• Title/Summary/Keyword: I-TEQ

Search Result 26, Processing Time 0.026 seconds

Residue and Risk Assessment of Polychlorinated dibenzo-p-dioxin/dibenzofurans in the Korean Population (다이옥신류에 의한 한국인의 폭로 현황 및 리스크 평가)

  • Kang, Youn-Seok;Park, Jong-Sei;Min, Byung-Yoon
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.270-286
    • /
    • 2002
  • The human adipose and milk samples analyzed in this study were collected at hospitals in Seoul, Masan and Jinju. The mean values of International Dioxin Toxic Equivalents (I-TEQ) of PCDDs and PCDFs in human adipose samples from the three regions were calculated as 9 pg I-TEQ/g(0.2 ~ 30 pg TEQ/g, lipid weight basis) and 8 pg I-TEQ/g (0.8 ~ 25 pg TEQ/g), respectively. The residue levels of PCDDs-TEQ and PCDFs-TEQ in human milk collected from Masan were 13 pg I-TEQ/g (lipid wt.) and 4.8 pg I-TEQ/g, respectively. On the whole, the contamination levels of these compounds in the Korean population were lower than those in the other countries. Based on the analytical data and assuming a daily intake consumption of 800 mL milk with 3% fat, the average daily intake of PCDDs/DFs via human milk for a baby weighing 5 Kg could be calculated. The daily intake of PCDDs/DFs via breast-feeding was estimated to be 39 pg/kg body weight/day for 2,3,7,8-TeCDD and 86 pg/kg/day for TEQ. These levels are far above all virtually safe dose(VSD) or tolerable daily intake(TDI) values proposed by health authorities in various countries, ranging from 0.001(US EPA) to 4 pg/kag/day (WHO).

Concentration and Characteristics of PCDDs/DFs in Soil at Cheongju City (청주시 토양 중 다이옥신 농도 및 특성)

  • Kim, Kyoung-Soo;Kim, Kyeo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.346-351
    • /
    • 2009
  • To investigate concentration and characteristics of dioxins in soil at Cheongju city, total 28 soil samples were collected. The total and I-TEQ concentration of 17 PCDDs/DFs ranged from 2.30 to 630.40 pg/g dry weight and from 0.002 to 9.79 pg I-TEQ/g dry weight with averages of 55.42 pg/g and 1.13 pg I-TEQ/g, respectively. These levels are very lower than those of around various incinerators in Korea (from n.d. to 153.23 with average value of 7.36 I-TEQ/g). The correlation between total concentration and TEQ concentration showed significant with 99% confidence interval (p-value < 0.001). The TEQ concentration as land use was high as follows; industrial area> green area> residential and commercial area> farm land. In terms of congener distribution, OCDD which is highly detected in general soil samples, was predominant and showed various fraction (from 23 to 100%). The ratios of PCDF concentration against to PCDD concentration varied as samples (from 0.1 to 2.4).

Efficient time domain equalizer design for DWMT data transmission (DWMT 데이타 전송을 위한 효율적인 시간영역 등화기 설계)

  • 홍훈희;박태윤;유승선;곽훈성;최재호
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.69-72
    • /
    • 1999
  • In this paper, an efficient time domain equalization algorithm for discrete wavelet multitone(DWMT) data transmission is developed. In this algorithm, the time domain equalizer(TEQ) consists of two stages, i.e., the channel impulse response shortening equalizer(TEQ-S) in the first stage and the channel frequency flattening equalizer(TEQ-F) in the second stage. TEQ-S reduces the length of transmission channel impulse response to decrease intersymbol interference(ISI) followed by TEQ-F that enhances the channel frequency response characteristics to the level of an ideal channel, hence diminishes the bit error rate. TEQ-S is implemented using the least-squares(LS) method, while TEQ-F is designed by using the least mean-square(LMS) algorithm. Since DWMT system also requires of the frequency domain equalizer in order to further reduce ICI and ISI the hardware complexity is an another concern. However, by adopting an well designed and trained TEQ, the hardware complexity of the whole DWMT system can be greatly reduced.

