• Title/Summary/Keyword: INSPECTION

Search Result 10,149, Processing Time 0.037 seconds

Residual Characteristics and Monitoring of Cyenopyrafen and Cyflumetofen in Strawberries for Export (수출딸기 중 Cyenopyrafen과 Cyflumetofen의 잔류소실 특성평가 및 잔류농약 모니터링)

  • Kim, Yeong-Jin;Kim, Jong-Hwan;Kwon, Young-Sang;Song, Jong-Wook;Seo, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.279-287
    • /
    • 2017
  • BACKGROUND: Many farmers who cultivate the strawberries for export have used agricultural chemicals which MRL (Maximum Residue Limits) of main export target countries or simultaneous multi-residue analysis in Korea have not been established. Among them, the cyenopyrafen and cyflumetofen were selected and applied to this study to determine the PHI (pre-harvest interval) which is appropriate to the PLS (Positive List System) criterion (0.01 mg/kg) and to investigate the residual amounts in the samples. In addition, Fifty pesticides were monitored to check up whether it is suitable or not for main export target countries. METHODS AND RESULTS: Cyenopyrafen and cyflumetofen were spayed out to the strawberries. Samples for residual analyses were taken for maximum 60 days. After sampling, they were extracted by the QuEChERS method and analyzed using the LC-MS/MS. Cyenopyrafen and cyflumetofen were detected in a range of 0.0106~2.6517 mg/kg and of 0.0005~1.4480 mg/kg, respectively. From this results, they were found to be suitable for PLS concentration after 30 or 45 days after spray. In addition, they were detected in most samples that were selected at random. Their concentrations were higher than the PLS criterion in the maximum twenty samples. Twelve of pesticides unsuitable for main export target countries have been detected in the monitoring of simultaneous multi-residue analysis. The result indicates they are unsuitable for export since they excesses over PLS criterion. CONCLUSION: The monitoring result showed it is necessary to establish the pesticide standards of safe use suitable for the PLS criterion. In addition, it is considered continues management and inspection are needed to solve problems caused by unsuitable pesticides in export strawberries.

Monitoring of Benzoic Acid, Sorbic Acid, and Propionic Acid in Spices (향신료에서 유래되는 안식향산, 소브산, 프로피온산의 함유량 조사)

  • Yun, Sang Soon;Lee, Sang Jin;Lim, Do Yeon;Lim, Ho Soo;Lee, Gunyoung;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.381-388
    • /
    • 2017
  • In this study, we investigated the levels of natural preservatives of benzoic acid, sorbic acid, and propionic acid in spices. The quantitative analysis was performed using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for benzoic acid and sorbic acid and gas chromatography-mass spectrometry (GC-MS) for propionic acid. The sample was extracted with ethanol using sonication, then centrifuged and evaporated to dryness and redissolved to 1 mL with ethanol to use for the instrumental analysis. The analytical method was validated based on linearity, recovery, limit of detection (LOD), and limit of quantification (LOQ). This method was suitable to determine low amounts of naturally occurring preservatives (benzoic acid, sorbic acid, and propionic acid) in various spices. Benzoic acid, sorbic acid, and propionic acid were found in 165 samples, 88 samples, and 398 samples, respectively from the total of 493 samples. The concentration of benzoic acid, sorbic acid, and propionic acid were ranged at ND-391.99 mg/L, ND-57.70 mg/L, and ND-188.21 mg/L in spices, respectively. The highest mean levels of benzoic acid, sorbic acid, and propionic acid were found in cinnamon (167.15 mg/L), basil leaves (22.79 mg/L), and white pepper (51.48 mg/L), respectively. The results in this study provide ranges of concentration regarding naturally occurring benzoic acid, sorbic acid, and propionic acid in spices. Moreover, the results may use to the case of consumer complaint or trade friction due to the inspection services of standard criteria for the preservatives of spices.

Development and Validation of an Analytical Method for Determination of Fungicide Tridemorph in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 tridemorph의 시험법 개발 및 검증)

  • Pak, Won-Min;Do, Jung-Ah;Lim, Seung-Hee;Park, Shin-Min;Yoon, Ji-Hye;Lee, Dong-seouk;Chang, Moon-Ik
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.290-297
    • /
    • 2017
  • The purpose of this study was developed for the determination of tridemorph in agricultural commodities samples. Tridemorph residues in samples were extracted with acetonitrile, partitioned with saline water, and then purified using and aminopropyl ($NH_2$) SPE catridge. The purified samples were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~2.5 ng) into a blank extract with $r^2$ > 0.999. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. The average recovery ranged between 75.9% and 103.7% at different concentration levels (LOQ, 10 LOQ, 50 LOQ, n = 5) with relative standard deviations (RSDs) less than 9.0%. An interlaboratory study was conducted to validate the method by Korea Advanced Food Research Institute. The average recovery ranged between 87.0% and 109.2% at different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n = 5) with relative standard deviations (RSDs) less than 8.0%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003) and Food Safety Evaluation Department guidelines (2016). The results prove that the developed analytical methods is accurate, effective and sensitive for tridemorph determination.

