• Title/Summary/Keyword: IPS

Search Result 678, Processing Time 0.036 seconds

Factors associated with pulmonary toxicity after myeloablative conditioning using fractionated total body irradiation

  • Byun, Hwa Kyung;Yoon, Hong In;Cho, Jaeho;Kim, Hyun Ju;Min, Yoo Hong;Lyu, Chuhl Joo;Cheong, June-Won;Kim, Jin Seok;Kim, Hyo Sun;Kim, Soo-Jeong;Yang, Andrew Jihoon;Lee, Byung Min;Lee, Won Hee;Lee, Joongyo;Ahn, Ki Jung;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.257-267
    • /
    • 2017
  • Purpose: Pulmonary toxicities, including infectious pneumonia (IP) and idiopathic pneumonia syndrome (IPS), are serious side effects of total body irradiation (TBI) used for myeloablative conditioning. This study aimed to evaluate clinical factors associated with IP and IPS following TBI. Materials and Methods: Fifty-eight patients with hematologic malignancies who underwent TBI before allogeneic hematopoietic stem cell transplantation between 2005 and 2014 were reviewed. Most patients (91%) received 12 Gy in 1.5 Gy fractions twice a day. Pulmonary toxicities were diagnosed based on either radiographic evidence or reduced pulmonary function, and were subdivided into IP and IPS based on the presence or absence of concurrent infection. Results: Pulmonary toxicities developed in 36 patients (62%); 16 (28%) had IP and 20 (34%) had IPS. IP was significantly associated with increased treatment-related mortality (p = 0.028) and decreased survival (p = 0.039). Multivariate analysis revealed that the risk of developing IPS was significantly higher in patients who received stem cells from a matched unrelated donor than from a matched sibling donor (p = 0.021; hazard ratio [HR] = 12.67; 95% confidence interval [CI], 1.46-110.30). Combining other conditioning agents with cyclophosphamide produced a higher tendency to develop IP (p = 0.064; HR = 6.19; 95% CI, 0.90-42.56). Conclusion: IP and IPS involve different risk factors and distinct pathogeneses that should be considered when planning treatments before and after TBI.

Dynamic Bandwidth Allocation Algorithm with Two-Phase Cycle for Ethernet PON (EPON에서의 Two-Phase Cycle 동적 대역 할당 알고리즘)

  • Yoon, Won-Jin;Lee, Hye-Kyung;Chung, Min-Young;Lee, Tae-Jin;Choo, Hyun-Seung
    • The KIPS Transactions:PartC
    • /
    • v.14C no.4
    • /
    • pp.349-358
    • /
    • 2007
  • Ethernet Passive Optical Network(EPON), which is one of PON technologies for realizing FTTx(Fiber-To-The-Curb/Home/Office), can cost-effectively construct optical access networks. In addition, EPON can provide high transmission rate up to 10Gbps and it is compatible with existing customer devices equipped with Ethernet card. To effectively control frame transmission from ONUs to OLT EPON can use Multi-Point Control Protocol(MPCP) with additional control functions in addition to Media Access Control(MAC) protocol function. For EPON, many researches on intra- and inter-ONU scheduling algorithms have been performed. Among the inter-ONU scheduling algorithms, IPS(Interleaved Polling with Stop) based on polling scheme is efficient because OLT assigns available time portion to each ONU given the request information from all ONUs. Since the IPS needs an idle time period on uplink between two consecutive frame transmission periods, it wastes time without frame transmissions. In this paper, we propose a dynamic bandwidth allocation algorithm to increase the channel utilization on uplink and evaluate its performance using simulations. The simulation results show that the proposed Two-phase Cycle Danamic Bandwidth Allocation(TCDBA) algorithm improves the throughput about 15%, compared with the IPS and Fast Gate Dynamic Bandwidth Allocation(FGDBA). Also, the average transmission time of the proposed algorithm is lower than those of other schemes.

Shear Bond Strength of Resin Cements on the IPS e.max Press (IPS e.max Press에 대한 수종 레진 시멘트의 전단결합강도에 관한 연구)

  • Lee, Kyung-Eun;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.311-322
    • /
    • 2010
  • The purpose of this study was to evaluate the bond strengths between IPS e.max Press and four different types of resin cements that often used for esthetic restoration. Disc shaped IPS e.max Press blocks(N=40, diameter: 12mm, thickness: 3mm) were fabricated according to the manufacture's instruction and cleaned with ultrasonic cleaner. They were embedded into an autopolymerizing acrylic resin. Fourty cylinder shaped resin block(Filtek Z350, diameter: 4.5mm, thickness: 3mm) were fabricated using a plastic tube. Each specimens were randomly divided into 4 experimental group and bonded each other using 4 different resin cements(Variolink II(light-cure), Variolink II(dual-cure), Calibra, Super-Bond C&B) according to the manufactures' recommendations. All the specimens were stored in normal saline at $37^{\circ}C$ for 24 hours before test. Universal testing machine at a crosshead speed of 1mm/min was used to evaluate the shear bond strength. The data were statistically analyzed using one-way ANOVA(P<.01). Multiple comparison was done by the Tukey HSD test. The shear bond strength of Super-Bond C&B to e.max was significantly lower than those of Calibra, Variolink II(light-cure), Variolink II(dual-cure) (P<.01). The shear bond strength of Calibra, Variolink II(light-cure), Variolink II(dual-cure) to e.max were not significantly different. The shear bond strengths of light-cure/dual-cure cement were higher than that of self-cure cement.

