• Title/Summary/Keyword: I&C equipment

Search Result 195, Processing Time 0.026 seconds

Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System (일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석)

  • Lee, Joon-Koo;Sohn, Kwang-Young;Park, Hee-Seok;Park, Heui-Yun;Koo, In-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF

ATWS Frequency Quantification Focusing on Digital I&C Failures

  • Kang Hyun Gook;Jang Seung-Cheol;Lim Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.184-195
    • /
    • 2004
  • The multi-tasking feature of digital I&C equipment could increase risk concentration because the I&C equipment affects the actuation of the safety functions in several ways. Anticipated Transient without Scram (ATWS) is a typical case of safety function failure in nuclear power plants. In a conventional analysis, mechanical failures are treated as the main contributors of the ATWS. This paper quantitatively presents the probability of the ATWS based on a fault tree analysis of a Korea Standard Nuclear Power Plant is also presented. An analysis of the digital equipment in the digital plant protection system. The results show that the digital system severely affects the ATWS frequency. We also present the results of a sensitivity study, which show the effects of the important factors, and discuss the dependency between human operator failure and digital equipment failure.

Development of Reliability Evaluation System for I&C System Upgrade (원자력발전소 I&C계통 설비개선을 위한 평가시스템 개발)

  • Chung, Hak-Young;Kang, Hyeon-Tae;Sung, Chan-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1852-1858
    • /
    • 2007
  • To Increase availability and to enhance the safety, the modernization of Instrumentation & Control (I&C) systems is considered. The extended use of the digital technology lets nuclear power plants(NPPs) to replace their old analog systems with some proven digital systems. To adapt digital equipment to plants effectively and systematically, however, there must be an essential prerequisite, which is to evaluate current I&C equipment. This paper shows a practical methodology to evaluate the current status and reliability of I&C systems of NPPs using Reliability Evaluation System(RES) before performing upgrades or replacements for systems. The proposed method was applied to KORI Unit 2. The proposed method shows the current status of operating I&C systems effectively for upgrading I&C systems.

원전 I&C FSE 분류기준과 이에 따른 상용 소프트웨어의 원전 사용 승인기준

  • 김장열;권기춘
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.1041-1046
    • /
    • 1995
  • 본 논문에서는 원전 I&C Function System Equipment (FSE)의 분류기준을 제시하기 위하여 IEEE 730.1, IEEE 828, IEEE 1012 및 IEC 1226의 관련 표준들을 비교 분석하여 I&C FSE를 근간으로 계측제어 소프트웨어를 원전 I&C 계통의 기능에 따라 Type I, Type II, Type III 및 Type IV로 분류할 수 있는 분류기준, 분류절차 및 예를 제시하였다. 또한, 본 논문의 분류기준을 토대로 하여 최근 이슈가 되고 있는 상용 소프트웨어 (Commercial Off The Shelf Software)의 원전 사용 승인기준을 제시하였다.

  • PDF

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Design and Development of Signal Transmitting POD for Aircraft Application (항공기용 신호 송출 POD의 설계 및 개발)

  • Kim, Jee-heung;Kwak, Young-kil;Kim, Kichul;Park, Joo-rae
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this research, we develop an airborne equipment radiating S/C-band signal to a target located at a long distance. RF interface of the equipment comprises band-specific transmitters and an broadband antenna to satisfy EIRP(effective isotropic radiated power) requirements. The equipment is in a shape of a POD like an aircraft fuel tank. The measured weight of the equipment is 119.8 kg, the CG(center of gravity) is 1391.35 mm and the MOI(moment of inertia) are 46.07 ± 0.05(Iyy) kg·㎡, 45.36 ± 0.09(Izz) kg·㎡. All results are found to meet the requirements for aircraft installation. To verify flight safety, EMI(electromagnetic interference) tests (RE102, CE102), environmental tests (high/low temperature operation, altitude), intra-system EMC(electromagnetic compatibility) and HERP(hazards electromagnetic radiation personnel) tests have been conducted and all the test results met the requirements. It is confirmed that the equipment could be mounted on the aircraft by meeting all electrical and mechanical requirements.

Comparative Study of AI Models for Reliability Function Estimation in NPP Digital I&C System Failure Prediction (원전 디지털 I&C 계통 고장예측을 위한 신뢰도 함수 추정 인공지능 모델 비교연구)

  • DaeYoung Lee;JeongHun Lee;SeungHyeok Yang
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.1-10
    • /
    • 2023
  • The nuclear power plant(NPP)'s Instrumentation and Control(I&C) system periodically conducts integrity checks for the maintenance of self-diagnostic function during normal operation. Additionally, it performs functionality and performance checks during planned preventive maintenance periods. However, there is a need for technological development to diagnose failures and prevent accidents in advance. In this paper, we studied methods for estimating the reliability function by utilizing environmental data and self-diagnostic data of the I&C equipment. To obtain failure data, we assumed probability distributions for component features of the I&C equipment and generated virtual failure data. Using this failure data, we estimated the reliability function using representative artificial intelligence(AI) models used in survival analysis(DeepSurve, DeepHit). And we also estimated the reliability function through the Cox regression model of the traditional semi-parametric method. We confirmed the feasibility through the residual lifetime calculations based on environmental and diagnostic data.

Thermal Load Simulation Analysis on Model Building Estimating Optimum Heat Source Capacity (최적 열원용량 산정을 위한 모델건물 공조부하 시뮬레이션 분석)

  • Park, Jong-Il;Kim, Se-Hwan;Lee, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.427-433
    • /
    • 2007
  • Generally, H.V.A.C load capacity in early planning phase can presume with maximum thermal load. Basic data can prove by air conditioning equipment system data analysis at existing building. There are poor and not reliable alternative presentation. In this paper, measured data after use H.V.A.C load calculation K-load program reply choosing standard building and variables simulation. And I founded peak load correlation graph and mode for several kinds of variable and contents of size. I wish that equipment designer is beaconed to produce optimum capacity at building as quantitative through this result.

A Study for Cyber Situation Awareness System Development with Threat Hunting (위협 헌팅을 적용한 사이버 상황인식 시스템 개발에 관한 연구)

  • Lee, Jaeyeon;Choi, Jeongin;Park, Sanghyun;Kim, Byeongjin;Hyun, Dae-Won;Kim, Gwanyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.807-816
    • /
    • 2018
  • Threat hunting is defined as a process of proactively and iteratively searching through networks to detect and isolate advanced threats that evade existing security solutions. The main concept of threat hunting is to find out weak points and remedy them before actual cyber threat has occurred. And HMM(Hunting Maturity Matrix) is suggested to evolve hunting processes with five levels, therefore, CSOC(Cyber Security Operations Center) can refer HMM how to make them safer from complicated and organized cyber attacks. We are developing a system for cyber situation awareness system with pro-active threat hunting process called unMazeTM. With this unMaze, it can be upgraded CSOC's HMM level from initial level to basic level. CSOC with unMaze do threat hunting process not only detecting existing cyber equipment post-actively, but also proactively detecting cyber threat by fusing and analyzing cyber asset data and threat intelligence.