• Title/Summary/Keyword: ILI

Search Result 33, Processing Time 0.028 seconds

Analysis of Influenza Virus Isolates in Seoul during 2003-2004 Season (2003-2004 절기 서울지역의 인플루엔자 바이러스 분리 및 아형 분석)

  • Hwang Young-Ok;Lee Jae-In;Seo Byung-tae
    • Korean Journal of Microbiology
    • /
    • v.41 no.1
    • /
    • pp.53-59
    • /
    • 2005
  • Influenza is an important public health problem which occurs almost every winter in temperate climates and is often associated with increased rates of hospitalization and death. In 1999, our influenza surveillance was initiated with 4 voluntary sentinel physicians and the Public Health Center. During the 2003-2004 influenza season, 124 influenza viruses were isolated from 401 clinical specimens, which were collected from patients with Influenza-like illness(ILI) in Seoul. The case definition of ILI is a case with fever more than $38^{\circ}C$ and systemic symptoms; cough, or sore throat. ILI was the highest at the 20-49 age $group(23\%)$ and the rate of virus isolation was the highest at the 7-19 age $group(50\%)$. Among 124 influenza viruses, isolates 83 were identified as A/H3N2 type and others were subtyped as influenza B viruses in 2003-2004 season. Influenza viruses were collected $39.1\%$ at Nowon-Gu, $13.5\%$ Gangnam-Gu and Seocho-Gu etc. and the isolate rate of virus had the area difference; Yongsan-Gu $66.7\%$, Gangnam-gu $50.0\%$, Nowon-Gu $39.9\%$, Kangbuk-Gu $36.8\%$, Seocho-Gu $27.8\%$, Dongjak-Gu $21.2\%$. Out of 401 individuals, 160 was vaccinated $(40\%)$ and the vaccination rate was the highest at the 20-49 age $group(32\%)$. These findings may contribute to the recommondation of the influenza vaccine formulation and the development of influenza control measure.

A Prediction Method of the Gas Pipeline Failure Using In-line Inspection and Corrosion Defect Clustering (In-line Inspection과 부식결함 클러스터링을 이용한 가스배관의 고장예측)

  • Kim, Seong-Jun;Choe, Byung Hak;Kim, Woosik
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.6
    • /
    • pp.651-656
    • /
    • 2014
  • Corrosion has a significant influence upon the reliability assessment and the maintenance planning of gas pipeline. Corrosion defects occurred on the underground pipeline can be obtained by conducting periodic in-line inspection (ILI). However, little study has been done for practical use of ILI data. This paper deals with remaining lifetime prediction of the gas pipeline in the presence of corrosion defects. Because a pipeline parameter includes uncertainty in its operation, a probabilistic approach is adopted in this paper. A pipeline fails when its operating pressure is larger than the pipe failure pressure. In order to estimate the failure probability, this paper uses First Order Reliability Method (FORM) which is popular in the field of structural engineering. A well-known Battelle code is chosen as the computational model for the pipe failure pressure. This paper develops a Matlab GUI for illustrating failure probability predictions Our result indicates that clustering of corrosion defects is helpful for improving a prediction accuracy and preventing an unnecessary maintenance.

Efficacy of Korean Red Ginseng in the Treatment of Alopecia Areata

  • Oh, Ga-Na;Son, Sang-Wook
    • Journal of Ginseng Research
    • /
    • v.36 no.4
    • /
    • pp.391-395
    • /
    • 2012
  • Alopecia areata (AA) is an autoimmune disease that can affect any hair-bearing area. AA is known to be caused by immunological disorder but still, the pathogenesis is not fully understood. Many therapeutic modalities have been used to treat alopecia areata, with variable efficacy and safety profiles. Unfortunately, none of these agents is definitely curative or preventive alone. We studied hair growth efficacy and safety of Korean red ginseng (KRG) in AA comparing corticosteroid intra-lesional injection (ILI) alone patient group with ILI with KRG taking patient group using Folliscope 2.5 for 12 wk. Herein, we would like to report the efficacy of KRG in the treatment of AA and recommend KRG as a useful complimentary food for gaining efficacy of treatment for AA.

