• Title/Summary/Keyword: IMPACT

Search Result 36,702, Processing Time 0.062 seconds

Physicochemical Properties of Powdered Green Teas in Korea (국내 시판 가루녹차의 이화학적 품질특성)

  • Lee, Lan-Sook;Park, Jong-Dae;Cha, Hwan-Soo;Lee, You-Min;Park, Jae-Woong;Kim, Sang-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • This study was conducted to compare the physicochemical properties of powdered green teas produced in Korea and Japan including particle size, color, chlorophyll, caffeine and theanine. The average particle size of Korean powered green tea ($14.63-25.39\;{\mu}m$) was similar to that of Japanese powdered green tea ($15.46-21.02\;{\mu}m$). The surface color of shade-cultivated Haenam Green Tea (HN-1) had the highest negative 'a' value, which represents 'green' color. When the TCD (total color difference value) was measured in the samples, HN-1 was most similar to the premium powdered green tea of Japan (JA-1). Domestic shade-cultivated powdered green teas had 1.5-2 times greater chlorophyll content than powdered green teas produced from plants that were not cultivated in the shade. The presence of chlorophyll a resulted in a higher intensity of green color than the presence of chlorophyll b. A significant negative correlation was also observed between the color and the chlorophyll a, chlorophyll b and total chlorophyll contents. Specifically, chlorophyll a had the greatest impact on the green color of powdered green tea. The content of catechins, caffeine and theanine in Korean powdered green teas ranged from 14.679-20.128, 1.496-3.237 and 0.926-1.977 g/100 g, respectively. The caffeine and theanine contents were high in shade-cultivated powdered green teas. Based on the above results, domestic powdered green teas cultivated under shaded conditions had a quality similar to that of medium-quality green teas produced in Japan, and the overall quality of Korean powdered green tea was poorer than that of Japanese powdered green tea.

The difference of photosynthetic efficiency and electron transport rate by control of the red tide organism using algicidal substance and yellow clay (살조물질과 황토를 이용한 적조생물 제어에 따른광합성 효율 및 전자전달율의 차이)

  • Son, Moonho;Baek, Seung Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2951-2957
    • /
    • 2015
  • The development of worldwide harmful algal blooms(HAB) is a serious problem for public health and fisheries industries. To evaluate the algicidal impact on the HAB species, algicide thiazolidinedione derivative (TD49) and yellow clay were examined, which is focus on assess the algicidal effects and inhibition to photosynthesis of HAB species. To obtain the detailed information, we analyzed the viability of target species related to activity Chl. a, photosynthetic efficiency($F_v/F_m$), and electron transport rate(ETR). Culture experiment was conducted to evaluate the algicidal effects of three harmful species(raphidophyceae Heterosigma akashiwo, Chattonella marina, and dinophyceae Heterocapsa circularisquama) and one non-harmful species (cryptophyceae Rhodomonas salina). Our experiments revealed that three HAB species were easily destroyed of the cell walls after TD49 dosing. Also, they had significantly reducing values of active Chl. a, $F_v/F_m$, and ETR, due to the damage of photosystem II by inter-cellular disturbance. As a result, the algicidal effect(%) for the three HABs were as follows, in the order of greatest to the least: H. circularisquama> C. marina> H. akashiwo. However, the algicidal effect for yellow clay remained to be <30% (p>0.01), implying that it may not have damaged the photosystem II. On the other hand, non-HAB R. salina was promoted at both TD49 and yellow clay treatments. Our results demonstrated that the TD49 is a good agent for the control of HABs H. akashiwo, C. marina, and H. circularisquama, whereas the yellow clay would not be suitable for the field application based on our experimental results.

