Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

$^{99m}Tc-MAG_3$ Elimination Index on Normal Functioning Transplanted Kidney ($^{99m}Tc-MAG_3$ 제거지수를 이용한 이식신장의 기능평가)

  • Jeon, Woo-Jin;Kim, Ju-Heon;Park, Mi-Ok;Lee, Hee-Jung;Hyun, Jung-Ae;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.79-83
    • /
    • 1995
  • Purpose : We analysed $^{99m}Tc-MAG_3$ renal scans to evaluate renal function of transplanted kidney and to detect various renal transplant complications, measuring the ratio of renal radioactivity at three minutes to that at 20 minutes(elimination index). Material and Methods : The fifty seven renal transplantation recipients were studied. There were 50 normal functioning transplanted kidneys as group I and 7 abnormal function-ing transplanted kidney, including 5 cases of acute renal rejection, 2 cases of acute tubular necrosis as group IIl. The protocol consisted of: (1) $^{99m}Tc-MAG_3$ 740MBq injection intravenously : (2) sequential imaging for 2min(60two-second images) followed by 30min(30 sixty-second images) : (3) drawing of region of interest(ROI) on renal imaging; (4) time-activity corves were generated from renal ROI after background subtraction, and time of maximum activity($T_{max}$) and half time of maximal peak radioactivity($T_{1/2}$) were produced in the renogram curve. (5) EI through Bischof-Delaloye method as determined on the renogram curve. Results : Normal group( I ) shows mean EI of 2.21(95.0% Confidence limit of 2.01-2.87), $T_{max}$ of 154 sec, $T_{1/2}$ of 1,139 sec. Abnormal group(II) shows mean EI of 0.74, $T_{max}$ of 1,466 sec, $T_{1/2}$ of 19,224 sec. The EI, $T_{max}$, $T_{1/2}$, BUN and serum creatinine values are significantly different between normal group(I) and abnormal group(II) (p<0.0001). Conclusion : By measuring EI with $^{99m}Tc-MAG_3$, renal function of transplanted kidney could be easily evaluated and various complications could be detected early.

  • PDF

Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene (FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형)

  • Yang, Sungmin;Choi, Hyo Won;Kang, Yun Koo;Lee, Jin-Sung;Namgoong, Mee Kyung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.20 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • A 22-month-old girl who had taken iron supplements due to iron deficiency anemia, presented bloody mucoid stool for one month. She had a bruise at the right periorbital area due to minor trauma and hepatosplenomegaly. Laboratory studies showed anemia, thrombocytopenia, elevated alkaline phosphatase (ALP), hypophosphatemia, decreased haptoglobin, hypocomplementemia, negative direct/indirect Coomb's test, normal vitamin D3 level and high PTHi. Wrist x-ray showed no signs of rickets. The abdominal ultrasound showed only accessory spleen. Tandem mass spectrometry was normal. During follow up, bloody stool regressed after seven days of withdrawal of iron supplement and cow milk, and the total CO2 level had been within 15-20 mEq/L with normal anion gap. NGS (next generation sequencing) panel test for evaluation of renal tubular acidosis showed negative results. After low dose steroid and vitamin D supplements under the impression of hypocomplementemic vasculitis, thrombocytopenia, C3/C4, decreased haptoglobin, and elevated ALP level became normal. At 57 months of age, laboratory findings showed elevated liver enzyme, ALP and gamma-glutamyl transferase again. And liver cirrhosis with splenomegaly and diffuse renal disease were reported with abdomen CT scan. Liver biopsy reported macro- and micronodular cirrhosis. Urine organic acid profile showed elevated succinylacetone level. Whole exome sequencing revealed novel compound heterozygous mutations (NM_00137.2:c.107T>C, NM_00137, 2:c.614T>C) in FAH gene and confirmed by Sanger sequencing. Consequently, the patient was diagnosed as chronic hereditary tyrosinemia type I. She started low phenylalanine/tyrosine diet and nitisinone treatment. Our case had presented symptoms very slowly, which is the first case of chronic tyrosinemia type I in South Korea.

