Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS) (동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구)

  • Song, Hye-Min;Kim, Byung-Joo;Jeong, Hyuk;Ahn, Seong-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.524-530
    • /
    • 2010
  • Chloramphenicol is one of the most effective antibiotics for treatment of food-producing animals for typhoid fever. However, it has been reported that it caused severe side effects such as aplastic anemia in human, therefore the use of chloramphenicol for food-producing animal is prohibited by European Union and other countries. In this study, the analytical method using isotope dilution liquid chromatography-mass spectrometry (ID-LC/MS) was established for accurate determination of chloramphenicol in meat. Chloramphenicol was extracted with ethylacetate from porcine and solid phase extraction cartridge was used for enhancing the recovery. The residue of chloramphenicol in porcine was analyzed using the liquid chromatography mass spectrometer (LC/MS) interfaced with electrospray ionization source. Analysis was performed in negative mode with selected reaction mornitoring mode at m/z 321${\rightarrow}$257 of $[M-H]^-$ ${\rightarrow}$ $[M-H-(HCOCl)]^-$ and m/z 326 ${\rightarrow}$ 262 channels for its isotope. The established method was tested using fortified samples at the level of 0.2 1, 10, $25\;{\mu}g$/kg and analytical results agreed with the gravimetrically fortified values within their uncertainties. This method was validated by analyzing a certified reference material, BCR 445, from IRMM (Institute for Reference Materials and Measurement). Our measurement values agreed with the certified value within their uncertainties. The uncertainty of our measured value was much lower than that the certified value from IRMM.

Development of Isotope Dilution LC-MS/MS Method for Accurate Determination of Arsenobetaine in Oyster Certified Reference Material

  • Lee, Woo Young;Yim, Yong-Hyeon;Hwang, Euijin;Lim, Youngran;Kim, Tae Kyu;Lee, Kyoung-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.821-827
    • /
    • 2014
  • An isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) method has been developed and applied to the determination of arsenobetaine (AsB, ${(CH_3)_3}^+AsCH_2COO^-$) from oyster candidate certified reference material (CRM). The exact matching isotope dilution approach was adopted for accurate determination of AsB using $^{13}C_2$-labeled AsB as an internal standard. Efficiencies of different AsB extraction methods were evaluated using a codfish reference material and a simple sonication method was selected as the method of choice for the certification of the oyster candidate CRM. The hydrophilic interaction liquid chromatography (HILIC) combined with electrospray ionization tandem mass spectrometry (ESI/MS/MS) in selected reaction monitoring (SRM) mode was optimized for adequate chromatographic retention and robust quantification of AsB from codfish and oyster samples. By analyzing 12 subsamples taken from each 12 bottles systematically selected from the whole oyster CRM batch, the certified value of AsB was determined as $6.60mg{\cdot}kg^{-1}{\pm}0.31mg{\cdot}kg^{-1}$ and it showed excellent between-bottle homogeneity of less than 0.42%, which is represented by relative standard deviation of 12 bottles from the CRM batch. The major source of uncertainty was the certified value of the AsB standard solution.

Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry (동위원소희석 액체크로마토그래피/질량분석법에 의한 혈청 내 콜레스테롤의 정량)

  • Shin, Hyesun;Lee, Hwashim;Lee, Gaeho
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.502-509
    • /
    • 2008
  • An ID LC/MS (isotope dilution liquid chromatography/mass spectrometry) was used as a primary method for the quantitative analysis of cholesterol in human serum. The separation of cholesterol was carried out by Thermo ODS hypersil $C^{18}$ column. The mobile phase was 100% methanol, and flow rate was $0.3m{\ell}/min$. Cholesterol and cholesterol-$3,4-13C_2$ were monitored at m/z 369.4 and 371.3, which correspond to $[M-H_2O+H]^+$ respectively. In order to verify the measurement method, NIST SRM 909b was analyzed. The results agreed well with certified values within uncertainty. The four kinds of serum certified reference material were prepared and certified. The repeatabilities of measurement were ranged from 0.1 to 0.8% (RSD), which were relatively good. The reproducibility between independent measurement run was below 0.24% (RSD). The expanded uncertainty was about 1.43% within the 95% confidence interval.

Quantitative analysis of cholesterol in infant formula by isotope dilution liquid chromatography-tandem mass spectrometry (동위원소희석 액체크로마토그래피 질량분석법에 의한 분유 내 콜레스테롤의 정량)

  • Ahn, Eun Jeong;Lee, Hwa Shim;Kim, Byung Joo;Lee, Gae Ho
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.460-466
    • /
    • 2015
  • An isotope dilution liquid chromatography tandem mass spectrometry was developed as a primary method for the quantitative analysis of cholesterol in infant formula. Cholesterol-d4 was used as an internal standard and spiked into the infant formula sample. In order to release cholesterol out of cholesteryl ester, which is cholesterol bound to fatty acids in infant formula, saponification was carried out. Saponification conditions were optimized with heating temperature, reaction time and the concentration of KOH. The optimum conditions were as follows; heating temperature was 70 ℃, reaction time was 180 min and the concentration of KOH was 0.8 mL of 8 M KOH for about 0.1 g infant formula sample. Extraction of cholesterol out of sample solution was carried out with hexane uisng liquid-liquid extraction. Chromatographic analysis was carried out using Phenomenex Kinetex C18 column. Mobile phase was 0.1% acetic acid in methanol/water (v/v, 99/1) and flow rate was 0.3 mL/min. Cholesterol and cholesterol-d4 were monitored at mass transfer m/z 369/259 and 373/263 respectively. Reproducibility of the method was evaluated to be 0.23% of the measurement result. The expanded uncertainty of the measurement result of cholesterol in infant formula was approximately 1.9% at a 95% confidence level. NIST standard reference material having certified values of cholesterol in infant formula, was analyzed in order to verify this method. The ID-LC/MS/MS results were well agreed with the certified values of NIST SRM within the uncertainty.

