• Title/Summary/Keyword: IMA

Search Result 153, Processing Time 0.036 seconds

Free vibration of a rectangular plate with an attached three-degree-of-freedom spring-mass system

  • Febbo, M.;Bambill, D.V.;Rossi, R.E.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.5
    • /
    • pp.637-654
    • /
    • 2011
  • The present paper studies the variation of the natural frequencies and mode shapes of rectangular plates carrying a three degree-of-freedom spring-mass system (subsystem), when the subsystem changes (stiffness, mass, moment of inertia, location). An analytical approach based on Lagrange multipliers as well as a finite element formulation are employed and compared. Numerically reliable results are presented for the first time, illustrating the convenience of using the present analytical method which requires only the solution of a linear eigenvalue problem. Results obtained through the variation of the mass, stiffness and moment of inertia of the 3-DOF system can be understood under the effective mass concept or Rayleigh's statement. The analysis of frequency values of the whole system, when the 3-DOF system approaches or moves away from the center, shows that the variations depend on each particular mode of vibration. When the 3-DOF system is placed in the center of the plate, "new" modes are found to be a combination of the subsystem's modes (two rotations, traslation) and the bare plate's modes that possess the same symmetry. This situation no longer exists as the 3-DOF system moves away from the center of the plate, since different bare plate's modes enable distinct motions of the 3-DOF system contributing differently to the "new' modes as its location is modified. Also the natural frequencies of the compound system are nearly uncoupled have been calculated by means of a first order eigenvalue perturbation analysis.

Multi-dimentional Correction of the Scarf Osteotomy for the Treatment of Hallux Valgus (무지 외반증에 시행한 Scarf 절골술의 3차원적 변형 교정력에 관한 연구)

  • Moon, Gi-Hyuk;Ahn, Gil-Yeong;Yun, Ho-Hyun;Lee, Yeong-Hyun;Lee, Jung-Ick;Nam, Il-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2007
  • Purpose: Scarf osteotomy can provide the simultaneous correction of the hallux valgus angle (HVA), 1-2 intermetatarsal angle ($IMA_{1-2}$), DMAA and the plantar displacement of the fragment. The study was conducted to understand the multi-dimensional correction of the hallux valgus. Materials and Methods: Fourty eight patients who had undergone Scarf osteotomy with hallux valgus at more than $30^{\circ}$ of HVA and more than $15^{\circ}$ of $IMA_{1-2}$ were studied. Before an osteotomy, a reference K-wire was inserted to the 1st metatarsal head. After the osteotomy, the plantar fragment was moved laterally and the proximal end of the fragment was forced beyond the distal end which resulted in an internal rotation of the head fragment to correct the DMAA. Results: The HVA improved an average of $33.3^{\circ}$ to $7.7^{\circ}$ with the IMA1-2 respectively from $15.4^{\circ}$ to $6.5^{\circ}$. The DMAA improved an average of $19.5^{\circ}$ ($5.2-30.9^{\circ}$) to $4.5^{\circ}$ ($0.4-13.8^{\circ}$). By checking the angle, which was at an average of $25^{\circ}$ between the plantar surface of the foot and the osteotomy plane, the average distance of 1.9 mm (1.18-3.1 mm) of plantar displacement was measured using the value of sine (sin 25 = 0.422). Conclusions: It is possible to correct the HVA, IMA1-2 and DMAA simultaneously with one osteotomy making the lateral shift, the internal rotation and the plantar displacement of the plantar head fragment as desired. Despite the technicality and difficulty of the Scarf osteotomy, once familiarized through myriad procedures, all disadvantages are outweighed by the success and satisfaction of both patient and surgeon.