  • PDF

Determination of PCDD/F in Working Clothes of a Municipal Waste Incineration (생활폐기물 소각장 작업복 샘플의 다이옥신 분석)

  • 박순자;신정화;신정숙;정명희;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.2
    • /
    • pp.354-363
    • /
    • 2004
  • PCDD/F (Polychlorinated dibenzo-p-dioxins and dibenzofurans) in both of treated fabric and untreated fabric for working clothes of a municipal waste incineration were determinated. The treated fabric for working clothes was developed for less exposure of PCDD/F in municipal waste incinerations. The total concentrations of PCDD/F in some parts such as surface, middle layer, inside for treated and untreated fabric were investigated. The I-TEQ value of surface was 0.23370ng TEQ/g for treated fabric, 0.15355ng $.$ TEQ/g for non-treated fabric. On the other hand, the value of middle layer was 0.00077ng $.$ TEQ/g, 0.00177ng $.$ TEQ/g, respectively. The surface of the treated fabric containing high levels PCDD/F was caused by absorption of them. Therefore, PCDD/F of the treated fabric in middle layer was less I-TEQ value than that of the untreated fabric. The treated fabric makes effect on preventing PCDD/F from permeating into human body.

THE CONCENTRATION OF PCDD/FS IN FLUE GAS AND SOIL COLLECTED IN THE VICINITY OF VARIOUS INCINERATORS, KOREA

  • Kim, Kyoung-Soo;Kim, Kyeo-Keun;Kim, Jong-Guk
    • Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 2007
  • PCDD/Fs monitoring was carried out to estimate the contamination level in soil samples taken in the vicinity of the various incinerators throughout South Korea from July 2003 to December 2004. The levels ranged from N.D. to 130.39 pg I-TEQ/g (d.w.) with an average concentration of 11.38 pg I-TEQ/g (d.w.). The level of PCDD/Fs in this study is similar to that of other countries. Overall, the highest mean concentration in the soil was found at 250 m from the stack. In addition, the flue gases were analyzed in order to obtain the congener profiles of the PCDD/Fs emitted from the incinerators. The concentration of I-TEQ in the flue gas ranged from 0.33 to 21.5 ng TEQ/$Sm^3$. These levels were much lower than the concentration stipulated in the Korean emission criterion(40 ng TEQ/$Sm^3$ until 2005). The comparison of the congener patterns using cluster analysis showed that the incinerators and PCP are sources of PCDD/Fs in the soil samples according to the sampling point, but the possibility of unidentified combustion sources and vehicles exists in the case of complex industrial regions.

Analysis of PCDD/Fs and PCBs in Human Blood and Characteristics of Contamination Sources (국내 혈액에서의 PCDD/Fs 및 PCBs 분석과 오염원 특성에 관한 연구)

  • Yang, Yoon Hee;Kim, Byung Hoon;Chang, Yoon Seok
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.147-158
    • /
    • 2001
  • Polychlorinated dibenzo-p-dioxins(PCDDs), dibenzofurans(PCDFs), and biphenyls(PCBs) were analyzed by HRGC/HRMS in human blood samples from the Siwha industrial area in Korea. The PCDD/F and PCB concentrations in workers were higher than those in residents. The average TEQ concentrations of PCDD/Fs in workers and residents were 40.3 pg I-TEQs/g lipid and 16.6 pg I-TEQs/g lipid, respectively, and the total PCB concentrations were 174.1 ng/g lipid and 151.0 ng/g lipid, respectively. When applied to principal component analysis, the PCDD/F congener distributions of workers were differentiated from those of residents. But, all of them were similar to the distribution in several Korean foods. Estimated daily intake(EDI) of each person was calculated, and then only 40% to the total people were within the tolerable daily intake range(1-4pg I-TEQ/kg bw/day) suggested by WHO(1997).

  • PDF

Levels of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans in Soil and Pine needle near Industry Complex in Changwon City

  • Kim Sang-Jo;Kim Sung-Yong;Ok Gon
    • Journal of Environmental Science International
    • /
    • v.14 no.7
    • /
    • pp.629-637
    • /
    • 2005
  • Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were investigated in soil and pine needle samples taken from 16 sites of industrial and residential areas in Changwon, Korea to assess their distribution levels and to suggest the influence of industrial activities, PCDDs/DFs levels in the soil samples ranged from 0.57 to 20.79 pg I-TEQ/g dry weight with a mean value of 4.20 pg I-TEQ/g dry weight. PCDDs/DFs levels in the pine needle samples ranged from 0.39 to 8.75 pg I-TEQ/g dry weight with a mean value of 4.09 pg I-TEQ/g dry weight. In both soil and pine needle samples, the PCDDs/DFs concentrations in the industrial area sites were higher than those in the residential area sites. Homologue profiles in pine needle samples showed different patterns compared with soil samples. Based on the results of principal component analysis (PCA), it was confirmed that pine needles reflected a direct influence from local potential sources of PCDDs/DFs, showing a much higher degree of reflection than in soils. Pine needles are very useful as an indicator for monitoring or estimating the contamination of PCDDs/DFs in other areas which have been impacted by point pollution sources.

