• Title/Summary/Keyword: ICP spectroscopy

Search Result 306, Processing Time 0.028 seconds

A Diagnostic Study of Pulsed Plasma Process for Reactive Deposition (반응성 증착용 펄스 플라즈마 공정의 진단)

  • Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.4
    • /
    • pp.168-173
    • /
    • 2012
  • A real-time monitoring of an immersed antenna type inductively coupled plasma (ICP) was done with optical emission spectroscopy (OES) to check the reports that sputtered atom density is decreasing as the ICP power is increased. At 10 mTorr pressure of Ar, Mg was sputtered by a bipolar pulsed power supply into 2 MHz ICP which has an insulator covered 2.5 turn antenna. Emitted light was collected in two different positions: above the target and inside the ICP region. With 100 W of Mg sputtering power, the intensities of Mg I (285.06 nm), Mg II (279.48 nm), Ar I (420.1 nm) were increased constantly with ICP power from 100 W to 600 W. At 500 W, the intensity of $Mg^+$ exceeded that of Mg under PID controlled discharge voltage of 180 V. The ratio of Mg II/Mg I was increased from 0.45 to 2.71 approximately 6 times.

Tandem laser-induced breakdown spectroscopy laser-ablation inductively-coupled plasma mass spectrometry analysis of high-purity alumina powder

  • Lee, Yonghoon;Kim, Hyang
    • Analytical Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.121-130
    • /
    • 2019
  • Alumina is one of the most important ceramic materials because of its useful physical and chemical properties. Recently, high-purity alumina has been used in various industrial fields. This leads to increasing demand for reliable elemental analysis of impurities in alumina samples. However, the chemical inertness of alumina makes the sample preparation for conventional elemental analysis a tremendously difficult task. Herein, we demonstrated the feasibility of laser ablation for effective sampling of alumina powder. Laser ablation performs sampling rapidly without any chemical reagents and also allows simultaneous optical emission spectroscopy and mass spectrometry analyses. For six alumina samples including certified reference materials and commercial products, laser-induced breakdown spectroscopy (LIBS) and laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) analyses were performed simultaneously based on a common laser ablation sampling. LIBS was found to be useful to quantify alkali and alkaline earth metals with limits-of-detection (LODs) around 1 ppm. LA-ICP-MS could quantify transition metals such as Ti, Cu, Zn, and Zr with LODs in the range from a few tens to hundreds ppb.

Fabrication of Low Temperature Poly-Silicon by Inductively Coupled Plasma Assisted Magnetron Sputtering (유도결합 플라즈마-마그네트론 스퍼터링 방법을 이용한 저온 폴리실리콘 제조)

  • 유근철;박보환;주정훈;이정중
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.3
    • /
    • pp.164-168
    • /
    • 2004
  • Polycrystalline silicon thin films were deposited by inductively coupled plasma (ICP) assisted magnetron sputtering using a gas mixture of Ar and $H_2$ on a glass substrate at $250^{\circ}C$. At constant Ar mass flow rate of 10 sccm, the working pressure was changed between 10mTorr and 70mTorr with changing $H_2$ flow rate. The effects of RF power applied to ICP coil and $Ar/H_2$ gas mixing ratio on the properties of the deposited Si films were investigated. The crystallinity was evaluated by both X-ray diffraction and Raman spectroscopy. From the results of Raman spectroscopy, the crystallinity was improved as hydrogen mixing ratio was increased up to$ Ar/H_2$=10/16 sccm; the maximum crystalline fraction was 74% at this condition. When RF power applied to ICP coil was increased, the crystallinity was also increased around 78%. In order to investigate the surface roughness of the deposited films, Atomic Force Microscopy was used.