Development and Validation of an Analytical Method for Determination of Fungicide Benzovindiflupyr in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 벤조빈디플루피르의 잔류시험법 개발 및 검증)

  • Lim, Seung-Hee;Do, Jung-Ah;Park, Shin-Min;Pak, Won-Min;Yoon, Ji Hye;Kim, Ji Young;Chang, Moon-Ik
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.298-305
    • /
    • 2017
  • Benzovindiflupyr is a new pyrazole carboxamide fungicide that inhibits succinate dehydrogenase of mitochondrial respiratory chain. This study was carried out to develop an analytical method for the determination of benzovindiflupyr residues in agricultural commodities using LC-MS/MS. The benzovindiflupyr residues in samples were extracted by using acetonitrile, partitioned with dichloromethane, and then purified with silica solid phase extraction (SPE) cartridge. Correlation coefficient ($r^2$) of benzovindiflupyr standard solution was 0.99 over the calibration ranges ($0.001{\sim}0.5{\mu}g/mL$). Recovery tests were conducted on 5 representative agricultural commodities (mandarin, green pepper, potato, soybean, and hulled rice) to validate the analytical method. The recoveries ranged from 79.3% to 110.0% and then relative standard deviation (RSD) was less than 9.1%. Also the limit of detection (LOD) and limit of quantification (LOQ) were 0.0005 and 0.005 mg/kg, respectively. The recoveries of interlaboratory validation ranged from 83.4% to 117.3% and the coefficient of variation (CV) was 9.0%. All results were followed with Codex guideline (CAC/GL 40) and Ministry of Food and Safety guideline (MFDS, 2016). The proposed new analytical method proved to be accurate, effective, and sensitive for benzovindiflupyr determination and would be used as an official analytical method.

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

Optimization for Underwater Welding of Marine Steel Plates (선박용 강판의 수중 용접 최적화에 관한 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 1984
  • Optimizing investigation of characteristics of underwater welding by a gravity type arc welding process was experimentally carried out by using six types of domestic coated welding electrodes for welding of domestic marine structural steel plates (KR Grade A-1, SWS41A, SWS41B,) in order to develop the underwater welding techniques in practical use. Main results obtained are summarized as follows: 1. The absorption speed of the coating of domestic coated lime titania type welding-electrode became constant at about 60 minutes in water and it was about 0.18%/min during initial 8 minutes of absorption time. 2. Thus, the immediate welding electrode could be used in underwater welding for such a short time in comparison with the joint strength of in-atmosphere-and on-water-welding by dry-, wet-or immediate-welding-electrode. 3. By bead appearance and X-ray inspection, ilmenite, limetitania and high titanium oxide types of electrodes were found better for underwater-welding of 10 mm KR Grade A-1 steel plates, while proper welding angle, current and electrode diameter were 6$0^{\circ}C$, above 160A and 4mm respectively under 28cm/min of welding speed. 4. The weld metal tensile strength or proof stress of underwater-welded-joints has a quadratic relationship with the heat input, and the optimal heat input zone is about 13 to 15KJ/cm for 10mm SWS41A steel plates, resulting from consideration upon both joint efficiency of above-100% and recovery of impact strength and strain. Meanwhile, the optimal heat input zone resulting from tension-tension fatigue limit above the base metal's of SWS41A plates is 16 to 19KJ/cm. Reliability of all the empirical equations reveals 95% confidence level. 6. The microstructure of the underwater welds of SES41A welded in such a zone has no weld defects such as hydrogen brittleness with supreme high hardness, since the HAZ-bond boundary area adjacent to both surface and base metal has only Hv400 max with the microstructure of fine martensite, bainite, pearlite and small amount of ferrite.

  • PDF

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

Field Assessment of Sanitation Management for School Foodservice Suppliers in the Seoul Area (서울지역 학교급식 식재료 납품업체 위생관리 실태 평가)

