• 제목/요약/키워드: IR Sensor

검색결과 431건 처리시간 0.042초

보상용 적외선 센서를 사용한 비분산 적외선 이산화탄소 센서의 온도특성 (Temperature Dependency of Non-dispersive Infrared Carbon Dioxide Gas Sensor by using Infrared Sensor for Compensation)

  • 이승환
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.124-130
    • /
    • 2016
  • NDIR $CO_2$ gas sensor was built with ASIC implemented thermopile sensor which included temperature sensor and unique elliptical waveguide structures in this paper. The temperature dependency of dual infrared sensor module ($CO_2$ and reference IR sensors) has been characterized and its output voltage characteristics according to the temperature and gas concentration were proposed for the first time. NDIR $CO_2$ gas and reference IR sensors showed linear output voltages according to the variation of ambient temperatures from 243 K to 333 K and their slopes were 14.2 mV/K and 8.8 mV/K, respectively. The output voltages of temperature sensor also presented a linear dependency according to the ambient temperature and could be described with V(T)=-3.191+0.0148T(V). The output voltage ratio between $CO_2$ and reference IR sensors revealed irrelevant to the changes of ambient temperatures and gave a constant value around 1.6255 with standard deviation 0.008 at 0 ppm. The output voltage of $CO_2$ gas sensor at zero ppm $CO_2$ gas consisted of two components; one is caused by the HPB (half pass-band) of IR filter and the other is attributed to the part of $CO_2$ absorption wavelength. The characteristics of output voltages of $CO_2$ gas sensor could be accurately modeled with three parameters which are dependent upon the ambient temperatures and represented small average error less than 1.5% with 5% standard deviation.

CCD/IR 영상에서의 다중 센서 다중 표적 추적 (Tracking of Multi-targets in CCD/IR Multi-sensor system for ITS application)

  • 이일광;고한석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.359-362
    • /
    • 2001
  • 본 논문에서는 광학센서와 적외선 센서를 사용하는 Multi-sensor 시스템에서 영상 정보를 통한 물체의 추적 및 인식에 필요한 영상을 분리하는데 필요한 전처리와 object 기반의 추적 방법을 제안하였다. 일반적인 추적 알고리즘의 목표는 consistency를 유지하는데 있다. 그러나 인식에 필요한 영상을 분리하기 위해서는 물체의 범위를 정확히 판단 할 수 있는 능력이 중요하다. 이를 위해 CCD와 IR영상에 동시에 적용 가능한 전처리 기법과 object 기반의 two-step 추적 알고리즘을 통해 consistency외에도, 물체의 범위를 estimation하여 인식에 필요한 범위를 분리해 낸다. 본 논문에서는 ITS 의 ETCS application을 위해 이종 센서인 CCD와 IR의 야간 차량 영상정보를 이용하여 알고리즘을 test 하였다.

  • PDF

영상센서의 비균일 응답특성 보정을 위한 흑체 설계 및 성능검증과 보정오차 분석 (Black Body Design and Verification for Non-Uniformity Correction of Imaging Sensor and Uncertainty Analysis)

  • 신소민
    • 한국항공우주학회지
    • /
    • 제41권3호
    • /
    • pp.240-245
    • /
    • 2013
  • 영상센서 중 적외선 센서는 시간경과 및 작동/비작동 반복에 따라 적외선 광원에 대한 응답특성이 조금씩 변화하며, 그 결과 영상품질이 저하된다. 그래서 인공위성에 탑재되는 적외선 센서의 경우 정상적인 임무수행을 위해 교정용 흑체로 주기적인 비균일 응답특성 보정을 실시할 수 있도록 해야 한다. 본 논문에서는 비균일 응답특성 보정을 위해, 적외선 센서의 파장대역 $3.3{\sim}5.2{\mu}m$에서 흑체 방사율이 0.995이상 평균온도차 $1^{\circ}C$ 이하가 되도록 V-그루브(groove) 타입의 흑체를 설계하였다. 성능검증을 위해 흑체의 방사율과 표면온도를 측정하여 검증하였으며, 그 결과로부터 비균일 응답특성 보정오차를 산출하였다.

