• Title/Summary/Keyword: IEC 61000-3-7

Search Result 14, Processing Time 0.037 seconds

Assessment and Management Method of Flicker Emission Level Based on IEC 61000-3-7 for Domestic Extra-high Voltage Customers (국내 특고압 고객에 대한 IEC 61000-3-7 기반의 플리커 방출한계 평가 및 관리 방안 연구)

  • Han, Su-Kyoung;Shin, Hoon-Chul;Park, Sang-Ho;Kim, Kern-Joong;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • IEC 61000-3-7 provides guidance for limiting flicker and enabling the connection of fluctuating load installations, that is, producing flicker in MV, HV and EHV power systems. In Korea, the flicker have been restricted by Japanese standard of ${\Delta}V_{10}$ method. ${\Delta}V_{10}$ was developed only for arc furnaces in 1960's. And now it is revealed that it is not suitable for application to other fluctuating load installations through many researches. $P_{st}$ which is a flicker index used in IEC 61000-3-7, indicates visual inconvenience due to voltage fluctuation across large range of frequency and can be applied to fluctuating load installations as well as arc furnaces. In this paper, we introduce how to calculate and assess flicker emission level for the individual fluctuating load installations connected in EHV system and how to manage the emission levels in the power system according to IEC 61000-3-7.

Analysis of Technology for RF Radiated E/H Fields EMS Tests (복사 전기장 및 자기장 내성시험 기술 분석)

  • Yum, J.H.;Choi, H.D.;Chae, J.S.
    • Electronics and Telecommunications Trends
    • /
    • v.17 no.4 s.76
    • /
    • pp.123-134
    • /
    • 2002
  • ISO/IEC14443-1(1), ISO/IEC10536-1(2), 그리고 ISO/IEC15693-1(3)에서 정의하고 있는 비접촉식 카드의 교류전기장 및 교류자기장에 대한 내성력 시험에 대해 살펴보고자 한다. 상기 규격은 ISO/IEC JTC1 기술위원회의 SC17에서 다루고 있으며, 아직 상기 표준 규격은 초안 상태에 있어 상세한 시험 방법에 대한 규격이 마련되어 있지 않은 실정이다. 그럼에도 불구하고 칩 카드 수입국은 수출업자에게 교류전기장 및 교류자기장 내성시험을 요구하고 있다. 따라서 업계에서는 시험 시설, 시험 방법, 시험 절차, 시험 평가 부분에서 많은 혼란이 발생되고 있다. 이러한 시험에 대한 대응책이 국가적 차원에서 시급히 마련되어야 할 것이다. 본 고에서는 이를 위한 일련의 과정으로서, 칩 카드 관련 국제 규격(1)-(5) 동향을 살펴보고, 교류전기장 및 교류자기장 내성력 시험 절차를 마련하기 위한 관점에서 IEC61000 시리즈 중에서 RF 복사 내성시험인 IEC61000-4-3(6), IEC61000-4-8, IEC61000-4-9, IEC61000-4-10, IEC61000-4-23(7)에 대한 분석을 동시에 실시하였다.

A Study on the Harmonic and Flicker Effects of SVC in Electric Arc Furnace Loads (전기로 부하에서 SVC의 고조파 및 플리커 효과에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bumb;Oh, Jung-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.150-158
    • /
    • 2007
  • Large steel industries have time-varying nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Flicker can be defined as the effect produced on the human visual perception by a changing emission of light lamps subjected to magnitude fluctuations of their supply voltage. The main objective of the static var compensator(SVC) is to maintain the rms voltage at the point of common coupling within the limit. In this paper, harmonic and flicker mitigation studies with and without the SVC are investigated and are evaluated by the IEC 61000-3-6 and IEC 61000-3-7.

A Study on the Harmonics and Flickers Measurement of High Speed Electric Train Loads (고속열차 부하의 고조파 및 플리커 측정에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.71-77
    • /
    • 2007
  • High speed electric trains have time-varying nonlinear loads causing voltage fluctuations to the power system. A cumulative probablistic approach is the most commonly used method to solve time varying loads. Flicker can be defined as the effect produced on the human visual perception by a changing emission of light lamps subjected to magnitude fluctuations of their supply voltage. This paper provides an in depth analysis on harmonics and flickers measurement of the high speed electric train loads. And the measurement results are evaluated by the IEC 61000-3-6 and IEC 61000-3-7.