Cross-verified Measurement of Sulfide Concentration in Anaerobic Conditions Using Spectroscopic, Electrochemical, and Mass Spectrometric Methods

  • Nakkyu Chae;Samuel Park;Sungyeol Choi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.43-53
    • /
    • 2023
  • Sulfide concentrations critically affect worker safety and the integrities of underground facilities, such as deep geological repositories for spent nuclear fuel. Sulfide is highly sensitive to oxygen, which can oxidize sulfide to sulfate. This can hinder precise measurement of the sulfide concentration. Hence, a literature review was conducted, which revealed that two methods are commonly used: the methylene blue and sulfide ion-selective electrode (ISE) methods. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used for comparison with the two methods. The sulfide ISE method was found to be superior as it yielded results with a higher degree of accuracy and involved fewer procedures for quantification of the sulfide concentration in solution. ICP-OES results can be distorted significantly when sulfide is present in solution owing to the formation of H2S gas in the ICP-OES nebulizer. Therefore, the ICP-OES must be used with caution when quantifying underground water to prevent any distortion in the measured results. The results also suggest important measures to avoid problems when using ICP-OES for site selection. Furthermore, the sulfide ISE method is useful in determining sulfide concentrations in the field to predict the lifetime of disposal canisters of spent nuclear fuel in deep geological repositories and other industries.

Properties of the Pt Thin Etching in $BCI_3/CI_2$gas by Inductive Coupled Plasma (ICP에 의한 $BCI_3/CI_2$플라즈마 내에서 Pt 박막의 식각 특성)

  • 김창일;권광후
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.804-808
    • /
    • 1998
  • The inductively coupled plasma(ICP) etching of platinum with BCl$_3$/Cl$_2$ gas chemistry has been studied. X-ray photoelectron spectroscopy (XPS) was used to investigate the chemical binding states of the etched surface. The plasma characteristics was extracted from optical emission spectroscopy (OES) and a single Langmuir probe. In this case of Pt etching using BCl$_3$/Cl$_2$ gas chemistries, the result of OES and Langmuir probe showed the increase of Cl radicals and ion current densities in the plasmas with increasing Cl$_2$ gas ratio. At the same time, XPS results indicated that the intensities of Pt 4f decreased with increasing Cl$_2$ gas ratio. The decrease of Pt 4f intensities implies the increase of residue layer thickness on the etched Pt surface.

  • PDF

Structural and Field-emissive Properties of Carbon Nanotubes Produced by ICP-CVD: Effects of Substrate-Biasing (ICP-CVD 방법으로 성장된 탄소 나노튜브의 구조적 특성 및 전계방출 특성: 기판전압 인가 효과)

  • Park, C.K.;Kim, J.P.;Yun, S.J.;Park, J.S.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • Carbon nanotubes (CNTs) arc grown on Ni catalysts employing an inductively-coupled plasma chemical vapor deposition (ICP-CVD) method. The structural and field-emissive properties of the CNTs grown are characterized in terms of the substrate-bias applied. Characterization using the various techniques, such as field-omission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM), Auger spectroscopy (AES), and Raman spectroscopy, shows that the structural properties of the CNTs, including their physical dimensions and crystal qualities, as well as the nature of vertical growth, are strongly dependent upon the application of substrate bias during CNT growth. It is for the first time observed that the provailing growth mechanism of CNTs, which is either due to tip-driven growth or based-on-catalyst growth, may be influenced by substrate biasing. It is also seen that negatively substrate-biasing would promote the vertical-alignment of the CNTs grown, compared to positively substrate-biasing. However, the CNTs grown under the positively-biased condition display a higher electron-emission capability than those grown under the negatively-biased condition or without any bias applied.

Characteristics of Ni/SiC Schottky Diodes Grown by ICP-CVD

  • Gil, Tae-Hyun;Kim, Han-Soo;Kim, Yong-Sang
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.111-116
    • /
    • 2004
  • The Ni/SiC Schottky diode was fabricated with the $\alpha$-SiC thin film grown by the ICP-CVD method on a (111) Si wafer. $\alpha$-SiC film has been grown on a carbonized Si layer in which the Si surface was chemically converted to a very thin SiC layer achieved using an ICP-CVD method at $700^{\circ}C$. To reduce defects between the Si and $\alpha$-SiC, the surface of the Si wafer was slightly carbonized. The film characteristics of $\alpha$-SiC were investigated by employing TEM (Transmission Electron Microscopy) and FT-IR (Fourier Transform Infrared Spectroscopy). Sputterd Ni thin film was used as the anode metal. The boundary status of the Ni/SiC contact was investigated by AES (Auger Electron Spectroscopy) as a function of the annealing temperature. It is shown that the ohmic contact could be acquired beyond a 100$0^{\circ}C$ annealing temperature. The forward voltage drop at 100A/cm was I.0V. The breakdown voltage of the Ni/$\alpha$-SiC Schottky diode was 545 V, which is five times larger than the ideal breakdown voltage of the silicon device. As well, the dependence of barrier height on temperature was observed. The barrier height from C- V characteristics was higher than those from I-V.

