• Title/Summary/Keyword: IEC61850

Search Result 214, Processing Time 0.029 seconds

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

A Study on the design of Process bus for distribution line integration IED in digital substation (디지털변전소 배전선로 통합 IED용 Process bus 설계에 관한 연구)

  • Kim, Seok-kon;An, Yong-ho;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.53-54
    • /
    • 2015
  • 기존의 IEC 61850 표준 적용 국내 디지털변전소는 Station 레벨에 한정되어 구축되어 왔다. 향후 구축될 Process 레벨을 포함한 풀(Full) 디지털 변전소 디지털화는 디지털변전소 운전에 있어 중요하고 긴급한 신호인 Process bus를 통한 SV와 GOOSE신호의 전송으로 이루어지고 있다. Process bus를 활용한 배전선로 보호용 통합 IED는 GIS 등 변전소 전력설비로부터 전압과 전류 값을 MU(Merging Unit)를 통해 공급받아 각 구간의 Bay 혹은 Bank단위로 통합적인 보호 기능을 수행하고, 주 IED와 예비 IED가 서로의 상태를 상호 감시하여 보호기능의 이중화를 이루어야 하고, Sampled Value를 처리하기 위한 정밀한 시각동기화 기능을 갖추어야 한다. 만약, Process bus 시스템의 문제로 인해, 지연과 손실이 발생한다면 변전소 보호 제어에 영향을 줄 수 있으므로 Process bus를 디지털변전소에 적용하기 위해서는 Process bus 기반의 네트워크시스템에 연결된 MU와 IED가 송수신하는 SV와 GOOSE를 손실과 지연없이 전송할 수 있는지를 분석해야 한다. 본 연구에서는 디지털변전소 네트워크 시뮬레이션 시험을 통해, 배전선로용 통합 IED의 성능검증을 위해 Process bus 네트워크 시스템을 설계하고 시뮬레이션 시험을 수행하여 이를 통해 향후 국내의 Process bus 디지털변전시스템 구축을 위한 효과적인 네트워크 시스템 설계방법을 제시하고자 한다.

  • PDF

PTP Management Node-based Time Synchronization Error Detection and Recovery System (PTP Management Node 기반 시각동기 오류 검출 및 대응 시스템)

  • Kim, Yoon Hyun;Son, Kyou Jung;Seo, Young Duk;Chang, Tae Gyu
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.248-253
    • /
    • 2020
  • This paper proposed PTP(Precision Time Protocol) management node-based time synchronization error detection and recovery system. The proposed system is to maintain the preciseness of time synchronization under time synchronization error situations on IEEE 1588-based network environment. To demonstrate the proposed time synchronization error detection and recovery system, PTP implemented EVM(Evaluation Module)-based experiments were performed. As a results of the experiments, it is shown that the proposed system effectively maintains the preciseness of time synchronization under time synchronization error situations.

A Study on Simulation Analysis for the Transmission Delay on the Process bus network in IEC 61850 Digital Substation (디지털변전소 통합 IED 용 Process Bus 네트워크 통신지연 시뮬레이션 연구)

  • Kim, Seok-Kon;An, Yong-Ho;Jang, Byung-Tae;Choi, Jong-Kee;Lee, Nam-Ho;Han, Jung-Yeol;Lee, You-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.18-22
    • /
    • 2015
  • Digitalization of the substation in Korea has been in progress so far with focusing on Station Bus. However, its application to Process Bus has been delayed due to some technical issues. IEDs based on Process Bus use the data values of SV and GOOSE. As the size of communication data on Process Bus is comparatively bigger than that of Station Bus, it is very important for the evaluating the performance of Process Bus to analyze the transferring speed and quality of data from the first equipment, which is located on process level, to station level. According to the results of related studies, it is said that the most important factor for the design and operation of Process Bus network is the communication delay with consideration of the volume of packets. In the paper, the results of performance test for the network with and without application of VLAN on Process Bus system that uses integrated IEDs are presented. Additionally, the paper proposes the optimal method to analyze the communication delays of network systems through evaluating the maximum delay time, link process ratio and the amount of lost packets by using a simulation tool.