• Title/Summary/Keyword: ICP0

Search Result 872, Processing Time 0.035 seconds

Electro-Optical Characteristics of an ICP Light Source Depending on Driving Temperature and Length of Discharge Tube (구동 온도와 방전관 길이에 따른 ICP 광원의 전기.광학적 특성)

  • Yim, Youn-Chan;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.107-113
    • /
    • 2008
  • We investigated the electro-optical characteristics of an ICP(Inductively Coupled Plasma) light source depending on driving temperature, and length of discharge tube. An electro-optical stability of a sample at operating was measured to see a steady state of a sample. In this results, we can see that a stability of power loss and luminous flux of a sample at operating of upper 70[min] was 1.45[%1 and 0.36[%]. We measured the optical characteristics of a sample in a thermal chamber operated at a specific temperature divided into 5 steps. While luminance increased with temperature increasing, the decrement of luminance a eared at u or $46.7[^{\circ}C]$. According to Parchen's and Boyle-Charles' law, we can speculate that a pressure was increased and a higher voltage was needed but a ballaster having a rating power can't support a higher voltage corresponding to a pressure change, 0.02[Torr] at $46.7[^{\circ}C]$. Moreover, we measured an a lied power and current of samples depending to a various length of a discharge tube.

Bioavailability of Tripotassium Dicitrato Bismuthate by ICP-MS in Human Volunteers (ICP-MS를 사용한 구연산비스마스칼륨 (Tripotassium dicitrato bismuthate)의 생체이용률 측정)

  • Kwon, Oh-Seung;Kwon, Jee-Young;Yoon, Ae-Rin;Park, Kyung-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.2
    • /
    • pp.79-84
    • /
    • 2007
  • This study was aimed to establish analytical method of Bi to develop a guideline of the bioequivalence test of tripotassium dicitrato bismuthate (TDB). For this purpose, a simple, specific and sensitive inductively coupled plasma-mass spectrometry (ICP/MS) method were developed and validated in human plasma. Various concentrations of bismuth standard solution (0-25ng/mL) were prepared with distilled water and human blank plasma. To 10mL of the volumetric flasks, 2mL of blank plasma was added with 8ml of distilled water. Bi standard solution was added to prepare the calibration samples and injected into ICP-MS. The plasma samples obtained from volunteers given 3 tablets of bismuth (total 900mg as TDB) were analyzed as described above. As a result, the coefficients of variation were <20% in quantitation limit (0.2 ng/mL) and <15% at the rest of concentrations. The stability test by repeated freezing-thawing cycles showed that the samples were stable only for 24hr. The stability tested for samples with a short-term period of storage at room temperature and pre-treatment prior to the analysis showed very stable over 24hr. In 8 healthy Korean subjects received Denol tablets at the dose of 900mg bismuth, AUC, $C_{max},\;T_{max}$ and half-life $(t_{1/2})$ were determined to be $198.33{\pm}173.78 ng{\cdot}hr/mL,\;64.48{\pm}27.06 ng/mL,\;0.52{\pm}0.21 hr,\;and\;5.15{\pm}2.67 hr$, respectively, from the plasma bismuth concentration-time curves. In conclusion, the method was suitable for the determination of bismuth in human plasma samples and could be applied to bioequivalence test of bismuth tablet.

A New On-line Coprecipitation Preconcentration Technique for Trace Metal Analysis by ICP-AES

  • Park, Gyeong Hui;Park, Yong Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.422-427
    • /
    • 1995
  • In a stream of water sample, trace metal ions are quantitatively coprecipitated with Indium hydroxide and filtered. The filtered precipitate is continuously dissolved in 3 M nitric acid and introduced to ICP directly. The lead, cadmium, and copper are concentrated more than 10-fold and determined with ICP-AES at a sampling frequency of 10/hour. The detection limits are 2.89, 1.43,0.52 ppb for lead, cadmium, and copper respectively. Recoveries of lead, cadmium, and copper are 98.7, 94.3, and 104.5% respectively. The RSD values for three elements are about 3-5% currently.