Diagnosis of $BCl_3$ and $BCl_3$/Ar Plasmas with an Optical Emission Spectroscopy during High Density Planar Inductively Coupled Dry Etching (평판형 고밀도 유도결합 건식 식각시 Optical Emission Spectroscopy를 이용한 $BCl_3$$BCl_3$/Ar 플라즈마의 분석)

  • Cho, Guan-Sik;Wantae Lim;Inkyoo Baek;Seungryul Yoo;Park, Hojin;Lee, Jewon;Kuksan Cho;S. J. Pearton
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.88-88
    • /
    • 2003
  • Optical Emission Spectroscopy(OES) is a very important technology for real-time monitoring of plasma in a reactor during dry etching process. OES technology is non-invasive to the plasma process. It can be used to collect information on excitation and recombination between electrons and ions in the plasma. It also helps easily diagnose plasma intensity and monitor end-point during plasma etch processing. We studied high density planar inductively coupled BCl$_3$ and BCl$_3$/Ar plasma with an OES as a function of processing pressure, RIE chuck power, ICP source power and gas composition. The scan range of wavelength used was from 400 nm to 1000 nm. It was found that OES peak Intensity was a strong function of ICP source power and processing pressure, while it was almost independent on RIE chuck power in BCl$_3$-based planar ICP processes. It was also worthwhile to note that increase of processing pressure reduced negatively self-induced dc bias. The case was reverse for RIE chuck power. ICP power and gas composition hardly had influence on do bias. We will report OES results of high density planar inductively coupled BCl$_3$ and BCl$_3$/Ar Plasma in detail in this presentation.

  • PDF

Development and Round Robin Test of Pt-Co Alloy Thin Film Standard Materials for the Quantification of Surface Compositional Analysis (표면 조성분석의 정량화를 위한 Pt-Co 합금박막 표준시료의 개발 및 공동분석)

  • 김경중
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.176-186
    • /
    • 1998
  • Pure Pt, Co and their alloy thin films with three different compositions (Pt66-Co34, Pt40-Co60 and Pt18-Co82) were deposited on Si(100) wafers and proposed as a set of certified reference materials (CRM) for the quantification and standardization of surface compositional analysis. The compositions of the binary alloy thin films were controlled by in-situ XPS analyses and the certified compositions of the films have been determined by ICP-AES and RBS analyses after thin film growth. Through comparison of the compositions determined by in-situ XPS with those by ICP, relatively accurate compositions could be obtained with a matrix effect correction. Standard deviations of XPS and AES round robin tests with the Pt-Co alloy thin films were large up to about 4%. On the other hand, the average compositions of the Pt-Co alloy thin films by two methods were in a good agreement within 1%. The formation of a Pt rich surface layer by ion beam sputtering indicates that the surface modification by preferential sputtering must be understood for a better compositional analysis.

  • PDF

Analysis of Heavy Metal Concentration in Construction By-Products using Laser-Induced Breakdown Spectroscopy and Membrane Techniques (레이져 유도 플라즈마 분광법(LIBS)과 멤브레인을 활용한 건설용 부산물 내 중금속 분석에 관한 연구)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.113-121
    • /
    • 2023
  • In this study, the applicability and reproducibility of laser induced breakdown spectroscopy(LIBS) for heavy metal analysis in clinker and 5 types of by-products(crushed stone sludge, blast furnace slag, steel slag, waste concrete sludge, bottom ash) were experimentally reviewed. As a result of ICP-MS, XRF, and LIBS analysis of the six samples, the difference between ICP and XRF was confirmed in the quantitative analysis, but the LIBS analysis showed a difference by element from the standard analysis, and only qualitative analysis of the sample was possible. LIBS analysis wavelength was set for three types of heavy metals(Cd - 214.44nm, Pb - 405.78nm, Hg - 253.65nm). As a result of laser irradiation on the surface of the membrane impregnated with a solution of each concentration(1~1000ppm) and dried, the correlation between the spectral intensity and the concentration was confirmed.