• Title/Summary/Keyword: IEC Standard

Search Result 851, Processing Time 0.026 seconds

Improvement of Anti-Collision Performance in ISO/IEC 18000-6 Type B Protocol of the 900MHz RFID System (900MHz RFID 표준 프로토콜(ISO/IEC 18000-6 type B)에서의 충돌방지 성능 개선)

  • Kwon Dae-Ken;Kim Wan-Jin;Kim Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5C
    • /
    • pp.540-547
    • /
    • 2006
  • This paper proposes a novel anti-collision method for the ISO/IEC 18000-6 type B protocol which is the standard protocol of the 900 MHz RFID system. We improve the anti-collision performance by reducing the transmission number of commands and the length of bits required for multi-tag identification in the ISO/IEC 18000-6 type B protocol. Simulation results show that the proposed method improves the multi-tag identification time by 21.7% over the conventional method, irrespective of number of tags.

A Fully Integrated CMOS Security-Enhanced Passive RFID Tag

  • Choi, Suna;Kim, Hyunseok;Lee, Sangyeon;Lee, Kangbok;Lee, Heyungsub
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.141-150
    • /
    • 2014
  • A fully integrated CMOS security-enhanced passive (SEP) tag that compensates the security weakness of ISO/IEC 18000-6C is presented in this paper. For this purpose, we propose a security-enhanced protocol that provides mutual authentication between tag and reader. We show that the proposed protocol meets the security demands of the ongoing international standard for RFID secure systems, ISO/IEC 29167-6. This paper fabricates the SEP tag with a 0.18-${\mu}m$ CMOS technology and suggests the optimal operating frequency of the CMOS SEP tag to comply with ISO/IEC 18000-6C. Furthermore, we measure the SEP tag under a wireless environment. The measured results show that communications between the SEP tag and reader are successfully executed in both conventional passive and SEP modes, which follow ISO/IEC 18000-6C and the proposed security enhanced protocol, respectively. In particular, this paper shows that the SEP tag satisfies the timing link requirement specified in ISO/IEC 18000-6C.

Implementation and Performance Evaluation of Digital Flickermeter Algorithm According to IEC61000-4-15 Edition 2 for Korean Distribution Power System (국내 계통 특성을 고려한 IEC61000-4-15 Edition 2 기반의 디지털 플리커 미터 알고리즘 구현 및 평가)

  • Shin, Hoon-Chul;Han, Su-Kyoung;Park, Sang-Ho;Kim, Kern-Joong;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1017-1024
    • /
    • 2017
  • The International Electrotechnical Commission(IEC) 61000-4-15 is a standard proposing techniques for a flicker meter test and measurement method. The IEC61000-4-15 ed1 announced in 1997 was not include tests for accurate verification. Also it was not explained flicker meter algorithm that can be directly applied to the other power systems. But the new edition of IEC61000-4-15 ed2 prescribes a variety of tests for verify flicker meter algorithm and it explains 'correction factor' used for measuring flicker in other power systems. It can measure flicker severity in 220V system by multiplying correction factor to the measured values with the 230V algorithm. This paper compared the method of measuring flicker severity in korea power system using the correction factor and the modified weighting filter, after verifying of digital flicker meter algorithm created by using matlab based on IEC61000-4-15 ed2.

A Study on the SAR Measurement System Validation at 150 MHz Band (150 MHz 대역에서의 SAR 측정시스템의 유효성 연구)

  • Choi, Donggeun;Kim, Kihwea;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.1008-1016
    • /
    • 2013
  • SAR measurement which was applied only to the mobile phone has been expanded in the Korean radio regulation law to the portable wireless communication equipments within 20 cm from the human body since Jan. 2012. The two-way radio operating at 150 MHz frequency band was newly included following the revised radio regulation in the target equipment of measurement. SAR measurement system at 150 MHz satisfying this regulation is necessary accordingly for SAR conformity assessment. The international SAR measurement standard(IEC 62209-2) includes the evaluation method on frequencies above 300 MHz, and the commercial SAR measurement system can measure SAR above 300 MHz only. The size of the reference dipole antenna(760 mm, return loss: -27.57 dB) and flat phantom ($1,300 mm(L){\times}900 mm(W){\times}200 mm(H)$), targeted SAR values for numerical analysis(1 g: 1.08 W/kg, 10 g: 0.77 W/kg) for SAR validation evaluation at 150 MHz frequency are proposed in this paper. The suggested dipole antenna and flat phantom are assembled and used to verify the conformity assessment of commercial SAR measurement system. The measured SAR values of 1 g and 10 g were obtained respectively to be 1.13 W/kg, 0.81 W/kg, and they satisfied the effective range(within ${\pm}10$ %) of IEC international standard. The standards based on this study are expected to be used for the domestic SAR measurement standard and IEC(International Electrotechnical Commission) international standard.