Efficient Mining of Frequent Itemsets in a Sparse Data Set (희소 데이터 집합에서 효율적인 빈발 항목집합 탐사 기법)

  • Park In-Chang;Chang Joong-Hyuk;Lee Won-Suk
    • The KIPS Transactions:PartD
    • /
    • v.12D no.6 s.102
    • /
    • pp.817-828
    • /
    • 2005
  • The main research problems in a mining frequent itemsets are reducing memory usage and processing time of the mining process, and most of the previous algorithms for finding frequent itemsets are based on an Apriori-property, and they are multi-scan algorithms. Moreover, their processing time are greatly increased as the length of a maximal frequent itemset. To overcome this drawback, another approaches had been actively proposed in previous researches to reduce the processing time. However, they are not efficient on a sparse .data set This paper proposed an efficient mining algorithm for finding frequent itemsets. A novel tree structure, called an $L_2$-tree, was proposed int, and an efficient mining algorithm of frequent itemsets using $L_2$-tree, called an $L_2$-traverse algorithm was also proposed. An $L_2$-tree is constructed from $L_2$, i.e., a set of frequent itemsets of size 2, and an $L_2$-traverse algorithm can find its mining result in a short time by traversing the $L_2$-tree once. To reduce the processing more, this paper also proposed an optimized algorithm $C_3$-traverse, which removes previously an itemset in $L_2$ not to be a frequent itemsets of size 3. Through various experiments, it was verified that the proposed algorithms were efficient in a sparse data set.

QTL Scan for Meat Quality Traits Using High-density SNP Chip Analysis in Cross between Korean Native Pig and Yorkshire

  • Kim, S.W.;Li, X.P.;Lee, Y.M.;Choi, Y.I.;Cho, B.W.;Choi, B.H.;Kim, T.H.;Kim, J.J.;Kim, Kwan-Suk
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.9
    • /
    • pp.1184-1191
    • /
    • 2011
  • We attempted to generate a linkage map using Illumina Porcine 60K SNP Beadchip genotypes of the $F_2$ offspring from Korean native pig (KNP) crossed with Yorkshire (YS) pig, and to identify quantitative trait loci (QTL) using the line-cross model. Among the genotype information of the 62,136 SNPs obtained from the high-density SNP analysis, 45,308 SNPs were used to select informative markers with allelic frequencies >0.7 between the KNP (n = 16) and YS (n = 8) F0 animals. Of the selected SNP markers, a final set of 500 SNPs with polymorphic information contents (PIC) values of >0.300 in the $F_2$ groups (n = 252) was used for detection of thirty meat quality-related QTL on chromosomes at the 5% significance level and 10 QTL at the 1% significance level. The QTL for crude protein were detected on SSC2, SSC3, SSC6, SSC9 and SSC12; for intramuscular fat and marbling on SSC2, SSC8, SSC12, SSC14 and SSC18; meat color measurements on SSC1, SSC3, SSC4, SSC5, SSC6, SSC10, SSC11, SSC12, SSC16 and SSC18; water content related measurements in pork were detected on SSC4, SSC6, SSC7, SSC10, SSC12 and SSC14. Additional QTL of pork quality traits such as texture, tenderness and pH were detected on SSC6, SSC12, SSC13 and SSC16. The most important chromosomal region of superior pork quality in KNP compared to YS was identified on SSC12. Our results demonstrated that a QTL linkage map of the $F_2$ design in the pig breed can be generated with a selected data set of high density SNP genotypes. The QTL regions detected in this study will provide useful information for identifying genetic factors related to better pork quality in KNP.