A study on the arrangement of integrated power system for warship (함정의 통합 전력시스템 구성에 관한 연구)

  • Baek, Hyun-Min;Jung, Kyun-Sik;Lee, Myung-Ho;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1070-1074
    • /
    • 2014
  • According to IEEE 1662(2009), IPS is a power system where all prime movers produce electrical power that is shared among propulsion, mission, and ship service loads. Discriminating attributes of integrated power systems are flexibility of movers' arrangements, mechanical decoupling between prime movers and propulsors, an increased level of energy conversion and transmission redundancy, and flexibility of redistributing available electrical power for future electronic weapons. IPS could have various steps of power that can be produced at optimal load of movers. In this study, an evaluation method for optimal arrangement of movers was investigated when an IPS warship is projected. The two factors are utilized for the quantitative analysis which are the weight of system as the fighting power and the fuel consumption per year as the economic feasibility. And also the ways for arrangement of system were studied according to existence of small diesel generator. The evaluation method that decides the optimization level is based on the DEA(Data Envelopment Analysis)

A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE (주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구)

  • Dong, Jin-Keun;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

XSNP: An Extended SaC Network Protocol for High Performance SoC Bus Architecture (XSNP: 고성능 SoC 버스를 위한 확장된 SoC 네트워크 프로토콜)

  • Lee Chan-Ho;Lee Sang-Hun;Kim Eung-Sup;Lee Hyuk-Jae
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.8
    • /
    • pp.554-561
    • /
    • 2006
  • In recent years, as SoC design research is actively conducted, a large number of IPs are included in a system. Various bus protocols and bus architectures are designed to increase IP reusability. Among them, the AMBA AHB became a de facto standard although it is somewhat inadequate for a large scale SoC. We proposed SNP and SNA, high performance on-chip-bus protocol and architecture, respectively, to solve the problem of the conventional shared buses. However, it seems to be imperative that the new on-chip-bus system support AMBA-compatible IPs for a while since there are a lot of IPs with AMBA interface. In this paper, we propose an extended SNP specification and a corresponding SNA component to support ABMA-compatible IPs used in SNA - based system. We extend the phase of the SNP by 1 bit to add new 8 phases to support communication based on AMBA protocol without penalty of elongated cycle latency. The ARB-to -XSNP converter translates the protocol between AHB and SNP to attach AMBA -compatible IPs to SNA based system. We show that AMBA IPs can communicate through SNP without any degradation of performance using the extended SNP and AHB - to- XSNP converter.

An Analog Front-End Circuit for ISO/IEC 14443-Compatible RFID Interrogators

  • Min, Kyung-Won;Chai, Suk-Byung;Kim, Shi-Ho
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.560-564
    • /
    • 2004
  • An analog front-end circuit for ISO/IEC 14443-compatible radio frequency identification (RFID) interrogators was designed and fabricated by using a $0.25{\mu}m$ double-poly CMOS process. The fabricated chip was operated using a 3.3 Volt single-voltage supply. The results of this work could be provided as reusable IPs in the form of hard or firm IPs for designing single-chip ISO/IEC 14443-compatible RFID interrogators.

  • PDF

Integrated Control Center on the drawing board for the Northeast Asia Region Interconnected Power System (동북아 연합급전소 구상)

  • Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.20-23
    • /
    • 2005
  • This paper introduces the latest discussions on the Integrated Dispatch Center (IDC, or Integrated Control Center: ICC) for the Northeast Asia Region Interconnected Power System (NEAR-IPS). The IDC is for the safety and economical operation of the NEAR-IPS. The status and plans of the EPSs and the control systems (or dispatch centers) to be interconnected shall be reviewed and the consideration on the IDC to be built in the future shall be discussed.

  • PDF

Invited Paper, A novel LCD using S-IPS technology for the application of public display

  • Kim, Kyeong-Jin;Park, Su-Jung;Choi, Sang-Ho;Kim, Jin-Ho;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1649-1651
    • /
    • 2008
  • A novel configured S-IPS LCD has been developed introducing a new compensation film with an anti-reflective layer. This new technology provides wide viewing characteristics as well as excellent visibility under bright indoor lighting or natural lighting.

  • PDF

Development of the high speed response and high clearing temperature LC mixtures for TV Application of IPS-LCD

  • You, S.K.;Kim, Y.B.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.604-607
    • /
    • 2003
  • Three ring type LC compounds substituted with isothiocyanato group and fluoro atoms in phenyl ring were synthesized, and blended with KL-series LC mixtures for TV application of TN and IPS-mode. Clearing temperature of new LC mixtures are shown $10{\sim}35{\square}$ higher than commercial mixtures. And response time was also improved $10{\sim}20%$ faster than conventional LC mixtures.

  • PDF