• Title/Summary/Keyword: Hysteresis current control

Search Result 173, Processing Time 0.036 seconds

Everett Function Formulation Using Minor Loops and Magnetization-dependent Model and Hysteresis Characteristics Simulation (마이너루프와 자화의존 모델을 이용한 에버? 함수 생성과 히스테리시스 특성 시뮬레이션)

  • Kim, Hyeoung-Seop;Hong, Sun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1725-1731
    • /
    • 2017
  • In hysteresis simulation, the Preisach model is most widely used as the reliability. However, since the first-order transition curves used in the conventional Preisach model are very inconvenient for actual measurement, many researches have been made to simplify them. In this study, the minor loops obtained along the initial magnetization curve are used to obtain the Everett function used in the Preisach model. In other words, The Everett table is constructed by using the minor loops, and are applied to the magnetization dependent Preisach model to reconstruct the Everett table. In order to minimize the error, the spline interpolation method is used to complete the final Everett table and the hysteresis loop simulation is performed with the Everett table. Furthermore, it is applied to the inductor analysis to perform not only sinusoidal wave and square wave drive but also PWM wave drive considering hysteresis. The validity of the proposed method is confirmed by comparison with simulation and experiment.

Two Vector Based Direct Power Control of AC/DC Grid Connected Converters Using a Constant Switching Frequency

  • Mehdi, Adel;Reama, Abdellatif;Benalla, Hocine
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1363-1371
    • /
    • 2017
  • In this paper, an improved Direct Power Control (DPC) algorithm is presented for grid connected three phase PWM rectifiers. The new DPC approach is based on two main tasks. First the optimization of the look-up table, which is well-known in conventional DPC, is outlined for selecting the optimum converter output voltage vectors. Secondly a very simple and effective method is used to directly calculate their duty cycles from the power errors. Therefore, the measured active and reactive powers are made to track their references using hysteresis controllers. Then two vectors are selected and applied during one control cycle to minimize both the active and reactive power ripples. The main advantages of this method are that there is no need of linear current controllers, coordinates transformations or modulators. In addition, the control strategy is able to operate at constant switching frequencies to ease the design of the power converter and the AC harmonic filter. The control exhibits a good steady state performance and improves the dynamic response without any overshoot in the line current. Theoretical principles of the proposed method are discussed. Both simulation and experimental results are presented to verify the performance and effectiveness of this control scheme.

Development of 3 Phase PWM Converter using Analog Hysteresis Current Controller (아날로그 히스테리시스 전류 제어기를 적용한 3상 PWM 컨버터 개발)

  • Lee Young-kook;Noh Chul-won
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.372-376
    • /
    • 2001
  • Due to several advantages of Pulse Width Modulation(PWM) Converter, such as unity power factor operation, elimination of low-order harmonics and regeneration of motor braking energy to source, the application range of PWM Converter has been rapidly extended in industrial application. Nowadays, vector control algorithm and space vector PWM(SVPWM) method are applied to improve the performances of PWM Converter, but vector control algorithm and SVPWM require to use Microprocessor and other digital devices in hardware, causing costly and somewhat large dimension system. In every practical application of energy conversion equipments, the design and implementation should be carried out considering cost and performance. High performance and low cost is the best choice for energy conversion equipments. So, this paper presents the practical design method and implementation results of 3-phase PWM Converter with analog hysteresis current controller, and verifies the performances of unit power factor operation and energy regeneration operation via experimental results.

  • PDF

A High Performance Current Control Stratege for a BLDC Motor (BLDC 전동기를 위한 고성능 전류 제어 기법)

  • Kim, Sang-Hoon;Kim, Jin-Yong
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.125-132
    • /
    • 2002
  • In this paper, a high performance current control strategy for a Brushless DC Motor is presented. The proposed strategy is based on the ramp comparison PI current control with the predictive voltage compensation. The proposed strategy is compared with the hysteresis current control strategy. The proposed method can improve the current waveforms, and it can reduce the torque ripples. So the proposed strategy is suitable to a high performance current control strategy for a Brushless DC Motor. The simulation and experimental results for a laboratory Brushless DC motor drive system confirm the validity of the proposed strategy.

  • PDF

Performance Improvement of Induction Motor in Voltage Shortage State (전압 부족 상태 시 유도 전동기 성능 개선)

  • Kim, Hye-Seung;Kim, Jeong-Ha;Hong, Chan-Ook;Kim, Kyung-Seo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.466-471
    • /
    • 2009
  • The vector control algorithm has come to be used as induction motor for high performance torque and response improvement. This paper deals with new control algorithm which improves the performance of the rotor flux control by combining the conventional current controller with the flux controller and the hysteresis controller. In voltage shortage condition, proposed algorithm shows that the response and the stability can be improved both in the simulation results and in the experimental results.