  • Lee, Kyung-Mi;Ryu, Kyung
    • Korean journal of food and cookery science
    • /
    • v.23 no.5
    • /
    • pp.650-663
    • /
    • 2007
  • The purpose of this study was to identify the sanitation management items of school foodservice suppliers that require improvement, by assessing their sanitation practices with food commodities. Our field assessment was performed using a total of 20 vendors supplying agricultural products, meat products, seafoods and processed products; all were located in the Seoul and Gyeonggi areas. The assessment tool for sanitation management was composed of 93 checklist items and was used to evaluate seven different categories; the facility and environment, management of the facility and equipment, food materials management, process control, water management, personal hygiene management, and laboratory instrument management. A score of two was given for "satisfactory", one for "fair", and zero for "unsatisfactory". The overall average supplier score was 1.7/2.0 (85.8%). The score of the seafood vendors was highest at 1.9 (95.4%), while the lowest score of 1.3 (65.7%) occurred with the processed product suppliers. Among the sanitation management categories, water management was scored at 2.0, while inspection management was lowest at 1.4. The subcategories indicating needed improvements for the processed product suppliers were raw materials, storage, transport and recall. For the agricultural product suppliers it was preparation management. furthermore, one item within the laboratory instrument management category was unsatisfactory for both the agricultural and processed product suppliers. In conclusion, these results can be used to develop sanitation management procedures for suppliers, as well as by administration agencies to evaluate and guide those suppliers.

Comparison of Response Systems and Education Courses against HNS Spill Incidents between Land and Sea in Korea (국내 HNS 사고 대응체계 및 교육과정에 관한 육상과 해상의 비교)

  • Kim, Kwang-Soo;Gang, Jin Hee;Lee, Moonjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2015
  • As the type of Hazardous and Noxious Substances(HNS) becomes various and the transport volume of HNS increases, HNS spill incidents occur frequently on land and the sea. In view of various damages to human lives and properties by HNS spills, it is necessary to educate and train professional personnel in preparation for and response to potential HNS spills. This study shows the current state of response systems and education courses against HNS spill incidents on land and the sea to compare those with each other between land and sea in Korea. Incident command system on land are basically similar to that at sea, but leading authority which is responsible for combating HNS spills at sea is changeable depending on the location of HNS spill, as it were, Korea Coast Guard(KCG) is responsible for urgent response to HNS spill at sea, while municipalities are responsible for the response to HNS drifted ashore. Education courses for HNS responders on land are established at National Fire Service Academy(NFSA), National Institute of Chemical Safety(NICS), etc., and are diverse. Education and training courses for HNS responder at sea are established at Korea Coast Guard Academy(KCGA) and Marine Environment Research & Training Institute(MERTI), and are comparatively simple. Education courses for dangerous cargo handlers who work in port where land is linked to the sea are established at Korea Maritime Dangerous Goods Inspection & Research Institute(KOMDI), Korea Port Training Institute(KPTI) and Korea Institute of Maritime and Fisheries Technology(KIMFT). Through the comparison of education courses for HNS responders between land and sea, some recommendations such as extension of education targets, division of an existing integrated HNS course into two courses composed of operational level and manager level with respective refresh course, on-line cyber course and joint inter-educational institute course in cooperation with other relevant institutes are proposed for the improvement in education courses of KCG and KOEM(Korea Marine Environment Management Corporation) to educate and train professionals for combating HNS spills at sea in Korea.

Prioritizing Noxious Liquid Substances (NLS) for Preparedness Against Potential Spill Incidents in Korean Coastal Waters (해상 유해액체물질(NLS) 유출사고대비 물질군 선정에 관한 연구)

  • Kim, Young-Ryun;Choi, Jeong-Yun;Son, Min-Ho;Oh, Sangwoo;Lee, Moonjin;Lee, Sangjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.846-853
    • /
    • 2016
  • This study prioritizes Noxious Liquid Substances (NLS) transported by sea via a risk-based database containing 596 chemicals to prepare against NLS incidents. There were 158 chemicals transported in Korean waters during 2014 and 2015, which were prioritized, and then chemicals were grouped into four categories (with rankings of 0-3) based on measures for preparedness against incident. In order to establish an effective preparedness system against NLS spill incidents on a national scale, a compiling process for NLS chemicals ranked 2~3 should be carried out and managed together with an initiative for NLS chemicals ranked 0-1. Also, it is advisable to manage NLS chemicals ranked 0-1 after considering the characteristics of NLS specifically transported through a given port since the types and characteristics of NLS chemicals relevant differ depending on the port. In addition, three designated regions are suggested: 1) the southern sector of the East Sea (Ulsan and Busan); 2) the central sector of the South Sea (Gwangyang and Yeosu); and 3) the northern sector of the West Sea (Pyeongtaek, Daesan and Incheon). These regions should be considered special management sectors, with strengthened surveillance and the equipment, materials and chemicals used for pollution response management schemes prepared in advance at NLS spill incident response facilities. In the near future, the risk database should be supplemented with specific information on chronic toxicity and updated on a regular basis. Furthermore, scientific ecotoxicological data for marine organisms should be collated and expanded in a systematic way. A system allowing for the identification Hazardous and Noxious Substances (HNS) should also be established, noting the relevant volumes transported in Korean waters as soon as possible to allow for better management of HNS spill incidents at sea.