Postoperative Speech Outcomes and Complications in Submucous Cleft Palate Patients

  • Park, Tae Seo;Bae, Yong Chan;Nam, Su Bong;Kang, Kyung Dong;Sung, Ji Yoon
    • Archives of Plastic Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-257
    • /
    • 2016
  • Background The postoperative speech outcomes of submucous cleft palate (SMCP) surgery are known to be poorer than those of other types of cleft palate. We attempted to objectively characterize the postoperative complications and speech outcomes of the surgical treatment of SMCP through a comparison with the outcomes of incomplete cleft palate (ICP). Methods This study included 53 SMCP patients and 285 ICP patients who underwent surgical repair from 1998 to 2015. The average age of the patients at the time of surgery was $3.9{\pm}1.9years$ for the SMCP patients and $1.3{\pm}0.9years$ for the ICP patients. A retrospective analysis was performed of the complications, the frequency of subsequent surgical correction for velopharyngeal dysfunction (VPD), and speech outcomes. Results In both the SMCP and ICP patients, no cases of respiratory difficulty, bleeding, or wound disruption were noted. Delayed wound healing and fistula occurred in 18.9% and 5.7% of the SMCP patients and in 14% and 3.2% of the ICP patients, respectively. However, no statistically significant difference in either delayed wound healing or fistula occurrence was observed between the two groups. The rate of surgical correction for VPD in the SMCP group was higher than in the ICP group. In the subset of 26 SMCP patients and 62 ICP patients who underwent speech evaluation, the median speech score value was 58.8 in the SMCP group and 66 in the ICP group, which was a statistically significant difference. Conclusions SMCP and ICP were found to have similar complication rates, but SMCP had significantly worse speech outcomes.

Intracranial Pressure and Cerebral Blood Flow Monitoring after Bilateral Decompressive Craniectomy in Patients with Acute Massive Brain Swelling (급성 중증 뇌종창 환자의 양측성 감압개두술 후 뇌압 및 뇌혈류 측정)

  • Yoo, Do-Sung;Kim, Dal-Soo;Huh, Pil-Woo;Cho, Kyoung-Suck;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.295-306
    • /
    • 2001
  • Objectives : The management of massive brain swelling remains an unsolved problem in neurosurgical field. Despite newly developed medical and pharmacological therapy, the mortality and morbidity due to massive brain swelling remains high. According to many recent reports, surgical decompression with dura expansion is superior to medical management in patients with massive brain swelling. We performed surgical treatment on the first line of treatment, and followed medical management in case with refractory increased intracranial pressure(ICP). To show the quantitative effect of decompressive surgery on the intracranial pressure, we performed ventricular puncture and checked the ventricular ICP continuously during the decompressive surgery and postoperative period. Materials and Methods : Fifty-one patients with massive brain swelling, undergoing bilateral decompressive craniectomy with dura expansion, were studied in this study. In all patients, ventricular puncture was performed at Kocher's point on the opposite side of massive brain swelling. The ventricular pressure was monitored continuously, during the bilateral decompression procedures and postoperative period. Results : The initial ventricular ICP were varied from 13mmHg to 112mmHg. Immediately after the bilateral craniectomy, mean ventricular ICP decreased to $53.1{\pm}15.8%$ of the initial ICP(ranges from 5mmHg to 87mmHg). Dura opening decreased mean ICP by additional 36.7% and made the ventricular pressure $16.4{\pm}10.5%$ of the initial pressure (ranges from 0mmHg to 28mmHg). Postoperatively, ventricular pressure was lowered to $20.2{\pm}22.6%$(ranged from 0mmHg to 62.3mmHg) of the initial ICP. The ventricular ICP value during the first 24 hours after decompressive surgery was found to be an important prognostic factor. If ICP was over 35mmHg, the mortality was 100% instead of additional medical(barbiturate coma therapy and hypothermia) treatments. Conclusion : Bilateral decompression with dura expansion is considered an effective therapeutic modality in ICP control. To obtain favorable clinical outcome in patients with massive brain swelling, early decision making on surgical management and proper patient selection are mandatory.