Implementation of a Jitter and Glitch Removing Circuit for UHF RFID System Based on ISO/IEC 18000-6C Standard (UHF대역 RFID 수신단(리더)의 지터(비트동기) 및 글리치 제거회로 설계)

  • Kim, Sang-Hoon;Lee, Yong-Joo;Sim, Jae-Hee;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1A
    • /
    • pp.83-90
    • /
    • 2007
  • In this paper, we propose an implementation and an algorithm of 'Jitter and Glitch Removing Circuit' for UHF RFID reader system based on ISO/IEC 18000-6C standard. We analyze the response of TI(Texas Instrument) Gen2 tag with a reader using the proposed algorithm. In ISO/IEC 18000-6C standard, a bit rate accuracy(tolerance) is up to +/-22% during tag-to-interrogator communication and +/-1% during interrogator-to-tag communication. In order to solve tolerance problems, we implement the Jitter and Glitch Removing Circuit using the concept of tolerance and tolerance-accumulation instead of PLL(DPLL, ADPLL). The main clock is 19.2MHz and the LF(Link Frequency) is determined as 40kHz to meet the local radio regulation in korea. As a result of simulations, the error-rate is zero within 15% tolerance of tag responses. And in the case of using the adaptive LF generation circuit, the error-rate varies from 0.000589 to zero between 15% and 22% tolerance of tag responses. In conclusion, the error-rate is zero between 0%-22% tolerance of tag response specified in ISO/IEC 18000-6C standard.

The Development of Interoperability Tester for the IEC 61850 based on TTCN-3 (TTCN-3 적합성 시험 언어를 이용한 IEC61850 상호 연동성 시험기 개발)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.210-218
    • /
    • 2010
  • TTCN-3(Testing & Test Control Notation Version 3) is the international standard testing language defined by ETSI in 2001. TTCN-3 is generally used for protocol conformance test, but it is also possible to be applied to the platform and API tests based on CORBA. Moreover, it can be also applied to the various testings such as interworking testing, repetition testing, platform testing, etc. IEC 61850 is the protocol proposed for SAS(Substation Automation System) of SCADA(Supervisory Control And Data Acquisition) system. In this paper, a IEC 61850 interoperability Tester based TTCN-3 is developed under the Window environment. IEC 61850 Server Simulator of Linux operating system is used as SUT(System Under Test). Conformance testing items in this paper are the Positive test case_Srv5 of "Server, Logical device, Logical node, and data model" in the testing group of "IEC 61850 - Part10" document.

Performance Analysis of Priority Scheme in the IEC/ISA Fieldbus (IEC/ISA 필드버스의 우선 순위 성능 분석)

  • Hong, Seung-Ho;Ko, Seong-Jun
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.94-117
    • /
    • 1998
  • This paper investigates the performance characteristics of the data link layer of the 1996 version of IEC/ISA fieldbus which is developed as internatioal standard of fieldbus. A discrete-event simulation model of the data link layer of IEC/ISA fieldbus is developed. Using the simulation model, this paper identifies the network parameters that influence the performance of prioritys scheme and real-time data transmission, and analyzes the delay performance of IEC/ISA fieldbus with respect to the change of network parameters. The simulation model also integrates continuous-time simulation model of a control system as application process. Using the integrated simulation model, this study investigates the effect of network-induced delay on the performance of control system. Since the simulation model developed in this study can predict the network performance, it will be effectively utilized in the design phase of control and automation systems that adopt the IEC/ISA fieldbus.