IR-UWB 레이더 센서 기반 수면 효율 측정 알고리즘 (Sleep Efficiency Measurement Algorithm Using an IR-UWB Radar Sensor)

  • 최정우;이유나;조석현;임영효;조성호
    • 한국통신학회논문지
    • /
    • 제42권1호
    • /
    • pp.214-217
    • /
    • 2017
  • 본 논문에서는 원거리에서의 IR-UWB 레이더 센서기반 수면 효율 측정 알고리즘을 제안한다. IR-UWB 레이더로 수면 중 측정 가능한 호흡수, 심박수, 움직임 등의 생체 지표 중 움직임과 수면 효율과의 관련성을 분석하고, 움직임을 기반으로 한 수면 효율 측정 알고리즘을 제안한다. 이에 대한 타당성 및 성능검증을 위해 실제 병원에서의 수면다원검사 환자 3명에 대하여 본 알고리즘을 적용한 결과 평균 3.9% 이내의 절대오차를 갖는 검출성능을 얻었다.

MEMS-IR SENSOR용 식각-접합-박막증착 기반공정 (Etching-Bonding-Thin film deposition Process for MEMS-IR SENSOR Application)

  • 박윤권;주병권;박흥우;박정호;염상섭;서상희;오명환;김철주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2501-2503
    • /
    • 1998
  • In this paper, the silicon-nitride membrane structure for IR sensor was fabricated through the etching and the direct bonding. The PTO layer as a IR detection layer was deposited on the membrane and its characteristics were measured. The attack of PTO layer during the etching of silicon wafer as well as the thermal isolation of the IR detection layer can be solved through the method of bonding/etching of silicon wafer. Because the PTO layer of c-axial orientation raised thermal polarization without polling, the more integration capability can be achieved. The surface roughness of the membrane was measured by AFM, the micro voids and the non-contacted area were inspected by IR detector, and the bonding interface was observed by SEM. The polarization characteristics and the dielectric characteristics of the PTO layer were measured, too.

  • PDF

IR 및 UV센서를 이용한 아크 용접 품질 모니터링에 관한 연구 (A Study on On-line ARC Welding Monitoring using IR and UV sensor)

  • 윤충섭
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.314-316
    • /
    • 2005
  • 이 논문에서는 아크 용접시 발생하는 IR신호와 UV호의 상호 관계를 알아보려고 레이저 용접진단에 사용되는 IR-UV 센서 모니터링 시스템을 적용하였다. 그 결과 IR신호 크기는 용접폭에 관련이 있고, 펄스 형태의 UV신호는 IR신호 증가율이 임계값을 넘으면 나타나는 것을 알 수 있다.

  • PDF

항공용 EO/IR 센서의 EO GRD 분해능 실험실 측정 연구 (A Study of Laboratory Measurement of EO GRD Resolution for Airborne EO/IR Sensor)

  • 허준;김창우;김성수;김병완
    • 한국군사과학기술학회지
    • /
    • 제17권6호
    • /
    • pp.793-799
    • /
    • 2014
  • EO GRD(Ground Resolved Distance) resolution of airborne EO/IR(Electro-Optical/Infrared) sensor is a critical factor in test and evaluation for EO sensor performance. We propose the laboratory measurement set-up for EO GRD by constructing optical collimator which includes integrated sphere, blackbody, equivalent 3-bar target and 6 DOF motion simulator. GRD is measured in the photographic imagery of bar targets by 3 different distances for 3 EO/IR sensors and the measured results were analyzed statistically. We found that at least 7 sheets of imagery are needed in order to obtain meaningful EO GRD. The result of statistical analysis shows that the distribution of the measured GRD is nearly symmetric about the average GRD, and the better imagery ratio above the average GRD is about 40~70%. Also from the best GRD analysis, it is estimated that the design goal for EO GRD should be 30% superior to the required GRD.