  • PDF

Analytical Method of Silicon Dioxide in Health Functional Food Products using ICP-OES

  • Ka, Mi-Hyun;Lee, Kwang-Geun;Lim, Heung-Youl;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.343-347
    • /
    • 2017
  • The analytical method of silicon dioxide ($SiO_2$) in health functional food products was developed employing inductively coupled plasma optical emission spectrometry (ICP-OES) method assisted by acid (hydrofluoric acid and boric acid) digestion in open system without alkali fusion. The limit of detection (LOD) and limit of quantification (LOQ) of this method were found to be 0.07 and 0.20 mg/L, respectively. Linearity ($r^2$) and linear range were 0.99 and 0.20~20.0 mg/L, respectively. The accuracy and precision of $SiO_2$ (0.4, 1.0, and 2.0%, w/w) in spiked glucosamine exhibited to be the range of 90.22~94.14% and 0.72~1.67%, respectively. The contents of $SiO_2$ in 11 health functional food products were detected in range of 0.02~1.80% (w/w). Every sample showed below content of the permitted use level (2%, w/w) of $SiO_2$. Therefore ICP-OES method with acid can analyze the content of $SiO_2$ in health functional food products easily and rapidly. Consequently, the application of specification analysis of $SiO_2$ in health functional food products could be a significant work.

Low Temperature Deposition of ITO Thin Films for Flat Panel Displays by ICP Assisted DC Magnetron Sputtering (유도결합 플라즈마(ICP) Sputtering에 의한 평판 디스플레이(FPD)용 ITO 박막의 저온 증착)

  • 구범모;정승재;한영훈;이정중;주정훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.3
    • /
    • pp.146-151
    • /
    • 2004
  • Indium tin oxide (ITO) is widely used to make a transparent conducting film for various display devices and opto-electric devices. In this study, ITO films on glass substrate were fabricated by inductively coupled plasma (ICP) assisted dc magnetron sputtering. A two-turn rf coil was inserted in the process chamber between the substrate and magnetron for the generation of ICP. The substrates were not heated intentionally. Subsequent post-annealing treatment for as-deposited ITO films was not performed. Low-temperature deposition technique is required for ITO films to be used with heat sensitive plastic substrates, such as the polycarbonate and acrylic substrates used in LCD devices. The surface roughness of the ITO films is also an important feature in the application of OLEDs along with the use of a low temperature deposition technique. In order to obtain optimum ITO thin film properties at low temperature, the depositions were carried out at different condition in changing of Ar and $O_2$ gas mixtures, ICP power. The electrical, optical and structural properties of the deposited films were characterized by four-point probe, UV/VIS spectrophotometer, atomic force microscopy(AFM) and x-ray diffraction (XRD). The electrical resistivity of the films was -l0$^{-4}$ $\Omega$cm and the optical transmittance in the visible range was >85%. The surface roughness ( $R_{rms}$) was -20$\AA$.>.

Effect of the Brain Death on Hemodynamic Changes and Myocardial Damages in Canine Brain Death Model -Electrocard iographic and Hemodynamic Changes in the Brain Death Model Induced by Gradual Increase of Intracranial Pressure- (잡견을 이용한 실험적 뇌사모델에서 뇌사가 혈역학적 변화와 심근손상에 미치는 영향 -제2보 : 뇌압을 점진적으로 증가시켜 유발한 뇌사모델의 심전도 및 혈역학적 변화-)

