• 제목/요약/키워드: ICC(Intraclass Correlation Coefficient)

검색결과 153건 처리시간 0.031초

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제12권4호
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF

스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구 (Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer)

  • 양회송;정찬주;유영대;배세현
    • 대한통합의학회지
    • /
    • 제4권2호
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.

Repeatability of the Measurement of Electrical Taste Detection Thresholds in Healthy Young Females

  • Hee Noh;Yeong-Gwan Im;Byung-Gook Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제48권4호
    • /
    • pp.144-151
    • /
    • 2023
  • Purpose: The aim of this study was to assess the repeatability of the electrical measurement of taste detection on different dates and in different sessions in healthy young females. Methods: The sites of electrical stimulation were the tip of the tongue, the posterolateral border of the tongue and the soft palate on the right side unilaterally. The measurements were repeated over three consecutive days, three sessions per day and three times for each session in seventeen healthy females. The repeatability of the measurement was assessed by the intraclass correlation coefficient (ICC). Results: In the dB unit, the ICC of the tip of the tongue and the soft palate was good (61.03 and 66.03, respectively); however, the lateral border of the tongue was a little lower (58.07). In the ㎂ unit, all three test sites had poor ICC. Variability was more significantly associated with the subject factor than with other factors such as trials, sessions and days in dB and ㎂ units. Conclusions: Electrogustometry, which measures electrical taste detection thresholds in the dB unit, is repeatable and acceptable for clinical use in assessing taste function in healthy young females.

Whiplash Disability Questionnaire의 한국어 번역 및 문화적 개작: 예비 연구 (Korean Translation, Cross Cultural Adaptation of Whiplash Disability Questionnaire: Pilot Study)

  • 이건영;조희근;김신애;박혜린;김은미;임혁빈;정준수
    • 한방재활의학과학회지
    • /
    • 제28권3호
    • /
    • pp.87-96
    • /
    • 2018
  • Objectives The purpose of this study is to provide more whiplash injury-specific measurement tools for Korean patients by measuring the validity and reliability of Korean version of Whiplash Disability Questionnaire (WDQ). Methods Bilingual clinicians translated the original WDQ into Korean. After consensus conference between researchers, it was back-translated into English. The pre-final version was completed and administered to 71 hospitalized patients diagnosed with whiplash injury. Validity was evaluated by concurrent validity. Reliability was assessed using Cronbach's ${\alpha}$ and intraclass correlation coefficient. Results The Korean WDQ showed good reliability with high internal consistency and intra-class correlation coefficient (Cronbach's ${\alpha}=0.96$, intraclass correlation coefficient [ICC]=0.82). Concurrent validity demonstrated positive correlations between Neck Disability Index, 36-Item Short Form Health Survey and WDQ. Conclusions The Korean version of WDQ is a valid and reliable tool for use as a measurement of whiplash injury in Korean patients, and it will be a very useful evaluation tool for both clinicians and researchers.

Assessment of a Questionnaire for Breast Cancer Case-Control Studies

  • Strumylaite, Loreta;Kregzdyte, Rima;Rugyte, Danguole Ceslava;Bogusevicius, Algirdas;Mechonosina, Kristina
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.2777-2782
    • /
    • 2013
  • The aim of the present study was to assess criterion validity and external reliability of a questionnaire on risk factors for breast cancer. Materials and Methods. Women with breast cancer diagnosis (the cases) (N=40) and matched individuals without cancer (the controls) (N=40) were asked to fill in a questionnaire twice: on a day of admission to hospital (Q1) and on a day before discharge (Q2), with a time interval of 4-6 days. The questionnaire included questions (N=150) on demographic and socioeconomic factors, diseases in the past, family history of cancer, woman's health, smoking, alcohol use, diet, physical activity, and work environment. Criterion validity of the questionnaire Q2 relative to reference questionnaire Q1 was assessed with the Spearman correlation coefficient (SCC); external reliability of the questionnaire was measured in terms of the intraclass correlation coefficient (ICC). Statistical analysis was performed with SPSS 16. Results. The responses to most of the questions on socioeconomic factors, family history on cancer, female health, lifestyle risk factors (smoking, alcohol use, physical activity) correlated substantially in both the cases and the controls with SCC and ICC>0.7 (p<0.01). Statistically non significant relationships defined only between the responses on amount of beer the cases drank at the ages up to 25 years and 26-35 years as well as time of use of estrogen and estrogens-progestin during menopause by the cases. Moderate and substantial SCC and ICC were determined for different food items. Only the response of the cases on veal consumption did not correlate significantly. Conclusions. The questionnaire on breast cancer risk factors is valid and reliable for most of the questions included.

