• Title/Summary/Keyword: ION

Search Result 16,622, Processing Time 0.04 seconds

Effect of $NH_4^{+}$ Ion on the Transpot System of Amino Acids (아미노산의 능동 수송계에 미치는 $NH_4^{+}$ 이온의 영향)

  • 조봉희
    • Korean Journal of Plant Tissue Culture
    • /
    • v.26 no.2
    • /
    • pp.99-102
    • /
    • 1999
  • Glucose - induced arginine transport system was induced by a exogenous application of NH$_4$^+ ion. The uptake rate of arginine (Arg) depended on the external NH$_4$^+ ion concentration. The uptake rate was inhibited by the presence of NH$_4$^+ ion within 1 min, whereas it increased maximally after 30 min. Glucose and NH$_4$^+ ion induced the same arginine transport system. Km value of Arg transport systems was 2 $\mu$M, and V_(max) was 60 $\mu$mol^(-1) . h . g fresh weight^(-1) for NH$_4$^+ ion and 174 $\mu$mol^(-1) . h . g fresh weight^(-1) for glucose induced transport system. But, the transport system of Glu for glucose and NH$_4$^(-1) ion induced had different Km values. Km value of Glu was 285 $\mu$M for glucose - and 58 $\mu$M for NH$_4$^+ ion induced transport system. Thus, NH$_4$^+ ions play a important role as inducer for the glutamine transport system. NH$_4$^+ ion induced glutamine system was inhibited over 90% by cycloheximide. We concluded that a new carrier protein for glutamine was induced by NH$_4$^+ ion.

  • PDF

Electro-optical Characteristics of Twisted Nematic(TN)-LCD using New Ion Beam Equipment (새로운 이온빔장치를 사용한 Twisted Nematic-LCD의 전기광학특성)

  • Kim Sang-Hoon;Hwang Jeoung-Yeon;Jang Mi-Hye;Kim Gwi-Yeol;Seo Dae-Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.547-551
    • /
    • 2006
  • We studied liquid crystal (LC) alignment with ion beam (IB) on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the polyimide surface using obliquely ion beam (IB) exposure with new IB type equipment. A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-LCD on polyimide surface. Also, the EO characteristics of the ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using new type IB equipment is same or more superior than ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using Kaufman-type Ar ion gun.

EO performance of IPS cell on the inorganic films surface using DuoPIGatron ion source (유기박막표면에 DuoPIGatron 이온소스를 이용한 IPS 셀의 전기광학 특성)

  • Kim, Byoung-Yong;Hwang, Jeoung-Yeon;Kim, Sang-Hun;Han, Jung-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.89-90
    • /
    • 2006
  • Electro-optical (EO) characteristics of in-plane switching (IPS) cell on the polyimide surface using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned IPS-cell on poly imide surface ; the stable VT curve in the ion-beam-aligned IPS cell on a poly imide (PI) surface with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned IPS cell on a polyimide (PI) surface with ion beam exposure using new type IB equipment was obtained.

  • PDF

EO performance of TN cell on the inorganic films surface using DuoPIGatron ion source on NDLC thin film (무기박막표면에 DuoPIGatron 이온소스를 이용한 TN-LCD 셀의 전기광학 특성)

  • Kim, Byoung-Yong;Hwang, Jeoung-Yeon;Kim, Sang-Hun;Han, Jung-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.432-433
    • /
    • 2006
  • Electro-optical (EO) characteristics of twisted nematic (TN) - liquid crystal display (LCD) on the NDLC thin film using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the NDLC thin film was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-cell on polyimide surface ; the stable VT curve in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained.

  • PDF

Studies on the Adsarption Characteristics of Fluoride Ion-Containing Wastewater by Employing Waste Oyster Shell as an Adsorbent (폐굴껍질을 흡착제로 한 불소폐수 처리특성에 관한 연구)

  • Lee, Jin-Suk;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.222-227
    • /
    • 2007
  • The adsorption features of fluoride ion on the oyster shell have been investigated for the purpose of the employment of waste oyster shell as an adsorbent for the treatment of fluoride ion-containing wastewater. The major component of oyster shell was examined to be Ca with minor components of Na, Si, Mg, Al, and Fe. As the initial concentration of fluoride ion was raised, its absorbed amount was enhanced at equilibrium, however, the adsorption ratio of fluoride ion compared with its initial concentration was shown to be decreased. Also, adsorption of fluoride ion onto the oyster shell resulted in the formation of $CaF_2$ in the morphological structure of adsorbent. Kinetic analysis showed that the adsorption reaction of fluoride ion generally followed a second order reaction with decreasing rate constant with the initial concentration of adsorbate. Freundlich model agreed well with the adsorption behavior of fluoride ion at equilibrium and the adsorption reaction of fluoride ion was examined to be endothermic. Several thermodynamic parameters for the adsorption reaction were calculated based on thermodynamic equations and the activation energy for the adsorption of fluoride ion onto oyster shell was estimated to be ca. 13.589 kJ/mole.