Characteristics of Nasal Trauma in the Implanted Nasal Prosthesis (실리콘 코높임술 후 코 부위 외상의 특징)

  • Choi, Seok Min;Choi, Hwan Jun;Kim, Cheol Hann;Ahn, Hyung Sik;Kang, Sang Gue;Jung, Sung Gyun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.597-602
    • /
    • 2008
  • Purpose: Presently, silicone rubber is chosen most frequently for nasal augmentation. However, there is a possibility of extrusion with this material. Sometimes, noses are prone to be traumatized, and then silicone rubber has a possibility of deformity or deviation resulting in trauma. We experienced cases with complications and traumatic deformities after the augmentation rhinoplasty. Methods: A retrospective review was performed to determine the characteristics of the implanted nasal silicone prosthesis after trauma. The patients' data such as deviation of implant, shape of fracture, age and sex of the patient, time of treatment, operative methods were reviewed. From March 2001 to March 2008, this study was performed in 30 patients. The patients were 25 females and 5 males, from 24 to 60 years of age, with an average of 42. All patients had previous augmentation rhinoplasty with silicone implant. Results: All of the 30 patients were confirmed as deviation of silicone and nasal bone fractures in the facial bone CT scan. The most common cause of fracture was traffic accident. The classification of nasal trauma after augmentation was done by facial bone CT. Class I: Deviation of silicone without nasal bone fracture without extrusion(12 cases, 40%), Class II: Deviation of silicone without nasal bone fracture and with extrusion(4 cases, 13%), Class III: Deviation of silicone with nasal bone fracture and without extrusion(8 cases, 27%), Class IV: Deviation of silicone with nasal bone fracture and with extrusion(3 cases, 10%), Class V: Mild deviation of silicone with nasal bone fracture(3cases, 3%). Specially, the comminuted or trapezoid nasal fracture was confirmed in 11 cases(Class III, IV). Conclusion: The problems of silicone implant have generally been related to foreign body reactions, rigidity of the material, encapsulation, infections, and extrusion. We experienced 11 cases of comminuted or comminuted trapezoid shaped fracture below nasal implant. So, we think this phenomenon could be used in late problem of silicone implant.

Charge-discharge Characteristics of $LiCoO_2/Li$ Rechargeable Cell ($LiCoO_2/Li$ 2차전지의 충방전 특성)

  • Moon, S.I.;Doh, C.H.;Jeong, E.D.;Kim, B.S.;Park, D.W.;Yun, M.S.;Yeom, D.H.;Jeong, M.Y.;Park, C.J.;Yun, S.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.79-84
    • /
    • 1993
  • This paper describes the development of lithium rechargeable cell. $LiCoO_2$ is recently recognized as a suitable cathode active material of a high voltage, high energy lithium rechargeable batteries because $Li^+$ ion can be electrochemically deintercalated/intercalated from/to $Li_xCoO_2$. The transition metal oxide of $LiCoO_2$ was investigated for using as a cathode active material of 4V class Li rechargeable cell. $LiCoO_2$ cathode was prepared by using a active material of 85 wt%, graphite powder of 12 wt% as a conductor and poly-vinylidene fluoride of 3 wt% as a binder. The electrochemical and charge/discharge properties of $LiCoO_2$ were investigated by cyclic voltammetry and galvanostatic charge/discharge. The open circuit voltage of prepared $LiCoO_2$ electrode exhibited approximately. potential range between 3.32V and 3.42V. During the galvanostatic charge/discharge, $LiCoO_2/Li$ cell showed stable cycling behavior at scan rate of 1mV/sec and potential range between 3.6V and 4.2V. Also its coulombic efficiency as function of cycling was 81%~102%. In this study the $LiCoO_2/Li$ cell showed the available discharge capacity of 90.1 mAh/g at current density of $1mA/cm^2$ and cell discharge voltage range between 3.6V~4.2V.