Time Dependent Evaluation of Corrosion Free Life of Concrete Tunnel Structures Based on the Reliability Theory (해저 콘크리트 구조물의 신뢰성 이론에 의한 시간 의존적 내구수명 평가)

  • Pack, Seung Woo;Jung, Min Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.142-154
    • /
    • 2011
  • This study predicted the probability of corrosion initiation of reinforced concrete tunnel boxes structures using the Monte Carlo Simulation. For the inner wall and outer wall in the tunnel boxes, exposed to airborne chloride ion and seawater directly respectively, statistical values of parameters like diffusion coefficient D, surface chloride content $C_s$, cover depth c, and the chloride threshold level $C_{lim}$ were examined from experiment or literature review. Their average values accounted for $3.77{\times}10^{-12}m^2/s$, 3.0% by weight of cement, 94.7mm and 45.5mm for outer wall and inner wall, respectively, and 0.69% by weight of cement for D, $C_s$, c, and $C_{lim}$, respectively. With these parametric values, the distribution of chloride contents at rebar with time and the probability of corrosion initiation of the tunnel boxes, inner wall and outer wall, was examined by considering time dependency of chloride transport. From the examination, the histogram of chloride contents at rebar is closer to a gamma distribution, and the mean value increases with time, while the coefficient of variance decreases with time. It was found that the probability of corrosion initiation and the time to corrosion were dependent on the time dependency of chloride transport. Time independent model predicted time to corrosion initiation of inner wall and outer wall as 8 and 12 years, respectively, while 178 and 283 years of time to corrosion was calculated by time dependent model for inner wall and outer wall, respectively. For time independent model, the probability of corrosion at 100 years of exposure for inner wall and outer wall was ranged 59.5 and 95.5%, respectively, while time dependent model indicated 2.9 and 0.2% of the probability corrosion, respectively. Finally, impact of $C_{lim}$, including values specified in current codes, on the probability of corrosion initiation and corrosion free life is discussed.

Preliminary Report of Observed Urban - Rural Gradient of Carbon Dioxide Concentration across Seoul, Suwon, and Icheon in South Korea (도시 - 전원간 이산화탄소(CO2) 농도구배 예비관측 결과)

  • Chung, U-Ran;Lee, Kyu-Jong;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.4
    • /
    • pp.268-276
    • /
    • 2007
  • Urban atmosphere may play as a harbinger for the future climate change with respect to temperature and $CO_2$ concentration. The Seoul metropolitan area is unique in rapid urbanization and industrialization during the last several decades, providing a natural $CO_2$ dome with increased temperature. This study was carried out to evaluate the feasibility of using the urban-rural environmental gradient in replacement of the IPCC mid-term scenario (after 30-50 years). For this, we measured atmospheric $CO_2$ concentration and air temperature at three sites with different degree of urbanization (Seoul, Suwon, and Icheon). Results from 11-month measurement can be summarized as follows: (1) The annual mean $CO_2$ concentration across 3 sites was in the order of Seoul (439 ppm) > Suwon (419 ppm) > Icheon (416 ppm), showing a substantial urban-rural environmental gradient. (2) The diurnal fluctuation in $CO_2$ concentration was greater in summer than in winter, showing the effect of photosynthesis on local $CO_2$ concentration. (3) The daily maximum $CO_2$ concentration was observed at 0500 LST in spring and summer, 0800 LST in autumn, and 0900 LST in winter, showing the sunrise-time dependence. (4) The observed hourly maximum $CO_2$ concentration averaged for the whole period was 446 ppm in Seoul at 0700 LST, while the minimum was 407 ppm in Suwon at 1500 LST. (5) Compared with the background atmospheric concentration of $CO_2$ in Anmyeon-do (377.4 ppm annual mean), $CO_2$ concentration of the study sites was higher by 14% in Seoul, by 10% in Suwon, and by 9% in Icheon. The observed $CO_2$ concentration in Seoul reached already 98% of the 2030-2040 projection (450 ppm) and 80% of the 2040-2050 projection (550 ppm) under the IPCC BAU scenario, showing a feasibility of using the $CO_2$ dome of Seoul as a natural experimental setting for the mid-term climate change impact assessment.

