• Title/Summary/Keyword: I-Pin

Search Result 267, Processing Time 0.024 seconds

Modeling and simulation of VERA core physics benchmark using OpenMC code

  • Abdullah O. Albugami;Abdullah S. Alomari;Abdullah I. Almarshad
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3388-3400
    • /
    • 2023
  • Detailed analysis of the neutron pathway through matter inside the nuclear reactor core is exceedingly needed for safety and economic considerations. Due to the constant development of high-performance computing technologies, neutronics analysis using computer codes became more effective and efficient to perform sophisticated neutronics calculations. In this work, a commercial pressurized water reactor (PWR) presented by Virtual Environment for Reactor Applications (VERA) Core Physics Benchmark are modeled and simulated using a high-fidelity simulation of OpenMC code in terms of criticality and fuel pin power distribution. Various problems have been selected from VERA benchmark ranging from a simple two-dimension (2D) pin cell problem to a complex three dimension (3D) full core problem. The development of the code capabilities for reactor physics methods has been implemented to investigate the accuracy and performance of the OpenMC code against VERA SCALE codes. The results of OpenMC code exhibit excellent agreement with VERA results with maximum Root Mean Square Error (RMSE) values of less than 0.04% and 1.3% for the criticality eigenvalues and pin power distributions, respectively. This demonstrates the successful utilization of the OpenMC code as a simulation tool for a whole core analysis. Further works are undergoing on the accuracy of OpenMC simulations for the impact of different fuel types and burnup levels and the analysis of the transient behavior and coupled thermal hydraulic feedback.

A clinical case of hybrid telescopic double crown using friction pin with an isolated few remaining teeth (고립된 소수 잔존치 환자에서 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관 국소의치의 임상증례)

  • Sohn, Sang-Hyuk;Cho, Jin-Hyun;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.80-86
    • /
    • 2016
  • A few authors have reported good clinical results using double crown removable partial denture (RPD) with a few remaining teeth. Hybrid telescopic double crown is a good indication for a patient with poor periodontal condition and/or few remaining teeth after extraction, especially located in cross-arch position. In this case, there was a poor periodontal condition with teeth mobility. Several teeth with poor prognosis were extracted. Remaining anterior teeth was restored with fixed prostheses and edentulism was restored with Kennedy class I removable partial denture in maxilla. In mandible, it was hard to restore with clasp removable partial prostheses because of bilaterally isolated remaining teeth so that hybrid double crown removable partial denture with friction pin was suitable for this case. The objective of this report is to discuss the characteristics and the utility of hybrid double crown prostheses using a few remaining teeth in mandible.

Development of a Coded-aperture Gamma Camera for Monitoring of Radioactive Materials (방사성 물질 감시를 위한 부호화 구경 감마카메라 개발)

  • Cho, Gye-Seong;Shin, Hyung-Joo;Chi, Yong-Ki;Yoon, Jeong-Hyoun
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.257-261
    • /
    • 2004
  • A coded-aperture gamma camera was developed to increase the sensitivity of a pin hole camera made with a pixellated CsI(Tl) scintillator and a position-sensitive photomultiplier tube. The modified round-hole uniformly redundant array of pixel size $13{\times}11$ was chosen as a coded mask considering the detector spatial resolution. The performance of the coded-aperture camera was compared with the pin hole camera using various forms of Tc-99m source to see the improvement of signal-to-noise ratio or the improvement of the sensitivity. The image quality is much improved despite of a slight degradation of the spatial resolution. Though the camera and the test were made for low energy case, but the concept of the coded-aperture gamma camera could be effectively used for the radioactive environmental monitoring and other applications.

Analysis of Frequency Characteristic of Travelling-Wave Photodetector Using the FDTD Method (FDTD를 이용한 Travelling-Wave Photodetector의 주파수 특성 해석)

  • 공순철;이정훈;이승진;최영완
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.14-15
    • /
    • 2000
  • We study the microwave characteristics of traveling-wave photodetector using the finite-difference time-domain method. We present two parameters for design, the width of PIN region and the thickness of i-layer, and analyze TWPD's property in frequency domain.

  • PDF

인터넷 보안 동향 회고와 전망 분석

  • Jeon, Yong-Hee
    • Review of KIISC
    • /
    • v.18 no.1
    • /
    • pp.78-81
    • /
    • 2008
  • 작년 한 해 동안 국내 정보보호분야에서는 악성코드의 증가, 정보통신망법 개정, i-PIN 도입 등 커다란 사안이 많았다. 특히 통합보안솔루션의 부상과 시장 확대가 국내외의 화두가 되기도 하였다. 본고에서는 작년 국내외의 보안 기술 동향에 대하여 회고하여 보고, 금년 한 해 동안의 전망에 대하여 시만텍 등의 분석 보고서를 중심으로 기술하고자 한다. 이를 통하여 효과적인 보안 기술의 연구개발과 정책 수립에 지침이 되었으면 한다.