Epidemiological Characteristics of Influenza in Children during the 2017-2018 and 2018-2019 Influenza Seasons in Jeju, Korea (2017-2018, 2018-2019 절기 제주 지역 소아 인플루엔자의 역학적 특성)

  • Kim, Yoon-Joo;Choe, Young June;Choi, Jae Hong
    • Pediatric Infection and Vaccine
    • /
    • v.27 no.3
    • /
    • pp.171-179
    • /
    • 2020
  • Purpose: In Korea, seasonal influenza is an important respiratory illness afflicting children every year. We aimed to investigate the childhood epidemiology in Jeju during the 2017-2018 and 2018-2019 seasons. Methods: Children aged <13 years, who were tested for influenza at the Jeju National University Hospital during the 2017-2018 and 2018-2019 influenza seasons, were included. Demographics and the influenza test results were retrospectively reviewed from their medical records. Results: This study included 5,219 cases of influenza-like illness (ILI) (2017-2018: n=2,279; 2018-2019: n=2,940). The mean age of the eligible children was 2.85±2.79 years, and the most common age among ILI patients in each season was 1 year group. There were 902 (17.3%, 902/5,219) confirmed influenza cases during the 2 seasons. The rate of influenza confirmed by rapid influenza diagnostic test or polymerase chain reaction among ILI patients in the 2017-2018 and 2018-2019 seasons was 10.4% (236/2,279) and 10.3% (303/2,940) for influenza A, and 9.1% (208/2,279) and 5.3% (155/2,940) for influenza B, respectively. The mean age of influenza-confirmed cases was 4.09 years and 5.05 years in the 2017-2018 and 2018-2019 seasons, respectively (P<0.05). Weekly distribution of influenza was similar to that of ILI in the clinical sentinel surveillance system in both seasons. Conclusion: The difference in the influenza epidemic trend and age-group distribution between the 2017-2018 and 2018-2019 seasons was distinct in Jeju. Steady epidemiological studies on influenza in Jeju are needed for comparison with other regions of Korea.

Synthesis and Crystal Structures of Alkali Lithium Molybdates and Alkali Lithium Tungstates (알칼리 리치움 몰리브덴산염과 알칼리 리치움 텅그스텐산염의 합성과 결정구조)

  • 정수진
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.3
    • /
    • pp.72-76
    • /
    • 1985
  • Single crystals of the compound MeI $(LiMoO_4)$ and $Me^I(LiWO_4)$ ($Me^I=K$, Rb, Cs) were synthesized by slow evaporation from aqueous solution and bycooling from melt. The compounds of potassium or rubidium are hygroscopic and they form easily hydrated crystals $Me^I LiMoO_4$.$H_2O$ or $Me^ILiMoO_4$.$H_2O$ or $Me^ILiWO_4$.$H_2O$ from aqueous solution. The structures of these hydrated crystals are each other isotypic and they are built up of distorted layers of $(LiMoO_5)$ or $(LiWO_5)$. There exist two types of tetrahedral framework structures in this group of anhydrous molybdates and tung-states ; tridymite-type and cristobalite-type. $KLiMoO_4$ and $KLiWO_4$ have two types of polymorphic structures where as only the cristobalite-type is found in the Rb-and Cs-compounds. The system $KLiSO_4-KLiMoO_4$ was studied. Two components are almost immiscible but there eixst a narrow area of solid solution on the side of sulfate in the system.