A Study on the Operation Characteristics of a Reactive Power Copensator using PWM Converter (PWM 콘버어터를 이용한 순시무효전력 보상장치의 동작해석)

  • Kwon, Ki-Hyun;Kwon, Soon-Jae;Kim, Cheul-U;Whang, Yong-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.310-312
    • /
    • 1989
  • From the viewpoint of an effective energy use, many method for reactive power compensation has been developed. Among of the reactive power compensation, this paper describes the relation of operation interpretation, filter, hysteresis width and switching time of current controlled PWM converter which has excellent reactive power compensation. This current controlled PWM convertor is excellent the view of reactive power compensation by current control method using hysteresis comparator method, but is required element of high response characteristics. Therefore this paper offers the series of data for system considering switching characteristics of switching element.

  • PDF

A Hysteresis Current Controller with Improved Voltage Waveform using N.P.C Structure (N.P.C 구조에 의한 히스테리시스 전류제어기의 전압파형 개선)

  • 김윤호;이병송
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.51-57
    • /
    • 1997
  • A new current controlled PWM technique with N.P.C structure is proposed in this paper. A current controlled PWM technique with neutral-point-clamped pulsewidth modulation inverter composed of main switching devices which operates as switches for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. This inverter output contains less harmonic content as compared with that of a conventional current controlled PWM type. In addition, the proposed current controlled PWM technique has lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Two inverters are compared analytically. The improved voltage waveform of current controlled PWM with N.P.C structure is analyzed and the performance is investigated by the computer simulation.

  • PDF

Compensation of Time Delay in Induction Motor Vector Control System Using DQ Transformation (유도전동기 벡터제어 시스템에서 DQ변환을 이용한 시간지연 보상)

  • 최병태;권우현;박철우
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1001-1008
    • /
    • 2003
  • A time-delay compensation method for vector control system is proposed that can compensate for voltage and current distortions resulting from a time delay in the overall system due to the low pass filter, hysteresis control inverter, microprocessor program computation time, and so on. The proposed scheme estimates the time delay using the difference between the Q-axis stator current command and the time-delayed actual Q-axis stator current in a synchronous reference frame, then compensates the time delay in the voltage and current using the angular displacement of a DQ transformation. Accordingly, the proposed scheme can accurately compensate for the time delay related to the overall system, thereby significantly improving the performance of the vector control system, as verified by simulation and experiment.

Reduced Switch Count Topology of Current Flow Control Apparatus for MTDC Grids

  • Diab, Hatem Yassin;Marei, Mostafa Ibrahim;Tennakoon, Sarath B.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1743-1751
    • /
    • 2016
  • The increasing demand for high voltage DC grids resulting from the continuous installation of offshore wind farms in the North Sea has led to the concept of multi-terminal direct current (MTDC) grids, which face some challenges. Power (current) flow control is a challenge that must be addressed to realize a reliable operation of MTDC grids. This paper presents a reduced switch count topology of a current flow controller (CFC) for power flow and current limiting applications in MTDC grids. A simple control system based on hysteresis band current control is proposed for the CFC. The theory of operation and control of the CFC are demonstrated. The key features of the proposed controller, including cable current balancing, cable current limiting, and current nulling, are illustrated. An MTDC grid is simulated using MATLAB/SIMULINK software to evaluate the steady state and dynamic performance of the proposed CFC topology. Furthermore, a low power prototype is built for a CFC to experimentally validate its performance using rapid control prototyping. Simulation and experimental studies indicate the fast dynamic response and precise results of the proposed topology. Furthermore, the proposed controller offers a real solution for power flow challenges in MTDC grids.

Torque Control Strategy for High Performance SR Drive

  • Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.538-545
    • /
    • 2008
  • This paper attempts to summarize torque control strategy for high performance SR drive. There are primarily two strategies for torque control. One method is direct torque control, which uses the simple control scheme and hysteresis controller to reduce the torque ripple. Another method is indirect torque control, which uses the complicated algorithms or simple distribution function to distribute each phase torque and obtain current command. The current controller is used to control phase torque by a given current command. In order to compare these two strategies of torque control, five torque control methods are introduced. The advantages and disadvantages of each method are presented. At last, they are verified by some simulations and experimental results.