• 제목/요약/키워드: IAQ

검색결과 260건 처리시간 0.022초

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

대학 도서관 건물 리모델링에 따른 실내공기질 영향 평가 (Impact Assessment of Remodeling Works on Indoor Air Quality in a University Library Building)

  • 백성옥;박대진;박선영;이여진
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.876-887
    • /
    • 2006
  • Recently, there have been a large number of remodeling (or renovation) works in old buildings in urban areas. Compared to new buildings, environmental risk might be more significant in such buildings where remodeling works are going on, since some parts of the building may still be in service for people. This study was carried out to investigate the impacts of remodeling works on the indoor air quality (IAQ) of a large building (a 22 stories university library). Indoor air monitoring was conducted during and after the remodeling works every two weeks for a one year period, and target compounds included BTEX, styrene, TVOC, carbonyl compounds such as formaldehyde and acetaldehyde. $CO,\;CO_2,\;PM_{10}$, and $PM_{2.5}$. Overall, the IAQ appeared to be recovered within two months after the remodeling works. However, in some places, concentrations of formaldehyde, toluene, xylene. and ethylbenzene showed higher levels even after works than those during the works. The results indicate that painting, glues and office furnitures are major sources of aromatic VOCs and formaldehyde. Therefore, in order to decrease the concentrations of toxic VOCs, the use of environmental-friendly building materials is strongly recommended during the remodeling works. In addition, IAQ control and management scheme (for example, baking the inside of the building) should be taken into consideration before reopening the buildings.

신축목조주택의 실내공기질 특성 및 관련요인 분석 (Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses)

  • 최윤정;이재경;차예랑
    • 한국주거학회논문집
    • /
    • 제26권4호
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

실내환경중의 산소발생기 사용에 대한 인식도 평가 (Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment)

  • 손종렬;조윤수;이규현;황상용
    • 환경위생공학
    • /
    • 제18권4호
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가 (IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function)

  • 이정재;이중훈;이승민
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

A Review of Scientific Evidence on Indoor Air of School Building: Pollutants, Sources, Health Effects and Management

  • Chithra, V.S;Shiva, Nagendra S.M
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권2호
    • /
    • pp.87-108
    • /
    • 2018
  • Schools are one of the critical social infrastructures in a society, the first place for social activity and the most important indoor environment for children besides the home. Poor IAQ in classrooms can increase the chance of long-term and short-term health problems for students and staffs; affects productivity of teachers; and degrade the student learning environment and comfort levels. The primary objective of this paper is to review and summarize available scientific evidence on indoor air quality of schools and related health effects in children. It was found that the indoor air pollutant levels in school buildings varied over a wide range in different parts of the world depending on site characteristics, climatic conditions, outdoor pollution levels, occupant activities, ventilation type and building practices. Among the indoor air pollutants, particulate matter concentrations were found to be very high in many schools. Outdoor pollutant sources also play a major role in affecting the IAQ of the school building. Hence, scientific knowledge on sources of indoor pollutants, quantification of emissions, temporal and spatial dispersion of pollutants, toxicological properties, chemical and morphological characteristics of the pollutants and associated health risk among children in the school buildings are essential to evaluate the adequacy and cost effectiveness of control strategies for mitigating the IAQ issues.

엘리베이터 실내공기질의 특성 기초조사 (A Study on the Characteristics of Indoor Air Quality in Elevator)

  • 박정호;추연규;서정민
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.

대학교 신축기숙사의 휘발성유기화합물 농도 및 새집증후군 반응 (The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory)

  • 최윤정;김정재;장윤정;오예슬
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.255-260
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor air quality by TVOC concentration and residents' responses and to analyze the influencing factors of IAQ in newly built university dormitory. The field measurements on the levels of TVOC and HCHO were carried out three times at an interval of 4 weeks in 3 rooms of a dormitory. The questionnaire survey on the residents that inquired into the lifestyle, the consciousness related to IAQ, and the responses of SHS was fulfilled. According to the results, the level of TVOC was approximately $0.14{\sim}18.5ppm$ and HCHO was $0.23{\sim}6.89ppm$ during 3 month since construction completion, which are seriously in excess of standard level, and seemed to be on the decrease as time goes by. The factors influencing the differences of the levels of TVOC or HCHO were the amount of ventilation including infiltration, heating temperature, relative humidity, or the use of living things including chemical. However, the residents rarely felt the responses of SHS and did not be conscious of the importance of ventilation.

  • PDF

Economizer cycle을 채용한 전열교환형 환기시스템의 에너지 절감 효과 분석 -국내 학교를 대상으로- (Energy Saving Effect of ERV(Energy Recovery Ventilator) with Economizer Cycle - Focused on the School Buildings -)

  • 김주욱;박재형;송두삼;주의성;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.695-700
    • /
    • 2009
  • Maintaining an IAQ with fresh in school building is very important because the good IAQ can be possible to improve the academic performance. Since school buildings are very dense and require a lot of fresh air, the need for ERV(Energy Recovery Ventilator) has become obvious. While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency. ERV technology offers an optimal solution: fresh air, better climate control and energy efficiency. However, when the outdoor air condition is favorable to control the indoor environment such as spring and autum in Korea, heat exchange in ERV would rather increase the cooling load than diminish. Economizer cycle control which using the outdoor air in controlling the indoor thermal environment has many benefit in terms of energy saving and IAQ control. In this study, the ERV with economizer cycle control will be suggested. And then the system control characteristics and energy saving effect will be analyzed through the TRSNSYS Simulation.

  • PDF

VAV 터미널 박스의 최소풍량 제어방식 비교 연구 (A Study on the Comparison Analysis of Minimum Airflow Control Logic of VAV Terminal Box)

  • 조영흠;강수현;성윤복
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.96-102
    • /
    • 2012
  • The minimum airflow of VAV terminal boxes is a key factor for comfort, indoor air quality(IAQ) and energy cost. If the minimum airflow is not reasonable, it would waste energy and make IAQ problems. There are two types of VAV terminal box control logic. One is the single maximum, another is the dual maximum control logic. Dual maximum control logic is more efficiency way to reduce the energy consumption. It has a minimum airflow set point and a heating maximum set point. It allows the minimum airflow set point to be much lower than single maximum control logic. A building simulation was conducted to evaluate the energy consumption and the IAQ according to the control logic of the V AV terminal box. In the simulation, dual maximum control logic can save the energy up to 6.5% compared to the single maximum control logic.