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

An analysis of benzoic acid, methyl paraben and butyl paraben in soy sauce using isotope dilution liquid chromatography mass spectrometry (동위원소희석 질량분석법을 이용한 간장 중의 안식향산, 메틸파라벤, 부틸파라벤의 분석)

  • Ahn, Seonghee
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.225-231
    • /
    • 2018
  • Benzoic acid, methyl paraben, and butyl paraben are preservatives that have been used in pharmaceutical, cosmetic, and food products. However, as their toxicities for human have been reported, many nations and organizations including Korea have established a regulation limit for thier usage of these preservatives in food products. The present study developed the isotope dilution liquid chromatography mass spectrometry method for accurate determination of three target preseratives in soysauce. In this study, the isotope dilution liquid chromatography mass spectrometry method was developed for accurate determination of three target preservatives in soy sauce. LC separation was optimized considering the pKa of benzoic acid which is lower than those of methyl and butyl parabens. A C18 column was used with 5 mM ammonium acetate and methanol as mobile phases. Mass spectrometry was operated in negative mode and selected reaction monitoring mode (SRM). Soy sauce sample was cleaned-up with C18 SPE cartridge for removing matrix inferences and color material. Optimized conditions and the method were validated with soy sauce reference materials for the analysis of food preservatives from Health Science Authority in Singapore. The measured values of benzoic acid, methyl and butyl paraben agreed well with reference values within their uncertainties.

Tandem Mass Spectrometric Analysis for Disorders in Amino, Organic and Fatty Acid Metabolism : 2 Years of SCL Experience in Korea

  • Yoon, Hye-Ran;Lee, Kyung Ryul
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.3 no.1
    • /
    • pp.86-93
    • /
    • 2003
  • Background : The SCL began screening of newborns and high risk group blood spots with tandem mass spectrometry (MS/MS) in April 2001. Our goal was to determine approximate prevalence of metabolic disorders, optimization of decision criteria for estimation of preventive effect with early diagnosis. This report describes the ongoing effort to identify more than 30 metabolic disorders by MS/MS in South Korea. Methods : Blood spot was collected from day 2 to 30 (mostly from day 2 to 10) after birth for newborn. Blood spot of high risk group was from the pediatric patients in NICU, developmental delay, mental retardation, strong family history of metabolic disorders. One punch (3.2 mm ID) of dried blood spots was extracted with $150{\mu}L$ of methanol containing isotopically labelled amino acids (AA) and acylcarnitines (AC) internal standards. Butanolic HCl was added and incubated at $65^{\circ}C$ for 15 min. The butylated extract was introduced into the inlet of MS/MS. Neutral loss of m/z 102 and parent ion mode of m/z 85 were set for the analyses of AA and AC, respectively. Diagnosis was confirmed by repeating acylcarnitine profile, urine organic acid and plasma amino acid analysis, direct enzyme assay, or molecular testing. Results : Approximately 31,000 neonates and children were screened and the estimated prevalence (newborn/high risk group), sensitivity, specificity and recall rate amounted to 1:2384/1:2066, 96.55%, 99.98%, and 0.73%, respectively. Confirmed 28 (0.09%) multiple metabolic disorders (newborn/high risk) were as follows; 13 amino acid disorders [classical PKU (3/4), BH4 deficient-hyperphenylalaninemia (0/1), Citrullinemia (1/0), Homocystinuria (0/2), Hypermethioninemia (0/1), Tyrosinemia (1/0)], 8 organic acidurias [Propionic aciduria (2/1), Methylmalonic aciduria (0/1), Isovaleric aciduria (1/1), 3-methylcrotonylglycineuria (1/0), Glutaric aciduria type1 (1/0)], 7 fatty acid oxidation disorders [LCHAD def. (2/2), Mitochondrial TFP def. (0/1), VLCAD def. (1/0), LC3KT def. (0/1). Conclnsion : The relatively normal development of 10 patients with metabolic disorders among newborns (except for the expired) demonstrates the usefulness of newborn screening by MS/MS for early diagnosis and medical intervention. However, close coordination between the MS/MS screening laboratory and the metabolic clinic/biochmical geneticists is needed to determine proper decision of screening parameters, confirmation diagnosis, follow-up scheme and additional tests.

  • PDF

Optimization of Microwave-Assisted Method for Accelerated Glycated Hemoglobin Quantification from Amino Acids to Proteins

  • Tran, Thi Thanh Huong;Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.53-58
    • /
    • 2017
  • Glycated hemoglobin ($HbA_{1c}$) has been commonly used to screen and diagnose for patients with diabetes mellitus. Here the accelerated procedure of microwave-assisted sample treatment from acid hydrolysis to enzyme digestion followed by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was optimized and applied to measure $HbA_{1c}$ in an effort to speed up analysis time. First, two signature peptides of $HbA_{1c}$ and hemoglobin $A_0$ were certified with amino acid analysis by setting optimized acid hydrolysis conditions to $150^{\circ}C$, 1.5 h and $10{\mu}M$ sample concentration in 8 M hydrochloric acid. Consequently, the accurate certified peptides above were used as calibration standards to implement the proteolytic procedure with endoproteinase Glu-C at $37^{\circ}C$, 700 W for 6 h. Compared to the traditional method, the microwave heating not only shortened dramatically sample preparation time, but also afforded comparable recovery yields. The optimized protocol and analytical conditions in this study are suitable for a primary reference method of $HbA_{1c}$ quantification with full SI-traceability and other similar proteins in complex biological samples.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.