  • 조명찬;이동운
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • We developed an experimental model of brain death using dogs. Brain death was induced by increasing the intracranial pressure (ICP) gradually by continuous Infusion of saline through an epidural Foley catheter in 5 mongrel dogs (weight, 18~22kg). Hemodynamic and electrocardiographic changes were evaluated continuously during the process of brain death and obtained the following results. 1. The average volume and time required to induce brain death was 4.8$\pm$1.0ml and 143.0$\pm$30.9minutes respectively. 2. There was a steady rise of the ICP after starting the constant infusion of saline, and ICP rised continuously until the brain death (122.0$\pm$62.5mmHg). After reaching to the maximal value (125.0$\pm$47.7mmHg) at 30 minutes after brain death, the ICP dropped and remained approximately constant at the slightly higher level than the mean arterial pressure (MAP). 3. MAP showed no change until the establishment of brain death and it declined gradually. The peak heart rate reached to 172.6$\pm$35.3/min at 30 minutes after the brain death. 4. Even though the body temperature and all hemodynamic variables, such as cardiac output, mean pulmonary arterial pressure, left ventricular (LV) end-diastolic pressure and LV maximum + dp/dt, were slightly greater than those of basal state, at the point of brain death, there was no statistically significant change during t e process of brain death. 5. There was no remarkable arrhythmias during the experiment except ventricular premature beats which was observed transiently in one dog at the time of brain death. Hemodynamic changes in the brain death model induced by gradual ICP increment were inconspicuous, and arrhythmias were rarely seen. Hyperdynamic state, which was observed at the point of brain death in another brain death model caused by abrupt ICP increase, was not observed.

  • PDF

Determination of Arsenic in Water by ICP-DRC/MS (ICP-DRC/MS를 이용한 수중의 비소 측정)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.620-625
    • /
    • 2006
  • In this investigation, an ICP-DRC/MS method to measure arsenic with ultra-trace concentration without any interference by the compounds such as $^{40}Ar^{35}Cl^+\;and\;^{40}Ca^{35}Cl^+$, which disturb the precise measurement of arsonic was described. Thus, the oxgen was introduced into the dynamic reaction cell as reaction gas and reacted with arsenic ion created in plasma gas, $AsO^+$ was formed and detected with m/z of 91 by ICP-MS. It resulted in better detection limit than the old method with m/z of 75($As^+$). The optimum condition for oxygen supply as the reaction gas was 0.5 mL/min. The analytical features of the method are as follows: detection limit of $0.02{\mu}g/L$, precision(RSD) of 3.4%, and recovery of 96%. Arsenic in the water samples from the tributary streams to the Han River and the main stream of Paldang were analyzed with this method to identify the characteristics in its distribution. The concentration of As ranged from 0.53 to $1.26{\mu}g/L$. We could measure As with very low concentration, less than $1.0{\mu}g/L$, with excellent reproducibility. The method developed is expected to be applied to analyze As of the samples from sea water, food, and domestic and industrial waste water which have high concentration of Cl and/or Ca.

A study on the Determination of Trace Se and Bi in the Scalp Hair by Hydride Generation- Inductively Coupled Plasma Atomic Emission Spectrometry (수소화물발생 유도결합플라즈마 원자방출분광법에 의한 머리카락 시료 중 미량의 Se와 Bi의 분석에 관한 연구)

  • Choi, Beom Suk;Lee, Dong Kee
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.26-34
    • /
    • 1996
  • A method to determine the trace amount of Se and Bi in the scalp hair using the hydride generation inductively coupled plasma atomic emmission spectrometry was studied. The optimum operation conditions of ICP for hydride generation are 0.6~0.8L/min for the carrier gas flow rate, and 6mm above the induction coil for the observation height. Hydrochloric acid concentrations for the optimum hydride generation conditions were greater than 1.5M when 2.5% $NaBH_4$ and NaOH were used, and greater than 0.5M when 2.5% $NaBH_4$ and 0.1% NaOH were used. Severe interference effects are observed from transition metals such as Cu and Ni, and they could be circumvented by the coprecipitation with lanthanum hydroxide.

  • PDF