  • PDF

A Study of FC-NIC Design Using zynq SoC for Host Load Reduction (호스트 부하 경감 달성을 위한 zynq SoC를 적용한 FC-NIC 설계에 관한 연구)

  • Hwang, Byeung-Chang;Seo, Jung-hoon;Kim, Young-Su;Ha, Sung-woo;Kim, Jae-Young;Jang, Sun-geun
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.423-432
    • /
    • 2015
  • This paper shows that design, manufacture and the performance of FC-NIC (fibre channel network interface card) for network unit configuration which is based on one of the 5 main configuration items of the common functional module for IMA (integrated modular Avionics) architecture. Especially, FC-NIC uses zynq SoC (system on chip) for host load reductions. The host merely transmit FC destination address, source memory location and size information to the FC-NIC. After then the FC-NIC read the host memory via DMA (direct memory access). FC upper layer protocol and sequence process at local processor and programmable logic of FC-NIC zynq SoC. It enables to free from host load for external communication. The performance of FC-NIC shows average 5.47 us low end-to-end latency at 2.125 Gbps line speed. It represent that FC-NIC is one of good candidate network for IMA.

Treatment of Hallux Valgus with Metatarsal Double Osteotomy and Longitudinal Pin Fixation (중족골 이중절골술 및 K-강선을 사용한 종 고정술에 의한 무지외반증의 치료)

  • Sohn, Sung-Keun;Kim, Sung-Soo;Kim, Chul-Hong;Lee, Myung-Jin;Kang, Jin-Hun;Lee, Chan-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.223-229
    • /
    • 2006
  • Purpose: The purpose of this study was to analyze the results of the treatment of hallux valgus with metatarsal double osteotomy and longitudinal pin fixation. Materials and Methods: We reviewed 19 patients (21 feet) who had been treated by metatarsal double osteotomy and longitudinal pin fixation for the moderate or severe hallux valgus with increased distal metatarsal articular angle (DMAA), between 1999 and 2004. They were followed prospectively for a minimum of 20 months. Functional outcomes were measured via Hallux metatarsophalangeal-Interphalangeal (HMI) scale and Mayo clinic forefoot scoring system (FFSS). Radiographically, we assessed pre, postoperative and at the last follow-up, the hallux valgus angle (HVA), 1st and 2nd intermetararsal angle (IMA), DMAA. Results: The average preoperative HVA, IMA, DMAA measured $36.76^{\circ}$, $13.62^{\circ}$, $26.00^{\circ}$, respectively. At the last follow-up, HVA, IMA, DMAA measured $9.57^{\circ}$, $7.14^{\circ}$, $9.33^{\circ}$. The correction of HVA, IMA, DMAA were $27.19^{\circ}$, $6.48^{\circ}$, $6.67^{\circ}$. At the last follow-up, there were no recurrences and complications, except two patients complained of unsatisfactory stiffness in the 1st metatarsophalangeal joint and subjectively rated their results as fair. The others rated that as excellent or good. At the last follow-up, statistically, the mean HMI scale and FFSS improved significantly from pre-operative score. Conclusions: In the treatment of moderate or severe hallux valgus with increased DMAA by metatarsal double osteotomy and longitudinal pin fixation, we had good functional and radiological results without recurrences and significant complications. But the stiffness in the 1st metatarsophalangeal joint warrants further study.

  • PDF

Molecular Cloning and Expression of Heat-stable Enterotoxin Gene from Swine Enterotoxigenic Escherichia coli (돼지에서 유래한 병원성 대장균의 내열성 장독소 생산유전자의 Cloning 및 발현)