Effects of Reclaimed Wastewater and Waste Nutrient Solution Irrigation on Seedling Growth of Chinese Cabbage (하수처리수 및 폐양액의 재이용이 배추 유묘 생장에 미치는 영향)

  • Hong, Ki-Chan;Choi, Bong-Su;Lim, Kyoung-Jae;Won, Jae-Hee;Jeon, Shin-Jae;Hur, Seung-Oh;Ha, Sang-Keun;Kim, Nam-Won;Yang, Jae-E;Ok, Yong-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2009
  • Water shortages are expected to be a major impact of climate change. This study examined the growth of Chinese cabbage seedling using reclaimed wastewater and waste nutrient solution as alternative irrigation resources. Generally, the concentration of nutrients, such as $K^+$, $NH_4^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$,$NO_3^-$, $PO_4^-$ and $SO_4^{2-}$, in waste nutrient solution was higher than that in wastewater. However, Chinese cabbage seedling irrigated with wastewater was supplied a higher concentration of $Na^+$ and $Cl^-$ than waste nutrient solution. The growth of Chinese cabbage seedling irrigated with waste nutrient solution was similar or higher than those irrigated with groundwater as control, while the growth of those irrigated with wastewater was similar to those irrigated with groundwater. The total nitrogen uptake in Chinese cabbage seedling irrigated with groundwater, waste nutrient solution from organic and inorganic hydroponic cultures, and wastewater was 5.47, 10.02, 5.20, and 4.59 mg/plant, respectively. The nitrogen uptake of Chinese cabbage seedling irrigated with waste nutrient solution from organic hydroponic substrates in a 50% lower dose than recommended was 8.34 mg/plant, which is higher than that of the cabbage irrigated with groundwater. Overall, the results suggest that waste nutrient solution and wastewater can be used as alternate water resources, and can allow a reduction in the amount of fertilizer needed to raise Chinese cabbage seedling.

Occurrence Characteristics of Uranium and Radon-222 in Groundwater at ○○ Village, Yongin Area (용인 ○○마을 지하수내 우라늄 및 라돈-222의 산출특성)

  • Jeong, Chan Ho;Yang, Jae Ha;Lee, Yong Cheon;Lee, Yu Jin;Cho, Hyeon Young;Kim, Moon Su;Kim, Hyun Koo;Kim, Tae Seong;Jo, Byung Uk
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.261-276
    • /
    • 2016
  • The occurrence of natural radioactive materials such as uranium and radon-222 in groundwater was examined with hydrogeochemistry and geology at ○○ village in the Yongin area. Two rounds of 19 groundwater and 5 surface water sampling were collected for analysis. The range of pH value in groundwaters was 5.81 to 7.79 and the geochemical types of the groundwater were mostly Ca(Na)-HCO3 and Ca(Na)-NO3(Cl)-HCO3. Uranium and radon-222 concentrations in the groundwater ranged from 0.06 to 411 μg/L and from 5.56 to 903 Bq/L, respectively. Two deep groundwaters used as common potable well-water sources exceeded the maximum contaminant levels of the uranium and radon-222 proposed by the United States Environmental Protection Agency (US EPA). Three groundwater samples from residential areas contained unsuitable levels of uranium, and 12 groundwater samples were unsuitable due to radon-222 concentrations. Radioactive materials in the unsuitable groundwater are naturally occurring in a Jurassic amphibole- and biotite-bearing granitic gneiss. High uranium and radon-222 groundwater concentrations were only observed in two common wells; the others showed no relationship between bedrock geology and groundwater geochemical constituents. With such high concentrations of naturally occurring radioactive materials in groundwater, the affected areas may extend tens of meters for uranium and even farther for radon-222. Therefore, we suggest the radon-222 and the uranium did not originate from the same source. Based on the distribution of radon-222 in the study area, zones of higher radon-222 concentrations may be the result of diffusion through cracks, joint, or faults. Surface radioactivity and uranium concentrations in the groundwater show a positive relationship, and the impact areas may extend for ~200m beyond the well in the case of wells containing high concentrations of uranium. The highest uranium and thorium concentrations in rock samples were detected in thorite and monazite.