A Study on Flicker Management Standard for Distribution Power System in Korea based on IEC 61000-3-7 (IEC 기반의 배전계통 플리커 관리기준 연구)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1663-1667
    • /
    • 2011
  • Voltage variation caused by large loads such as arc furnace and large motors, which use the large and instantaneous currents, can cause the voltage flicker. The flicker irritates the human's eyes and also has an adverse effect on protection device, rotating machine and electronic device etc, therefore the flicker needs to be managed effectively. Recently, the Korea power quality standard has been established on the IEC standards. This paper presents the flicker management standard for distribution power system and suggests the flicker transfer coefficients for Korea power system based on the IEC 61000-3-7.

Time-varying Harmonics Measurement and Assessment of the Electric Arc Furnace Loads (시간에 따라 변하는 전기로 부하의 고조파 측정 및 평가)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Park, Sang-Young;Lee, Joo-Hong;Lee, Il-Moo;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces and harmonic field measurements have shown that harmonic content of a waveform varies with time. Since the large loads are supplied from the power system grid, it must be recognized that not only will the system of utility be impacted, but neighboring customer system could be impacted as well. In this paper time-varying harmonics are evaluated by international harmonic standards IEEE Std. 519 and IEC 61000-3-6 using a cumulative probablistic approach.

A Study on the Harmonics Measurement and Assessment of the Electrolyzer Loads (전해조 부하의 고조파 측정 및 평가에 관한 연구)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Park, Sang-Young;Lee, Il-Moo;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.29-37
    • /
    • 2006
  • Heavy chemical industries have nonlinear loads including elecrolyzers. AC-DC converters are the most widely used in an elecrolysis in a chemical plant. The electrolysis consists of AC-DC converter groups connected in parallel at the DC side. The converter operations cause harmonic currents and create distortions on the sinusoidal voltage of the AC power system. This paper provides an in depth analysis on harmonics field measurement for the electrolyzer loads and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE 519-1992.

A Study on the Flicker Transfer Coefficient of IEC 61000-3-7 in Korea Power System (IEC 기반의 플리커 관리기준 수립을 위한 플리커 전달계수 산정 연구)

  • Kang, Moon-Ho;Lee, Beong-Sung;Choi, Won-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.995-996
    • /
    • 2011
  • 전압의 시간적 변동으로 인하여 시각적 혹은 심리적으로 인식되는 불편함을 나타내는 플리커는 인간의 생체심리학적 인지능력과 관련이 있으며, 인간의 눈은 0.3%에서 0.4%의 매우 작은 전압변동에 대하여 5Hz에서 20Hz의 변조 주파수에서 민감하게 반응하며, IEC는 실증시험을 통해 8.8Hz의 전압변동에서 가장 민감하게 인식하는 것을 확인하였다. 이러한 플리커는 시각적 불쾌감과 함께 지속적인 경우 회전기와 같은 기기들에 악영향을 주며, 전자장비, 전구, CRT 장비, UPS 동기상실, 제어설비 및 보호설비의 오동작 발생으로 효과적으로 관리가 필요하다. 현재 국내 전기품질 관리기준은 IEC 국제규격을 바탕으로 제 개정 작업이 진행되고 있어 본 논문에서는 IEC 61000-3-7 국제규격을 국내 적용을 위해 필요한 국내 전력계통의 플리커 전달계수를 제시하였다.

  • PDF

A Study on the Fliker Effect of SVC in Electric Arc Furnace Loads (전기로 부하에서 SVC의 플리커 효과에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Il-Moo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.48-53
    • /
    • 2006
  • An electric arc furnace being used in the steel industry is a time-varying non-linear load causing voltage fluctuations to the power system. Flicker can be defined as the effect produced on the human visual perception by a changing emission of light lamps subjected to magnitude fluctuations of their supply voltage. The level of flicker depends on the amplitude, frequency and duration of the voltage fluctuations. In this paper, the voltage fluctuation problem in an 154[kV] system due to the electric arc furnace loads is investigated and the analysis results of the static var compensator application for the voltage flicker mitigation are presented and evaluated by the IEC 61000-3-7.

Time-varying Harmonics Measurement and Evaluation of the High Speed Electric Train Loads (시간에 따라 변하는 고속철 부하의 고조파 측정 및 평가)

  • Jin, Seong-Eun;Kim, Kyung-Chul;Lee, Joo-Hong;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.29-37
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the control synchronous motors. Harmonics produced by these devices are large, but also have noticeable time varying characteristics. Since the large loads are supplied from the power system grid, it must be recognized that not only will the system of utility be impacted, but neighboring customer system could be impacted as well. In this paper time-varying harmonics for high speed electric train loads are measured and evaluated by international harmonic standards IEEE Std. 519 and IEC 61000-3-6 using a cumulative probablistic approach.