  • PDF

Design and Implementation of 30" Geometry PIG

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.629-636
    • /
    • 2003
  • This paper introduces the developed geometry PIG (Pipeline Inspection Gauge), one of several ILI (In-Line Inspection) tools, which provide a full picture of the pipeline from only single pass, and has compact size of the electronic device with not only low power consumption but also rapid response of sensors such as calipers, IMU and odometer. This tool is equipped with the several sensor systems. Caliper sensors measure the pipeline internal diameter, ovality and dent size and shape with high accuracy. The IMU (Inertial Measurement Unit) measures the precise trajectory of the PIG during its traverse of the pipeline. The IMU also provide three-dimensional coordination in space from measurement of inertial acceleration and angular rate. Three odometers mounted on the PIG body provide the distance moved along the line and instantaneous velocity during the PIG run. The datum measured by the sensor systems are stored in on-board solid state memory and magnetic tape devices. There is an electromagnetic transmitter at the back end of the tool, the transmitter enables the inspection operators to keep tracking the tool while it travels through the pipeline. An experiment was fulfilled in pull-rig facility and was adopted from Incheon LT (LNG Terminal) to Namdong GS (Governor Station) line, 13 km length.

COMMON FIXED POINT THEOREMS FOR MAPPINGS ON CONE METRIC SPACES

  • Kim, Jeong-Jin;Bae, Jong-Sook;Cho, Seong-Hoon
    • Journal of applied mathematics & informatics
    • /
    • v.30 no.5_6
    • /
    • pp.1067-1075
    • /
    • 2012
  • In this paper we generalize the results of Ili$\acute{c}$ and Rako$\check{c}$evi$\acute{c}$. Also, we generalize one of Berinde's results to cone metric spaces. And we introduce the notion of compatible mappings of type (BC), and we establish a common fixed point theorem for these mappings.

Feasibility Study on the Utilization of EMAT Technology for In-line Inspection of Gas Pipeline

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Rho, Yong-Woo;Kim, Hak-Joon;Kim, Dae-Kwang;Song, Sung-Jin;Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • If gas is leaking out of gas pipelines, it could cause a huge explosion. Accordingly, it is important to ensure the integrity of gas pipelines. Traditionally, over the years, gas-operating companies have used the ILI system, which is based on axial magnetic flux leakage (MFL), to inspect the gas pipelines. Relatively, there is a low probability of detection (POD) for the axial defects with the axial MFL-based ILI. To prevent the buried pipeline from corrosion, it requires a protective coating. In addition to the potential damage to the coating by environmental factors and external forces, there could be defects on the damaged coating area. Thus, it is essential that nondestructive evaluation methods for detecting axial defects (axial cracks, axial groove) and damaged coating be developed. In this study, an electromagnetic acoustic transducer (EMAT) sensor was designed and fabricated for detecting axial defects and coating disbondment. In order to validate the performances of the developed EMAT sensor, experiments were performed with specimens from axial cracks, axial grooves, and coating disbondment. The experimental results showed that the developed EMAT sensor could detect not only the axial cracks (minimum 5% depth of wall thickness) and axial grooves (minimum 10% depth of wall thickness), but also the coating disbondment.

Inversion in the Centering Framework

  • Joh, Yoon-Kyoung
    • Language and Information
    • /
    • v.17 no.1
    • /
    • pp.17-32
    • /
    • 2013
  • Birner (1998) analyzes the construction of inversion within the centering theory, claiming that the preposed constituent in the inversion structure represents the backward-looking center that connects the current utterance to the previous discourse. However, this paper refutes such a strong claim, pointing out various problems of her work. Instead, this paper argues that the preposed element in the inversion construction is merely the preferred center under the condition that the ranking of the forward-looking centers is determined by the surface word order, rather than by grammatical relations. Thus, this paper claims that the discourse function of the construction of inversion is not text development but merely prominence-giving, in the sense of Ili$\acute{c}$ (1998).

  • PDF

Minimum Period of Data Collection for the Determination of Average Water Pressure in the Water Distribution Networks (배수구역의 평균수압결정을 위한 최소수압측정기간)

  • Hyun, In-Hwaan;DockKo, Seok;Kim, Duck-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.573-580
    • /
    • 2010
  • Average pressure in a pipe network is one of critical factors to estimate the flow distribution and to calculate UARL (Unavoidable Annual Real Losses) value in ILI (Infrastructure Leakage Index). While its collection period and measuring location are essential to obtain average pressure, their standard method have not been established so far. In this study, proper method including its procedure for data collection period and measuring point for average pressure were suggested using non-exceedance probability concept in the water distribution network.