Life-Sustaining Procedures, Palliative Care, and Cost Trends in Dying COPD Patients in U.S. Hospitals: 2005~2014

  • Kim, Sun Jung;Shen, Jay;Ko, Eunjeong;Kim, Pearl;Lee, Yong-Jae;Lee, Jae Hoon;Liu, Xibei;Ukken, Johnson;Kioka, Mutsumi;Yoo, Ji Won
    • Journal of Hospice and Palliative Care
    • /
    • v.21 no.1
    • /
    • pp.23-32
    • /
    • 2018
  • Purpose: Little is known regarding the extent to which dying patients with chronic obstructive pulmonary disease (COPD) receive life-sustaining procedures and palliative care in U.S. hospitals. We examine hospital cost trends and the impact of palliative care utilization on the use of life-sustaining procedures in this population. Methods: Retrospective nationwide cohort analysis was performed using National Inpatient Sample (NIS) data from 2005 and 2014. We examined the receipt of both palliative care and intensive medical procedures, defined as systemic procedures, pulmonary procedures, or surgeries using the International Classification of Diseases, 9th revision (ICD-9-CM). Results: We used compound annual growth rates (CAGR) to determine temporal trends and multilevel multivariate regressions to identify factors associated with hospital cost. Among 77,394,755 hospitalizations, 79,314 patients were examined. The CAGR of hospital cost was 5.83% (P<0.001). The CAGRs of systemic procedures and palliative care were 5.98% and 19.89% respectively (each P<0.001). Systemic procedures, pulmonary procedures, and surgeries were associated with increased hospital cost by 59.04%, 72.00%, 55.26%, respectively (each P<0.001). Palliative care was associated with decreased hospital cost by 28.71% (P<0.001). Conclusion: The volume of systemic procedures is the biggest driver of cost increase although there is a cost-saving effect from greater palliative care utilization.

Optimization for Underwater Welding of Marine Steel Plates (선박용 강판의 수중 용접 최적화에 관한 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 1984
  • Optimizing investigation of characteristics of underwater welding by a gravity type arc welding process was experimentally carried out by using six types of domestic coated welding electrodes for welding of domestic marine structural steel plates (KR Grade A-1, SWS41A, SWS41B,) in order to develop the underwater welding techniques in practical use. Main results obtained are summarized as follows: 1. The absorption speed of the coating of domestic coated lime titania type welding-electrode became constant at about 60 minutes in water and it was about 0.18%/min during initial 8 minutes of absorption time. 2. Thus, the immediate welding electrode could be used in underwater welding for such a short time in comparison with the joint strength of in-atmosphere-and on-water-welding by dry-, wet-or immediate-welding-electrode. 3. By bead appearance and X-ray inspection, ilmenite, limetitania and high titanium oxide types of electrodes were found better for underwater-welding of 10 mm KR Grade A-1 steel plates, while proper welding angle, current and electrode diameter were 6$0^{\circ}C$, above 160A and 4mm respectively under 28cm/min of welding speed. 4. The weld metal tensile strength or proof stress of underwater-welded-joints has a quadratic relationship with the heat input, and the optimal heat input zone is about 13 to 15KJ/cm for 10mm SWS41A steel plates, resulting from consideration upon both joint efficiency of above-100% and recovery of impact strength and strain. Meanwhile, the optimal heat input zone resulting from tension-tension fatigue limit above the base metal's of SWS41A plates is 16 to 19KJ/cm. Reliability of all the empirical equations reveals 95% confidence level. 6. The microstructure of the underwater welds of SES41A welded in such a zone has no weld defects such as hydrogen brittleness with supreme high hardness, since the HAZ-bond boundary area adjacent to both surface and base metal has only Hv400 max with the microstructure of fine martensite, bainite, pearlite and small amount of ferrite.