Repeatability of a Multi-segment Foot Model with a 15-Marker Set in Normal Children

  • Kim, Eo Jin;Shin, Hyuk Soo;Lee, Jae Hee;Kyung, Min Gyu;Yoo, Hyo Jeong;Yoo, Won Joon;Lee, Dong Yeon
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.484-490
    • /
    • 2018
  • Background: The use of three-dimensional multi-segment foot models (3D MFMs) is increasing since they have superior ability to illustrate the effect of foot and ankle pathologies on intersegmental motion of the foot compared to single-segment foot model gait analysis. However, validation of the repeatability of the 3D MFMs is important for their clinical use. Although many MFMs have been validated in normal adults, research on MFM repeatability in children is lacking. The purpose of this study is to validate the intrasession, intersession, and interrater repeatability of an MFM with a 15-marker set (DuPont foot model) in healthy children. Methods: The study included 20 feet of 20 healthy children (10 boys and 10 girls). We divided the participants into two groups of 10 each. One group was tested by the same operator in each test (intersession analysis), while the other group was tested by a different operator in each test (interrater analysis). The multiple correlation coefficient (CMC) and intraclass correlation coefficient (ICC) were calculated to assess repeatability. The difference between the two sessions of each group was assessed at each time point of gait cycle. Results: The intrasession CMC and ICC values of all parameters showed excellent or very good repeatability. The intersession CMC of many parameters showed good or better repeatability. Interrater CMC and ICC values were generally lower for all parameters than intrasession and intersession. The mean gaps of all parameters were generally similar to those of the previous study. Conclusions: We demonstrated that 3D MFM using a 15-marker set had high intrasession, intersession, and interrater repeatability in the assessment of foot motion in healthy children but recommend some caution in interpreting the hindfoot parameters.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

Susceptance를 이용한 피부수화도 측정 장비의 개발 및 평가 (Development and Evaluation of skin Hydration Measure System using the Suscepance Method)

  • 김홍식;장우영;신건수;조백환;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.493-501
    • /
    • 2008
  • In this paper, a novel system is proposed to measure skin hydration using the susceptance method. This system largely consists of a low-voltage(${\pm}2.6$ V) driven circuit and minimized electrodes of size($5{\times}5mm^2$). To evaluate the accuracy of the novel system in measuring skin hydration, skin hydration values from 105 subjects are measured by the proposed system. The measurements are then compared to those obtained by the golden reference device based on the capacitance method in terms of Intraclass Correlation Coefficient(ICC) and correlation coefficient. All measurements are performed on 7 sites, which are forehead, Crow's foot, cheek, chin, volar forearm, dorsal forearm, and back of the hand, in a room where the temperature and humidity are maintained at an uniform level of $22{\pm}2^{\circ}C$ and $50{\pm}5%$, respectively. ICC values are above 0.9(p=0.001), signifying that the skin hydration values measured by the two methods show a good level of reliability. Correlation coefficient between the two methods is also 0.562(p=0.001). Based on these results, it is expected that the proposed system may be applicable in a variety of clinical or cosmetic areas.

뇌졸중 환자들의 한국판 Tinetti-보행 척도의 측정자간·절대적 신뢰도와 동시 타당도 (Inter-rater·absolute Reliability and Concurrent Validity of Tinetti-gait Scale (Korean version) in Stroke Patients)

  • 안승헌;이동건;이윤복;이규창
    • 대한물리의학회지
    • /
    • 제9권2호
    • /
    • pp.201-211
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the inter-rater absolute reliability and the concurrent validity of the Tinetti-gait scale that was translated into Korean for chronic stroke patients. METHODS: Fifty-two patients with post-stroke participated in this study. Inter-rater reliability was analyzed by Intraclass Correlation Coefficient ($ICC_{3,1}$) and Kappa coefficient, and absolute reliability was analyzed by the Standard Error of Measurement (SEM), and the Minimal Detectable Change (MDC). Concurrent validity was analyzed by correlating between the Tinetti-gait scale and physical functions. The physical functions were measured by using the Dynamic Gait Index(DGI), 10m walking test(10WT), One Leg Standing Test of affected/non-affected side(OLST), Sit to Stand test(STS), (Fugl Meyer assessment of Lower Extremity(FM-LE). RESULTS: The inter-rater reliability of the Tinetti-gait scale was high; $ICC_{(3,1)}=.91$ (95% CI=.85~.95) (very reliable), the range of Kappa coefficient were .73~.92 (substantial~good). The inter-rater agreement of the each item in Tinetti-gait scale ranged from .74 to .92 (95 % CI=.59~.95) (reliable~very reliable). The SEM and MDC were .56 and 1.55, respectively. In the results of concurrent validity, there were moderate positive correlation between Tinetti-gait scale and DGI (r=.78), 10WT (r=.74), OLST (r=.65~.73), FM-LE (r=67). And there was moderate negative correlation between Tinetti-gait scale and STS (r=-79) (p<.01). CONCLUSION: The Tinetti-gait scale(Korean version) was a reliable and valid tool to measure gait ability in patients with chronic stroke. Thus, it could be a useful tool for examining a gait ability of post-stroke patients. Further study should be conducted to investigate the usability to predict fall risk of post-stroke patients of the Tinetti-gait scale.

무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도 (Reliability and Validity of the Manual Measurement Method for Patellar Height)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.