  • PDF

Effect of occlusal balance on center of gravity in body (교합균형이 자세 중심(重心)에 미치는 영향에 관한 연구)

  • Lee, Yun;Choi, Dae-Kyun;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.57-67
    • /
    • 2003
  • Suppose that dental occlusion is related to body posture. We want to find out that improving occlusal balance may affect vibration and distribution of C.O.P. in which way, by measuring change of posture and center of gravity (center of pressure, C.O.P.) which plays important role in measuring balance sensation. Total 11 students at Kyung Hee dental college students, 4 females and 9 males (age: 23-30) participated in this test, who have normal occlusion (Angle's classification I), no TMJ problems. All of the participants have no tooth loss except 3rd molar, no prosthesis over single tooth restoration, no orthopedic problems which affect balance sensation, and no otorhinolaryngological problems. First, we registrated bite by centric relation, and then fabricated stabilization splint that is increased 3.5mm vertical dimension around premolar region. By F-scan (Tekscan Inc., Boston, Mass), we measured discrepancy of average contact pressure of left and right foot. And we also measured discrepancy of vibration of C.O.P(center of pressure). before setting stabilization splint and after wearing stabilization splint at intervals of 1 week, 2 weeks, 3 weeks after. In normal human beings, improved occlusal balance by stabilization splint leads to decrease of vibration of C.O.P. (P<0.05). One week after wearing stabilization splint, vibration of C.O.P. decreased reliably (P<0.05), two weeks after wearing stabilization splint, vibration of C.O.P. decreased similarly comparing to before wearing and one week after wearing. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. (P>0.05) Difference between average contact pressure of right and left foot also decreased. (P<0.05) We could find decrease after one week of wearing stabilization splint (P<0.05) and two weeks after, the decrease was more reliable than one week after. (P<0.05) After two weeks and three weeks, however, it was hard to find reliability. Improvement of occlusal balance leads to decrease of vibration of C.O.P. and decrease of difference between right and left average contact pressure.

Comparable Ablation Efficiency of 30 and 100 mCi of I-131 for Low to Intermediate Risk Thyroid Cancers Using Triple Negative Criteria

  • Fatima, Nosheen;Zaman, Maseeh uz;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1115-1118
    • /
    • 2016
  • Background: There is controversy about ablation efficacy of low or high doses of radioiodine-131 (RAI) in patients with differentiated thyroid cancers (DTC). The purpose of this prospective study was to determine efficacy of 30 mCi and 100 mCi of RAI to achieve successful ablation in patients with low to intermediate risk DTC. Materials and Methods: This prospective cross sectional study was conducted from April 2013 to November 2015. Inclusion criteria were patients of either gender, 18 years or older, having low to intermediate risk papillary and follicular thyroid cancers with T1-3, N0/N1/Nx but no evidence of distant metastasis. Thirty-nine patients were administered 30 mCi of RAI while 61 patients were given 100 mCi. Informed consent was acquired from all patients and counseling was done by nuclear physicians regarding benefits and possible side effects of RAI. After an average of 6 months (range 6-16 months; 2-3 weeks after thyroxin withdrawal), these patients were followed up for stimulated TSH, thyroglobulin (sTg) and thyroglobulin antibodies, ultrasound neck (U/S) and a diagnostic whole body iodine scan (WBIS) for ablation outcome. Successful ablation was concluded with stimulated Tg< 2ng/ml with negative antibodies, negative U/S and a negative diagnostic WBIS (triple negative criteria). ROC curve analysis was used to find diagnostic strength of baseline sTg to predict successful ablation. Results: Successful ablation based upon triple negative criteria was 56% in the low dose and 57% in the high dose group (non-significant difference). Based on a single criterion (follow-up sTg<2 ng/ml), values were 82% and 77% (again non-significant). The ROC curve revealed that a baseline sTg level ${\leq}7.4ng/ml$ had the highest diagnostic strength to predict successful ablation in all patients. Conclusions: We conclude that 30 mCi of RAI has similar ablation success to 100 mCi dose in patients with low to intermediate risk DTC. A baseline $sTg{\leq}7.4ng/ml$ is a strong predictor of successful ablation in all patients. Low dose RAI is safer, more cost effective and more convenient for patients and healthcare providers.

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.