IR 센서와 영상정보를 이용한 다 개체 로봇의 장애물 회피 방법 (Obstacle Avoidance Method for Multi-Agent Robots Using IR Sensor and Image Information)

  • 전병승;이도영;최인환;모영학;박정민;임묘택
    • 제어로봇시스템학회논문지
    • /
    • 제18권12호
    • /
    • pp.1122-1131
    • /
    • 2012
  • This paper presents obstacle avoidance method for scout robot or industrial robot in unknown environment by using IR sensor and vision system. In the proposed method, robots share the information where the obstacles are located in real-time, thus the robots can choose the best path for obstacle avoidance. Using IR sensor and vision system, multiple robots efficiently evade the obstacles by the proposed cooperation method. No landmark is used at wall or floor in experiment environment. The obstacles don't have specific color or shape. To get the information of the obstacle, vision system extracts the obstacle coordinate by using an image labeling method. The information obtained by IR sensor is about the obstacle range and the locomotion direction to decide the optimal path for avoiding obstacle. The experiment was conducted in $7m{\times}7m$ indoor environment with two-wheeled mobile robots. It is shown that multiple robots efficiently move along the optimal path in cooperation with each other in the space where obstacles are located.

IR센서 기반 보행보조기를 이용한 보행 시 경사상태에 따른 보행의지 파악에 관한 연구 (A Study on Walking Intention Detection of Gait Slope and Velocity of the Rollator Based on IR Sensor)

  • 이현종;강승록;유창호;권대규
    • 재활복지공학회논문지
    • /
    • 제8권4호
    • /
    • pp.259-265
    • /
    • 2014
  • 본 논문은 보행의지를 파악하기 위해 IR 센서 기반 보행보조기를 이용하여 보행 시 슬관절 전방변위 측정과 하지의 근육활성도를 고찰하였다. 슬관절 전방변위 측정을 위해 보행보조기에 IR센서를 장착하였고, 근전도 (Bagnoli-8ch, Delsys Inc, USA)장비를 이용하여 대퇴직근, 대퇴이두근, 전경골근, 비복근을 측정 하였다. 실험에 참가한 피험자들은 성인 8명(나이 $23.7{\pm}0.5years$, 신장 $175.4{\pm}2.3cm$, 체중 $70.6{\pm}5.6kg$)이며 매주 30분씩 총 3주간 진행되었다. 보행 시 경사조건과 보행 속도의 증가에 따라서 슬관절 전방변위가 변화되는 결과를 확인할 수 있었다. 또한 근육활성도 결과, 전방경사 시 대퇴부 근육의 활성도가 증가하였고 후방경사 시 하퇴부 근육이 많이 활성화 되어 IR센서 결과와 유사한 경향을 확인할 수 있었다.

  • PDF

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer

  • Choi, Ju Chan;Lee, June Kyoo;Kong, Seong Ho
    • 센서학회지
    • /
    • 제21권6호
    • /
    • pp.402-407
    • /
    • 2012
  • We report a Fabry-Perot interferometer (FPI)-based multi-channel micro-spectrometer used for multi-gas measurement in the spectral range of $3-5{\mu}m$ and its gas sensing performance. The fabricated infrared (IR) spectrometer consists of two parts: an FPI on the top side for selective IR filtering and a $V_2O_5$-based IR detector array on the bottom side for the detection of the filtered IR. Experimental results show that the FPI-based multi-channel gas sensor has reliability and selectivity for simultaneously detecting environmentally harmful gases such as $CH_4$, $CO_2$, $N_2O$ and CO in the spectral range of $3-5{\mu}m$. The fabricated FPI-based multi-channel gas sensor also demonstrated that a reliable and selective detection of gas concentrations ranging from 0 to 500 ppm is feasible. In addition, the electrical characteristics demonstrate a superior response performance in regards to the selectivity in the multi-target gases.