• 제목/요약/키워드: IFA

검색결과 204건 처리시간 0.019초

A Study on Serologic Diagnosis for Dengue Virus Infection

  • Sang-Wook Park;Je-Hoon Yang;Hyung-Joon Bae;Hi-Joo Moon;Young-Dae Woo
    • 대한의생명과학회지
    • /
    • 제8권4호
    • /
    • pp.269-273
    • /
    • 2002
  • Dengue fever (DF) is an acute febrile illness caused by dengue viruses in the family Flaviviridae, genus Flavivirus. DF has so far posed any problem in Korea, however it has been recently believed to be associated with oversea's traveler infected with dengue virus. Antibody titers of sera from DF patients against dengue virus were measured by indirect immunofluorescence assay (IFA) and plaque reduction neutralization test (PRNT), including the haematologic test. Three of patients with DF showed highly fluorescent and neutralizing antibody titers by IFA and PRNT assay. Two of them showed higher, remarkably. Meanwhile, one of them was tested and resulted in severe tirombocytopenia, elevated serum levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT) activities as well as mild leucopenia, increased monocytes and basophils and depressed lymphocytes in haematological differential count.

  • PDF

3중밴드 GSM용 폴더폰 IFA 설계 (Design of a Folder Phone IFA for the Triple Band GMS Mobile Phone)

  • 박용수;정학주;김주만;손태호
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2008년도 추계학술발표논문집
    • /
    • pp.207-210
    • /
    • 2008
  • 본 논문에서는 휴대폰 GSM850/1800/1900 대역용 폴더폰 IFA를 설계하고 이를 제작하였다. 안테나의 전류 밀도의 증가를 위해 브랜치 구조로 설계함으로서 안테나의 효율 증가를 야기 시킨다. 안테나 효율 증가에 대한 실험은 기존의 GSM850/1800/1900 대역에 사용하는 휴대폰에 적용하여 제반 특성을 측정한다. 측정결과 폴더 닫힘 때 1.22dB, 폴더 열림 때 1.35dB 향상됨을 보인다.

  • PDF

휴대폰 3중 대역 내장형 안테나 설계 (Design of Triple-band Internal Antenna for the Mobile Phone)

  • 오규종;손태호
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.171-174
    • /
    • 2011
  • 본 논문에서는 휴대단말기의 효율적인 이용을 위하여 GSM/DCS/PCS대역에서 사용할 수 있는 변형된 IFA 형태의 내장형 안테나를 설계하고 이를 제작하였다. 실제 상용화된 휴대단말기 내장형 안테나에 3D Tool을 이용하여 전류 흐름의 상쇄작용을 고려하여 3중 대역을 형성시켰으며, Stub 길이의 변화에 따르는 반사손실의 특성을 확인하였다. 설계된 안테나를 제작하여 측정한 결과는 기존의 안테나 보다 약 10.9% 1.57dB특성이 개선되었음을 확인하였으며, 넓은 주파수 대역으로 인하여 통신의 편리성을 확인하였다.

Analytical criteria for fuel fragmentation and burst FGR during a LOCA

  • Khvostov, G.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2402-2409
    • /
    • 2020
  • Analytical criteria for the onset of fuel fragmentation and Burst Fission Gas Release in fuel rods with ballooned claddings are formulated. On that basis, the GRSW-A model integrated with a fuel behaviour code is updated. After modification, the updated code is successfully applied to simulation of the Halden LOCA test IFA-650.12. Specifically, the calculation with Burst Fission Gas Release during the test resulted in prediction of cladding failure, whereas it could not be predicted at the test planning, before new models were implemented. A good agreement of the current model with experimental data for transient Fission Gas Release in the tests IFA-650.12 and IFA-650.14 is shown, as well.

Insights into fuel behaviour during relatively fast thermal transients based on calculations for two tests of the Halden IFA-507 experiment

  • Grigori Khvostov
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3801-3807
    • /
    • 2023
  • Outcomes of the project "Comprehensive Verification of the FALCON Code for Calculation of Nuclear Fuel Temperature" relating to calculation of fuel temperature during relatively fast thermal transients are presented. Good prediction capabilities of the FALCON MOD01 code coupled with the GRSW-A code are shown as applied to the data of the TF3 and TF5 tests from the Transient Temperature Experiment IFA-507. The IFA-507 related dataset of the OECD/NEA International Fuel Performance Experiments (IFPE) Database is extended by the reconstructed dynamics of the axial power distribution in the rods during the transient phase of the experiment. Based on the code calculation, the time constant of the thermal fuel response to a power transient is estimated.

간접형광항체법을 이용한 닭 로타바이러스의 혈청역가 조사 (Serological studies of avian rotaviruses in chicken sera using indirect immunofluorescence assay)

  • 김혜경;곽학구;박경재;안재문;강신영
    • 한국동물위생학회지
    • /
    • 제22권4호
    • /
    • pp.385-392
    • /
    • 1999
  • A total of 420 chicken sera from various regions were tested for the presence of antibodies to avian rotavirus using indirect immunofluorescence assay (IFA). In broiler farms, rotavirus antibodies were detected from 20 farms among 30 farms tested and the positive rates were above 50% in 9 farms. In parent stock farms, rotavirus antibodies were detected from 5 farms among 14 farms tested. From sera collected in 7 layer farms rotavirus antibodies were not detected.

  • PDF