• 제목/요약/키워드: IEC 61400

검색결과 87건 처리시간 0.027초

3MW 풍력발전시스템 개발품의 육상풍력실증단지 조성 타당성 평가를 위한 풍황 및 지형평가 연구 (Wind Analysis and Site Assessment for Test Site of 3MW Wind Power System)

  • 우상우;이기학;이상일;박종포
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.35.2-35.2
    • /
    • 2011
  • A wind turbine power performance test is very important to wind turbine manufacturers because a wind farm developer or planner must want to define power performance characteristics and reliability of new wind turbines. Based on the IEC 61400-12-1, A wind turbine test site has to be nicely installed at flat terrain for testing. We are developing the wind power system which is IEC wind class IIa model with rated power of 3MW. KEPCO's Gochang power testing center was considered as candidates to build the test site without site calibration. This paper aims to verify the validity of the test site by using implement site assessment result that was based on IEC 61400-12-1.

  • PDF

풍력발전용 소형복합재 블레이드의 실규모 구조시험 (Full Scale Structural Testing of Small Wind Turbine Composite Blade)

  • 김홍관;김태성;이장호;문병영;강기원
    • 대한기계학회논문집A
    • /
    • 제35권11호
    • /
    • pp.1407-1413
    • /
    • 2011
  • 소형풍력발전시스템의 복합재 블레이드에 대한 실규모 구조시험 및 이를 모사한 구조해석을 통하여 설계 타당성을 검증하였다. 먼저 IEC 61400-2 에 규정된 설계 요구조건의 만족을 위하여 정격 풍속 및 IEC 61400-2 Case H 의 최악 조건에 대한 구조해석을 수행하고 이를 통하여 적층 순서 및 적층 두께를 결정하였다. 또한 이러한 구조해석의 타당성 검증을 위하여 IEC 61400-23 에 따라 구조해석과 동일한 하중조건에서의 실규모 구조시험을 실시하였다. 이러한 실규모 구조시험을 통한 구한 블레이드의 하중-변위 선도 및 표면의 변형률 특성을 이용하여 블레이드의 구조적 안전성을 평가하였다.

750kW급 DFIG 풍력 발전기 모니터링 시스템 개발 및 통신 표준화 적용 방안에 관한 연구 (750kW-class DFIG Wind Turbine Monitoring System Development and Study on Scheme for Applying Standardized Communication)

  • 이덕수;이준철;최인선;최영준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.327-330
    • /
    • 2008
  • This paper presents monitoring system for 750kW-class DFIG wind turbine generator system and an architecture for applying standardized communication, IEC61400-25. Monitoring and control system is consists of wind turbine PLC, Local and Remote I/O Server, HMI. and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test local and/or remote monitoring and control system and evaluate the performance of 750kW-class WTS. Finally we described the design of logical nodes and services based on IEC61400-25 and its application scheme.

  • PDF

풍력터빈 성능 검증을 위한 출력측정 유효영역 선정 (Selection of Available Sector to Measure Power Generation for Validation of Wind Turbine Performance)

  • 오기용;정훈;이준신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.525-528
    • /
    • 2009
  • Power generation of wind turbine which is installed in wind farm should be measured to predict economic feasibility of wind farm. Also electric power company want to verify wind turbine performance which is stated by manufacturer. The International Electrotechnical Commission(IEC) published 61400-12-1 "Power performance measurements of electricity producing wind turbines" for test of wind turbine power performance. In this paper, measurable sector of wind speed is analysed based on IEC 61400-12-1 to verify power curve of wind turbine with various wind turbine in wind farm.

  • PDF

이종 풍력 터빈의 감시 제어를 위한 통신 시스템 구조 (A New Structure of Communication System for Monitoring and Control of Heterogeneous Wind Tubines)

  • 김태형;황태호;함경선
    • 정보통신설비학회논문지
    • /
    • 제10권1호
    • /
    • pp.40-45
    • /
    • 2011
  • As increasing the importance of renewable energy recently, the scale of a wind power plant is increasing to the number of GW scale and specially, it is trend to move from onshore to offshore to use the higher quantity and quality of wind. Consequently to meet the trend, it is largely considered the importance of communication protocol to control and monitor remotely. But, because the communication protocol between the control center and a wind turbine has been independently developed by each wind turbine vendor, it is absence of the compatibility and extensibility when the heterogeneous wind turbines are installed in the wind farm. The IEC 61400-25 is the specifying standard for these problems in Europe. In this paper, we will show the state of these problems and present a new structure of communication based on the IEC 61400-25 to get the compatibility and extensibility between a control center and wind turbines.