  • PDF

A Study on the Possibility of Transforming to Digital Substations using IEC 61850 Field Information Processing Panel of Legacy Substation (기존 변전소의 IEC 61850 기반 현장정보처리반을 이용한 디지털변전소 전환 가능성 검토에 관한 연구)

  • Yuk, Sim-Bok;Lee, Sung-Hwan;Kim, Chong-il
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.2
    • /
    • pp.129-136
    • /
    • 2018
  • The IEC 61850 communication standard is used worldwide, and within the country the new substation is built as a digital substation based on IEC 61850 from 2013, after field tests and R&D from 2007. Research on the development of digital substation operating system has been conducted mainly in large domestic companies, so the IED power application equipment for LCP are developed. However, there is still a lack of research in the field of systems that can accommodate all the field devices used for legacy substation and new digital substation. In this paper, we developed the 48VDC input modules and the 125VDC output modules which can construct proposed field information processing modules to IEC 61850 based type, and verified the field applicability from the state monitoring and control operation tests by using IEC 61850 client authentication program and Wireshark.

Analysis and Investigation of International(UIC, EN, IEC) and Domestic Standards(Test Methods) for Climatic Wind Tunnel Test of Rolling Stock (철도차량 기후환경시험을 위한 국제 규격(UIC, EN, IEC) 및 국내 규격(시험방법) 분석 및 고찰)

  • Jang, Yong-Jun;Chung, Jong-Duk;Lee, Jae-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.782-789
    • /
    • 2020
  • The demand for the development of rolling stock technology to maintain the best performance in various climatic environments has increased to expand the overseas market of rolling stock. In this study, international and domestic standards that must be applied to build a harsh climatic environment test system were investigated and compared. The way of improvement for domestic standards is proposed. The wind velocities and temperatures are specified in the UIC, EN, and IEC standards for climatic wind tunnel, and EN 50125-1 provides the velocity test up to 180km/h, the largest wind speed. UIC and EN provide the lowest temperature of -45℃, and IEC 62498-1 provides the highest temperature 55℃. The solar radiation test was specified up to 1200W/m2 in the UIC, EN, and IEC. The IEC, EN, and KS R 9145 provide the water tightness standards, which are different from each other in water capacity, pressure, and methods. The snow test method was not well specified. KRTS-VE-Part 31 provides pressurization test methods. The airtightness standards for high-speed rolling stock are defined and regulated for internal pressure change rate in UIC 660 and 779-11. The domestic standard for the wind tunnel test was not well prepared, and the solar radiation test and snow test do not exist in Korea. Therefore, it is necessary to improve domestic standards to an international level for the climatic wind tunnel test of rolling stock.

A Study on The Application of ISO/IEC 17025 Software Accredited Testing Institute Using ISO/IEC/IEEE 29119 and ISO/IEC 25023 (ISO/IEC/IEEE 29119와 ISO/IEC 25023을 이용한 ISO/IEC 17025 소프트웨어 공인시험기관 적용에 관한 연구)

  • Lee, Chang-Hee;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Kim, Myung-Sup;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.97-106
    • /
    • 2020
  • The purpose of this study is to determine how to apply ISO/IEC/IEEE 29119 software test procedures and ISO/IEC 25023 software test evaluation items to software-accredited testing laboratories based on the ISO/IEC 17025 international standard requirements. As a method, the overall requirements for their application to a test laboratory were analyzed by mapping ISO/IEC/IEEE 29119 and ISO/IEC 25023 based on ISO/IEC 17025. According to the mapping analysis, a total of 29 documents were created, including quality manuals, procedures, and test guidelines for the operation of the test laboratory. As a result of the study, a test laboratory management system was developed using Confluence 6.15 software by applying the analyzed results of the overall requirements. The test procedures, documents, and records were stored in, and operated from, this system. Verification of suitability for operation of the test laboratory was conducted by KOLAS evaluators through a document review and an on-site audit at the LG Electronics SW Accredited Test Laboratory in Seoul. In conclusion, it was confirmed through the KOLAS evaluation that the test laboratory management system and the operation of the test laboratory are appropriate and, compared with previous cases, the test laboratory operates effectively, and the overall schedule of accreditation could be shortened.