두께는 Ellipsometry를 이용하였으며 전기 전도도는 Agilent사의 4156c를 구조적특성은 FT-IR을 사용하여 측정하였다. Conductivity(${\sigma}_d$)는 $N_2O$가 증가함에 따라 $8.73\;{\times}\;10^{-6}$에서 $5.06\;{\times}\;10^{-7}$으로 감소하였고 optical bandgap ($E_{opt}$)은 1.71eV에서 2.0eV로 증가함을 알 수 있었다. 또한 reflective index(n)의 경우는 4.32에서 3.52로 감소함을 나타내었다. 기존의 p-type a-Si:H에 비해 상당한 $E_{opt}$을 가지므로 빛 흡수에 의한 손실을 줄임으로서 $V_oc$를 향상 시킬 수 있으며 동시에 짧은 파장에서의 입사광이 직접 i층을 비추므로 $I_{sc}$와 FF를 향상 시킬 수 있으리라 예상된다. 다소 낮은 전도도만 개선한다면 고효율의 박막 태양전지를 제작 할 수 있을 것으로 기대된다.

  • PDF