  • 김교창;도대흥
    • Journal of Food Hygiene and Safety
    • /
    • v.6 no.3
    • /
    • pp.147-155
    • /
    • 1991
  • Enterotoxigenic E. coli is one of the major causative agents of the infantile diarrhea and traveler's diarrhea. The heat-stable enterotoxin(ST) is thought to be a virulence factor in the pathogenesis of the diarrhea and to be a maker for identification of the enterotoxingeic E. coli from non pathogenic E. coli. The isolate of enterotoxigenlc E. coli was isolated from swine during 1989 year(from 5 to 10 month) in the Kyong-gi and Chung-Cheong provinces, and three strains(KM-4, KM-7 and KM-12) was selected from 189 isolates of ST producing E. coli. The detection of a ST produced of the isolated E. coli was performed by the infant mouse assay(IMA). This study was designed to know optimal conditions for the production of the ST and the molecular properties of plasmids of the enterotoxigenic E. coli. Amount of ST produced were the most at initial pH 8.5~9.0 of succinate salts medium culture. The cultural time of the same medium was accumulated the highest level of ST was at the 14 to 16 hours, and then stationary phase was at the 20 hours. From this experiment the KM-7 strain was selected among ST producing strains by IMA. Partial plasmid-curing experiment was done to select plasmid encoding for ST among other plasmids and then comparing the plasmid pattern of ST producing strain(KM-7) with those of other ST non-producing strains, it is found that ST gene exists on the about 80 Kbp plasmid. Each fragment of this plasmid digested with EcoRl was ligated to vector pBR 322 and transformed into E. coli K-12. A clone producing ST(eKT 53) was selected by IMA. The EcoRl digestion pattern of the isolated plasmid(pKD 37) from the ST producing clone it is indicated that the size of the inserted fragment in eKT 53 strain is 16 Kbp. The cultured supernatant of eKT 53 strain was positive result of ST production in IMA.

  • PDF

Measurement of the Angle related Hallux Valgus in Normal Korean Adults (무지외반증에서 한국인의 정상 방사선각도 계측치에 대한 연구)

  • Lee, Kyung-Tai;Song, Joon-Sub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.11-14
    • /
    • 1997
  • Hallux valgus is a complex deformity which contains static subluxation of the first metatarsophalangeal joint with lateral deviation of the great toe and medial deviation of the first metatarsal bone. Among the several parameters, radiographic indices are the important ones in the choice of the treatment method. Even though, the normal values of the western peoples are already estabilished, there was no standard values for Korean who has different genetics, and cultural background, till now. So, we tried to estimate the noraml values of the HVA (hallux valgus angle ), IMA ( Intermetatarsal angle) and DMAA (Distal Metatarsal Articular surface Angle) in a normal adult. Fifty normal adult (each 25 male and female) were chosen and took 100 cases of foot radiograph and radiologic indices of the hallux valgus were measured. Average age at the investigation was 34.5 years old. The average HVA is $13.3^{\circ}$, IMA is $8.5^{\circ}$ and DMAA is $34.6^{\circ}$.

  • PDF

Development of Integrated Variable Sampling Interval EngineeringProcess Control & Statistical Process Control System (가변 샘플링간격 EPC/SPC 결합시스템의 개발)

  • Lee, Sung-Jae;Seo, Sun-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.3
    • /
    • pp.210-218
    • /
    • 2006
  • Traditional statistical process control (SPC) applied to discrete part industry in the form of control charts can look for and eliminate assignable causes by process monitoring. On the other hand, engineering process control (EPC) applied to the process industry in the form of feedback control can maintain the process output on the target by continual adjustment of input variable. This study presents controlling and monitoring rules adopted by variable sampling interval (VSI) to change sampling intervals in a predetermined fashion on the predicted process levels under integrated EPC and SPC systems. Twelve rules classified by EPC schemes(MMSE, constrained PI, bounded or deadband adjustment policy) and type of sampling interval combined with EWMA chart of SPC are proposed under IMA (1,1) disturbance model and zero-order (responsive) dynamic system. Properties of twelve control rules under three patterns of process change (sudden shift, drift and random shift) are evaluated and discussed through simulation and control rules for integrated VSI EPC and SPC systems are recommended.

A Readjustment Procedure after Signalling in the Integrated Process Control (통합공정관리에서 재수정 절차)

  • Park, Chang-Soon;Lee, Jae-Heon
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.3
    • /
    • pp.429-436
    • /
    • 2009
  • This paper considers the integrated process control procedure for detecting special causes in an IMA(1,1) process that is being adjusted automatically after each observation using a minimum mean squared error adjustment policy. When the control chart signals after the occurrence of a special cause, the special cause will be detected and eliminated from the process by the rectifying action. However, when the elimination of the special cause costs high or is not practically possible, an alternative action is to readjust the process with appropriately modified adjustment scheme. In this paper, we propose the readjustment procedure after having a true signal, and show that the use of the readjustment can reduce the deviation of a process from the target.