• Title/Summary/Keyword: Hysteresis motor dynamic analysis

Search Result 5, Processing Time 0.029 seconds

A Study of Dynamic Characteristic Analysis for Hysteresis Motor Using Permeability and Load Angle by Inverse Preisach Model (역 프라이자흐 모델에 의한 투자율과 부하각을 이용한 히스테리시스 전동기의 동적 특성 해석 연구)

  • Kim, Hyeong-Seop;Han, Ji-Hoon;Choi, Dong-Jin;Hong, Sun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.2
    • /
    • pp.262-268
    • /
    • 2019
  • Previous dynamic models of hysteresis motor use an extended induction machine equivalent circuit or somewhat different equivalent circuit with conventional one, which makes unsatisfiable results. In this paper, the hysteresis dynamic characteristics of the motor rotor are analyzed using the inverse Preisach model and the hysteresis motor equivalent circuit considering eddy current effect. The hysteresis loop for the rotor ring is analyzed under full-load voltage source static state. The calculated hysteresis loop is then approximated to an ellipse for simplicity of dynamic computation. The permeability and delay angle of the elliptic loop apply to the dynamic analysis model. As a result, it is possible to dynamically analyze the hysteresis motor according to the applied voltage and the rotor material. With this method, the motor speed, generated torque, load angle, rotor current as well as synchronous entry time, hunting effect can be calculated.

Moving Mesh Technique for Dynamic Characteristics Analysis of Permanent Magnet Linear Synchronous (영구 자석형 선형 동기전동기의 동특성 해석을 위한 이동 메쉬 기법)

  • Woo, Kyung-Il;Kwon, Byung-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.53-58
    • /
    • 2001
  • This paper describes a moving mesh technique for dynamic characteristics analysis of permanent magnet linear synchronous motor with the secondary aluminium sheet. The moving mesh technique applied to the linear induction motor can be used to analyze the linear synchronous motor with the rectangular permanent magnet. But in case of the permanent magnet with taper, the shape of the permanent magnet is presented. The time-stepped finite element method is used for the dynamic characteristics simulation of the permanent magnet linear synchronous motor, The results of application example(hysteresis current controlled inverter fed control) such as thrust, current and flux plots are shown.

  • PDF

Analysis of the Dynamic Characteristics of the Linear Motors (선형 모터의 동특성 분석)

  • Seol, Jin-Soo;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.258-263
    • /
    • 2005
  • The nearest variety of the industrial world requires using the high precision and resolution positioning technology to do a semi-conductor, information field , and measurement field. It is especially important for the positioning technology that makes up a proper controller, is affected by the minimal heat and vibration, and can control a structurally generated non-linear friction factor to determine the efficiency of the system. The paper is to analyze the vibration characteristic according to the speed of linear motor and grasp the dynamic characteristic through the modal test and show the verification of the experimental result and design parameters by using FEM(Finite Element Method). Also, it shows the optimum standard analyzed the acceleration patterns of the moving part that lead to the vibration source in linear motor. It presents the analyzed dynamic of linear motor in compliance with a change of the non-linear factor.

  • PDF

Direct Torque Control according to Flux and Torque of Hysterisis Band (자속 및 토오크 히스테리시스 밴드폭에 따른 직접토오크 제어)

  • Choi, Youn-Ok;Jeong, Sam-Yong;Kim, Dae-Gon;Kim, Pyung-Ho;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1206-1208
    • /
    • 2001
  • Direct torque control(DTC) of AC motor has the fast torque and flux dynamic responses even though it has very simple scheme to implement. DTC is also very simple in its implementation because it needs only two hysteresis comparators and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple, switching frequency and current harmonics. Therefore, authors analysis flux and torque hysteresis bands is suggested considering switching frequency and harmonic distortion of currents.

  • PDF

Low-Cost Position Sensorless Switched Relutance Motor Drive Using a Single-Controllable Switch Converter

  • Yang, Hyong-Yeol;Kim, Jae-Hyuck;Krishnan, R.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.75-82
    • /
    • 2012
  • Elimination of rotor position sensors mechanically coupled with the rotor shaft is attractive to variable speed drives primarily due to increased system reliability and cost reduction. In this regard, search for a simple and robust position sensorless control has been intensified in past few years specifically for low-cost, high-volume applications such as home appliances. This paper describes a new parameter insensitive position sensorless control for switched reluctance motor (SRM) drives satisfying such a need in this market segment. Two consecutive switch-on times of the controllable switch in hysteresis current control are compared to estimate the rotor position and speed. The proposed sensorless control algorithm is very simple to implement since it does not depend on extensive computation or any additional hardware. In addition, the proposed method is robust in that its dynamic performance is least affected by system parameter variations. The proposed approach is demonstrated on a single-controllable-switch-converter-driven SRM with two-phases that lends itself to a system with low cost and compact packaging which comes close to the intended applications. Analysis and simulation results followed by experimental verification are presented to demonstrate the feasibility of the proposed sensorless control method.