  • PDF

Special cases in fatigue analysis of wind turbines

  • Gunes, Onur;Altunsu, Elif;Sari, Ali
    • Wind and Structures
    • /
    • 제32권5호
    • /
    • pp.501-508
    • /
    • 2021
  • The turbine industry demands a reliable design with affordable cost. As technological advances begin to support turbines of huge sizes, and the increasing importance of wind turbines from day to day make design safety conditions more important. Wind turbines are exposed to environmental conditions that can affect their installation, durability, and operation. International Electrotechnical Commission (IEC) 61400-1 design load cases consist of analyses involving wind turbine operating conditions. This design load cases (DLC) is important for determining fatigue loads (i.e., forces and moments) that occur as a result of expected conditions throughout the life of the machine. With the help of FAST (Fatigue, Aerodynamics, Structures, and Turbulence), an open source software, the NREL 5MW land base wind turbine model was used. IEC 61400-1 wind turbine design standard procedures assessed turbine behavior and fatigue damage to the tower base of dynamic loads in different design conditions. Real characteristic wind speed distribution and multi-directional effect specific to the site were taken into consideration. The effect of these conditions on the economic service life of the turbine has been studied.

IEC 61400-1 DLC1.1과 DLC1.3에 대한 풍력터빈의 극한하중 특성 (Characteristics of Ultimate Load in a Wind Turbine for IEC 61400-1 DLC1.1 and DLC1.3)

  • 김충옥;남현우;음학진;김귀식
    • 한국태양에너지학회 논문집
    • /
    • 제32권1호
    • /
    • pp.15-24
    • /
    • 2012
  • IEC 61400-1 requires design lifetime of wind turbines at least 20 years, thus wind turbine should be assured for structural safety through load assessment. DLCs have been defined with respect to the load assessment in IEC 61400-1. In addition, if the extreme design values for DLC1.3 are equal or exceed the extreme design value for DLC1.1, DLC1.1 may be omitted. To omit DLC1.1, scale factor (c) will be increased in DLC1.3. However, this particular adjustment is not specified guidelines. Thus, this study was conducted. DLC1.1 was calculated for extrapolation of 50 years-extreme events using several probability distribution functions and fitting methods. And DLC1.3 was calculated for up to seven different values of scale factor (c) with $2{\leq}c{\leq}5$ in steps of 0.5. Finally, in this study, scale factor (c) that was the value of 4.51 was determined.

Response Analysis of MW-Class Floating Offshore Wind Power System using International Standard IEC61400-3-2

  • Yu, Youngjae;Shin, Hyunkyoung
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.454-460
    • /
    • 2020
  • In 2019, the Korean government announced the 3rd Basic Plan for Energy, which included expanding the rate of renewable energy generation by 30-40% by 2040. Hence, offshore wind power generation, which is relatively easy to construct in large areas, should be considered. The East Sea coast of Korea is a sea area where the depth reaches 50 m, which is deeper than the west coast, even though it is only 2.5 km away from the coastline. Therefore, for offshore wind power projects on the East Sea coast, a floating offshore wind power should be considered instead of a fixed one. In this study, a response analysis was performed by applying the analytical conditions of IEC61400-3-2 for the design of floating offshore wind power generation systems. In the newly revised IEC61400-3-2 international standard, design load cases to be considered in floating offshore wind power systems are specified. The upper structure applied to the numerical analysis was a 5-MW-class wind generator developed by the National Renewable Energy Laboratory (NREL), and the marine environment conditions required for the analysis were based on the Ulsan Meteorological Buoy data from the Korea Meteorological Administration. The FAST v8 developed by NREL was used in the coupled analysis. From the simulation, the maximum response of the six degrees-of-freedom motion and the maximum load response of the joint part were compared. Additionally, redundancy was verified under abnormal conditions. The results indicate that the platform has a maximum displacement radius of approximately 40 m under an extreme sea state, and when one mooring line is broken, this distance increased to approximately 565 m. In conclusion, redundancy should be verified to determine the design of floating offshore wind farms or the arrangement of mooring systems.

계통연계 풍력발전기의 전력품질 평가를 위한 IEC 61400-21 표준 실시간 계측 장치 구현 (An Implementation of Real-time Measurement and Assessment System for Power Quality Characteristics of Grid Connected Wind Turbines)

  • 이종주;김동준;문영환
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1560-1565
    • /
    • 2010
  • The renewable resource are getting more attentions with increased concerns on the depletion of fossil fuels and several environmental issues like emission problem. Wind power is a representative option among several renewable sources and the generation capacity using wind power is being increased. However, the wind generation is so volatile on its output characteristic, so it is required to assess the grid impact of wind power generation by measuring the fluctuation effect more precisely. This paper proposes the method for measuring the generation output according to IEC 61400-21(Measurement and assessment of power quality characteristics of grid connected wind turbines) to assess the power quality of wind turbine generation. In addition, it shows an application case to a small-scale wind power generator. In the case study, it suggests a structure design of the proposed measurement instrument both on hardware and software aspects, which is composed of a remote monitoring & data analysis program and an FPGA based real-time signal processing device.