Age-dependent expression of ion channel genes in rat

  • Sung-Cherl Jung;Tong Zhou;Eun-A Ko
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.27 no.1
    • /
    • pp.85-94
    • /
    • 2023
  • Ion channels regulate a large number of cellular functions and their functional role in many diseases makes them potential therapeutic targets. Given their diverse distribution across multiple organs, the roles of ion channels, particularly in age-associated transcriptomic changes in specific organs, are yet to be fully revealed. Using RNA-seq data, we investigated the rat transcriptomic profiles of ion channel genes across 11 organs/tissues and 4 developmental stages in both sexes of Fischer 344 rats and identify tissue-specific and age-dependent changes in ion channel gene expression. Organ-enriched ion channel genes were identified. In particular, the brain showed higher tissue-specificity of ion channel genes, including Gabrd, Gabra6, Gabrg2, Grin2a, and Grin2b. Notably, age-dependent changes in ion channel gene expression were prominently observed in the thymus, including in Aqp1, Clcn4, Hvcn1, Itpr1, Kcng2, Kcnj11, Kcnn3, and Trpm2. Our comprehensive study of ion channel gene expression will serve as a primary resource for biological studies of aging-related diseases caused by abnormal ion channel functions.

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

Development of Inductively Coupled Plasma Gas Ion Source for Focused Ion Beam (유도결합형 플라즈마 소스를 이용한 집속 이온빔용 가스 이온원 개발)

  • Lee, Seung-Hun;Kim, Do-Geun;Kang, Jae-Wook;Kim, Tae-Gon;Min, Byung-Kwon;Kim, Jong-Kuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.19-23
    • /
    • 2011
  • Recently, focused ion beam (FIB) applications have been investigated for the modification of VLSI circuit, the MEMS processing, and the localized ion doping, A multi aperture FIB system has been introduced as the demands of FIB applications for high speed and large area processing increase. A liquid metal ion source has problems, a large angular divergence and a metal contamination into a substrate. In this study, a gas ion source was introduced to replace a liquid metal ion source. The gas ion source generated inductively coupled plasma (ICP) in a quartz tube (diameter: 45 mm). Ar gas fed into the quartz was ionized by a 2 turned radio frequency antenna. The Ar ions were extracted by 2 extraction grids. The maximum extraction voltage was 10 kV. A numerical simulation was used to optimize the design of extraction grids and to predict an ion trajectory. As a result, the maximum ion current density was 38 $mA/cm^2$ and the spread of ion energy was 1.6 % for the extraction voltage.

DISCOLORATION AND CORROSION RESISTANCE OF TiN-COATED ORTHODONTIC APPLIANCES PRODUCED BY ION-PLATING METHOD (Ion-plating법에 의하여 TiN 피막처리된 교정용 장치물의 변색성 및 내식성)

  • Kim, Jin-Hee;Kwon, Oh-Won;Choi, Young-Yun
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.327-340
    • /
    • 1993
  • The purpose of this study was to estimate the possibility of practical application of TiN ion-plating method on orthodontic appliances. TiN was coated on the surface of orthodontic stainless steel roll band by means of ion-plating method, and colorimetric properties of its obtained TiN film were investigated by using color analyzer. Also its corrosion and discoloration properties were compared with those of non ion-plated stainless steel roll band by using immersion test, which was done in 1N HCl solution for 10 days. Both weight changes and surface corrosion appearances of specimens for each day were respectively investigated by using electronic weighing machine and SEM(Scanning Electron Microscope). The discoloration degress of TiN-coated specimens immersed in 1N HCl solution were investigated by using color analyzer and then judged by N.B.S.(National Bureau of Standard) Unit. The results of this study were summarized as follows. o TiN ion-plated films showed the hue of 5Y, the value of 7, and the chroma of 3 by Munsell notations. o The weight losses and surface changes of TiN ion-plated specimens immersed in 1N HCl solution were less than those of non ion-plated specimens. It was shown, therefore, that the corrosion resistance was significantly improved by TiN ion-plating. o The discoloration degrees of non ion-plated specimens were too significant to be examined by color analyzer, while those of TiN ion-plated specimens were slight when judged by N.B.S. Unit. It was also apparent, therefore, that the anti-discoloration property was significantly improved by TiN ion-plating.

  • PDF

The Additional Filter and Ion Chamber Sensor Combination for Reducing Patient Dose in Digital Chest X-ray Projection (디지털 흉부엑스선 검사에서 환자선량 감소를 위한 부가필터와 Ion chamber 센서 조합)

  • Lee, Jinsoo;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, we studied additional filter and Ion chamber combinations to reduce patient dose without decreasing image quality in digital chest x-ray projection. The experiment set 125 kVp, 320 mA, AEC mode. Ion chamber sensors was divided by 4 cases of combinations, then, we measured patient dose and calculated organ dose using PCXMC. Also, physical image assessment using MTF was performed. As a results, The surface entrance dose and organ dose were the lowest when selecting both left and right Ion chamber sensors under the same conditions of additional filter. In image quality assessment, The spatial frequency scored 2.494 lp/mm which was highest when selecting both right and left Ion-chambers and 0.1 mmCu filter. And to conclude, to select both right and left Ion chamber sensors and 0.1 mmCu filter will help for acquiring good quality image as well as reducing patient dose.