  • PDF

Optical and Physical Properties of Covering Materials for Plastic Greenhouse (플라스틱하우스용 피복재의 광학.물리적 특성)

  • Kwon, Joon Kook;Choi, Young Hah;Park, Dong Kum;Lee, Jae Han;Um, Yeong Cheon;Park, Joong Choon
    • Journal of Bio-Environment Control
    • /
    • v.10 no.3
    • /
    • pp.141-147
    • /
    • 2001
  • To compare to the optical and physical properties of covering materials for plastic greenhouse, EVA(ethylene vinyl acetate, 0.08 mm), polyorefine antifog (0.1 mm), fluoric (0.06 mm), diffused (0.15 mm), polyorefine antidrop (0.15 mm) and PET (polyethylene terephthalate, 0.5 mm) films were used. The small greenhouse (5.4$\times$18.5$\times$2.9 m, W$\times$L$\times$H) investigated during 3 years form 1997 to 1999. After covering materials were used for greenhouse covering during 30 months, UV (300-400 nm) transmittances of diffused film and PET were appeared from 25 to 26%, while those of fluoric film and the other films were 76% and from 63 to 67%. For PAR (photosynthetically active radiation, 400-700 nm), the transmittances of fluoric, antidrop, PET, antifog, EVA, and diffused film were 86.5%, 80.5%, 76.3%, 75.5%, 74.1% and 61.9% respectively. The losses of PAR transmittance of EVA and the antidrop film during period between 7 days and 30 months were higher value 12% and lower value 6% than any other film. Under the canopy of tomato plants, light intensities of the diffused film and the antifog film were 2.5 times and 1.4 times higher than those of PET. Tensile resistances of fluoric film at the break point were the higher than those of antifog film and diffused film. While impact resistance of the antidrop film was the highest value, but the fluoric film was the lowest. Air temperature inside the greenhouse for the day showed to be changed the similar light transmittance of the films. But the increasing order of air temperature for the night was PET, fluoric, antidrop, diffused, antifog and EVA film. Especially, air temperature in the PET was 4$^{\circ}C$ higher than that in the EVA. Solar radiations of the fluoric film, the antidrop film, PET and antifog film in the greenhouse were 32%, 15%, 11% and 4% higher than those of PET. However, those of the diffused film was 7% less than PET.

  • PDF

Impacts of Impoundments by Low-head and Large Dams on Benthic Macroinvertebrate Communities in Korean Streams and Rivers (소형 보와 대형 댐에 의해 형성된 저수역이 저서성 대형무척추동물 군집에 미치는 영향)

  • Kil, Hye-Kyung;Kim, Dong-Gun;Jung, Sang-Woo;Jin, Young-Hun;Hwang, Jeong-Mi;Bae, Kyung-Seok;Bae, Yeon-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.190-198
    • /
    • 2010
  • This study was conducted to examine the effects of dams on benthic macroinvertebrate communities in Korean streams and rivers. Four low-head dams and three large dams were studied throughout South Korea. Sampling was taken at immediately upper (impoundment), lower (riffle area), and control (riffle area) sites from the dams during 2004-2007. The upper sites, of which substrate heterogeneity and velocity were relatively low, showed a lower degree of species richness, density, and diversity indices, which is very different from the lower and control sites. Heavily polluted streams showed a lesser degree of community differences between the upper and lower sites. In the large dams, the upper and lower sites showed very low values of species diversity indices and very high values of dominance indices compared to the control sites. In the low-head dams, however, the difference of degree of the values was relatively smaller. Compositions of the functional feeding groups and the habitat orientation groups were relatively simpler at the upper sites than at the lower sites and the degree of difference was greater in the large dams. Species richness and community indices of benthic macroinvertebrates were more significantly affected by habitat characteristics than water quality at the upper sites; however, those were more significantly related with water quality at the lower sites. In conclusion, large and low-head dams could simplify stream habitats particularly at the upper sites (impoundment), and they negatively affected on the benthic macroinvertebrate communities inhabited the habitats. The impact was larger in the large dams than in the low-head dams.