Comparison of Dioxin Analytical Results Between SP-2331 and DB-5MS Capillary Columns in the HRGC/HRMS Analysis (HRGC/HRMS에 SP-2331 및 DB-5MS 컬럼 사용시 다이옥신 결과의 비교)

  • Hong, Jongki;Yang, Jeong-Soo;Shin, Jung-Hwa;Ahn, Yun-Gyong;Lee, Dai-Woon
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.184-191
    • /
    • 2004
  • In this study, the separation of toxic dioxin 2,3,7,8-congeners by DB-5MS and SP-2331 GC columns which are widely used in HRGC/HRMS analysis was examined. Through the dioxin analysis of column performance check standard solution and fly ash sample, the isomer specific separation of 2,3,7,8-substituted dioxins from tetra to hexa-isomers on DB-5MS and SP-2331 columns were studied. The effect of I-TEQ value by these columns was also studied. The total concentrations of toxic dioxins for the column performance check standard solution were 508.4 ng/mL analyzed by DB-5MS and 515.8 ng/mL analyzed by SP-2331, respectively. The I-TEQ value obtained by both columns was shown to be almost equivalent for the column performance check standard solution and fly ash sample.

Annual Variation and Gas/Particie Partitioning of PCDD/DFs of Ambient Air at Busan, Korea (부산의 대기 중 PCDD/DFs의 연간 변화와 가스/입자상 분배)

  • Ok, Gon;Park, No-Jin;Hwang, Sung-Min;Lee, Seok-Hyung;Kim, Jee-Hoon;Kim, Sung-Yong
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.447-457
    • /
    • 2010
  • This study aims to monitor the variation of concentration of PCDD/DFs between the gaseous phase-particulate phases in the ambient air of urban area in Korea. This monitoring is evaluated by using the Junge-Pankow model and the Koa absorption model with the application of the Octanol-air partition coefficient. In this study, the ambient air samples were analyzed according to each congener group of the PCDD/DFs by HRGC/HRMS, which have been investigated for the past 5 years. In the results, the annual variation in the concentration level of $\Sigma$PCDD/DFs in TSP was increased from $1588\;fg/m^3$ in 1998 to $5123\;fg/m^3$ in 2002, and from 31 fg I-TEQ/$m^3$ to 94 fg I-TEQ/$m^3$ in the $\Sigma$I-TEQ. In the case of PUF of gaseous phase sample, their variation was increased from $1615\;fg/m^3$ in 1998 to $2237\;fg/m^3$ in 2002, and in the $\Sigma$I-TEQ from 12 fg I-TEQ/$m^3$ to 17 fg I-TEQ/$m^3$. The relative coefficient between the gas phase concentration of PCDD/DFs and the temperature was a value of 0.744; the contributive rate of the temperature to the gaseous phase concentration was 0.554. According to the results, the pattern of the coefficient of distribution based on log $p_L^0$ is similar to the ambient air of the urban areas.

Distribution characteristics of dioxin concentration in pyrolysis-gasification-melting process facilities (생활폐기물 열분해-가스화-용융공정시설에서 다이옥신의 분포특성)

  • Son, Jihwan;Kim, Kiheon;Kang, Youngyeol;Park, Sunku
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.10-16
    • /
    • 2007
  • This research was designed to investigate the formations of hazardous air pollutants in the MSWs pyrolysis-gasification-melting process. In this survey, PCDDs/PCDFs (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuran) were investigated in the two facilities (A and B facilities). In A facility, the PCDDs/DFs concentrations were 0.88, 2.29, 0.16 ng I-TEQ/$m^3$ respectively on the secondary incinerator, boiler and stack. In B facility, the PCDDs/PCDFs concentrations were 0.22, 0.05 ng I-TEQ/$m^3$ respectively on the pyrolysis-gasification-melting furnace and stack. The concentrations of PCDDs/PCDFs increased due to resynthesis during cooling process in the both facilities. High concentrations of PCDDs/PCDFs isomers were founded as 2, 3, 4, 7, 8-PeCDF, 2, 3, 4, 6, 7, 8-HxCDF and 1, 2, 3, 6, 7, 8-HxCDF orderly in A facility, and 2, 3, 4, 7, 8-PeCDF, 1, 2, 3, 7, 8-PeCDD and 2, 3, 4, 6, 7, 8-HxCDF orderly in B facility.