Development of Spectroscopy Toolkit for Spectrum Measurement Experiments Using a CsI(Tl)/PIN Diode Detector

  • Nam, Young-Mi;Kim, Han-Soo;Ha, Jang-Ho;Lee, Jae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.77-80
    • /
    • 2010
  • The spectroscopy toolkit has been developed and tested. The toolkit consists of a CsI(Tl)/PIN diode detector, integrated electronics, and a multi.channel.analyzer and its size was 40 cm(width) by 20 cm(length) by 6 cm(high). It is compact, very portable and simpler and cheaper compared to the conventional spectroscopy system. The gamma energy resolutions of the toolkit were 7.9% for the 660 keV of $^{137}Cs$ and 4.9% for 1,332 keV of $^{60}Co$ respectively. The linearity for gamma energies was good. When the energy spectrum of a ceramic sample containing $^{232}Th$ was measured with the spectroscopy toolkit for 20 minutes, there were significant peaks of the heavy metal. These results show that the resolution of the spectroscopy toolkit is sufficient to accumulate a quality spectrum in a few minutes by using weak, encapsulated commercial sources. Furthermore a toolkit experiment that how to measure energy spectra using the toolkit, and how to identify specific isotopes in a pottery piece, could be widely adopted for education and even for more sophisticated and higher level experiments.

A Study on Online Authenticate Themselves Techniques according to Resident Registration Number collect Prohibited (주민등록번호 수집금지에 따른 온라인 본인인증 기법 연구)

  • Son, Seung-wan;Kim, Kwang-seok;Lee, Gang-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.271-274
    • /
    • 2013
  • From February 18, 2013, an information and communications service provider, we will not be able to collect the resident registration number by paragraph 2 of Article 23 of the Act on the Promotion of the use and protection of information and information network. Rather than a revision in accordance with resident registration number, than these laws, it had been used in the alternative, such as OTP authentication phone authentication I-PIN authentication of certificates that are recognized as such authentication. In this paper, we propose a new online identity authentication technology was and Utilization of IMEI, the OTP to introduce online identity authentication technology replacing the resident registration number.

  • PDF

Research of the Fairness about On-line Testing (원격시험 응시자의 시험 공정성에 관한 연구)

  • Park, Kee-Hong;Jang, Hae-Sook
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.67-73
    • /
    • 2011
  • Teaching and learning between instructor and students and testing for evaluation are progressed remotely in distance education. Current research trends are focused primarily on the distance learning services. Testing to estimate the effectiveness of training is important as lecturing, but it has not been studied much until now. In this paper, we suggest DEIS(Distance Education Invigilation System) for a fair examination. DEIS identify examinees by verifying their real name with I-PIN and comparing the still image of the candidates the software stored on the server and the photos that are registered at the enrollment.

The High Efficiency of Amorphous-Si Solar Cells Prepared by Photo-CVD System (광(光) CVD 법(法)에 의한 a-Si 태양전지(太陽電池)의 고효율화에 관한 연구(硏究))

  • Kim, Tae-Seoung
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.46-53
    • /
    • 1985
  • Hydrogenated amorphous silicon solar cells which are fabricated by photo-chemical vapor deposition (photo-CVD) system has been investigated. In the photo-CVD system which consists of three separate reaction chambers, low-pressure mercury lamp has been used as a light source. The main reactant ($Si_2H_6/He$) gases which are premixed with a small amount of mercury vapor in a mercury-vaporizer kept at $50^{\circ}C$ have been used. Using $C_2H_2$ and $SiH_2(CH_3)_2$ as the carbon source, p-type wide band gap a-SiC:H films have been obtained. The result has been found that the undoped layers of the pin/substrate solar cells are influenced by the residual impurities, such as phosphorus and boron during the deposition process. By minimizing the effect of the impurities in the i-layer and optimizing conditions at the p-layer and p/i interface, the energy conversion efficiency of 9.61 % under AM-1 ($100mW/Cm^2$) has been achieved for pin/substrate solar cells illuminated through their p-layers, using the three separate reaction chamber apparatus. It is expected that a-SiC:H solar cells with the energy conversion efficiency over 10% have been fabricated by Photo-CVD method.

  • PDF