• Title/Summary/Keyword: Hypochlorous acid water

Search Result 26, Processing Time 0.039 seconds

Isolation, Characterization, and Control of Pseudomonas kribbensis and Pantoea vagans that cause Soft-rot Disease Isolated from Chinese Cabbages

  • Lee, Kang Wook;Kim, Geun Su;Kim, Jeong A;Kwon, Do Young;Lee, Jin Ju;Kim, Il Chul;Kim, Sang Gu;Kim, Tae Seok;Lee, Sang Yun
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.55-62
    • /
    • 2022
  • The bacterial soft-rot disease is one of the most critical diseases in vegetables such as Chinese cabbage. The researchers isolated two bacteria (Pseudomonas kribbensis and Pantoea vagans) from diseased tissue samples of Chinese cabbages and confirmed them as being the strains that cause soft-rot disease. Lactic-acid bacteria (LAB), were screened and used to control soft-rot disease bacteria. The researchers tested the treatments with hypochlorous acid water (HAW) and LAB supernatant to control soft-rot disease bacteria. The tests confirmed that treatments with the HAW (over 120 ppm) or LAB (Lactobacillus plantarum PL203) culture supernatants (0.5 mL) completely controlled both P. kribbensis and P. vagans.

Model development for chlorine generation using electrolysis (전기분해에 의한 잔류염소 생성 예측 모델 개발)

  • Sohn, Jinsik;Lee, Sunjae;Shin, Chorong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.331-337
    • /
    • 2009
  • Electrolysis produces hypochlorous acid by using a small quantity of NaCl as electrolyte. This process maximizes the stabilization of drinking water through the control of chlorine residual concentration. This study investigated free chlorine generation by an electrolytic method using $Ti/IrO_2$ and stainless steel. The generation of free chlorine was increased with increasing hydraulic retention time, voltage, chlorine ion concentration and the number of electrodes. However, the change of pH did not affect the generation of free chlorine. There was no significant difference on the behavior of chlorine concentration between electrolytic method and NaOCl injection. In this study, the concentration of free chlorine predicted model based on power functional model was developed various under conditions. Electrolysis free chlorine generation model can be effective tool in the estimation of free chlorine generation.

Generation and Characteristics Analysis of Swine Manure for Introducing Biogas System (논문 - 바이오가스화 도입을 위한 양돈농가 가축분뇨 발생 및 특성분석)

  • Choi, Eun-Hee;Yoon, Young-Man;Kim, Chang-Hyun
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.25-32
    • /
    • 2011
  • The 21 livestock farms considering future installation of biogas systems were studied. These farms were examined how to raise the livestock, to treat manure, to operate facility with respect to manure characteristics. The 15 farms out of 21 farms have applied to the marine dumping and consignment treatment for treating manure and even farms which have equipped liquid fertilizing system have less capacity facility than legal standards. Characteristics of manure were affected by the scale of swine barn, clean water usage, frequency of cleaning, cleaning method, feces-urine separating method, etc. Retention time in storage (over 20 days) has resulted in lower concentration of organic matter which could reduce biogas production. This indicates that systematic barn management system is required. Inhibition tests showed that disinfectant and citric acid did not affected digestion rates at 10 times higher concentration than recommendation. However hypochlorous acid is likely to affect the anaerobic microbial activity.

  • PDF

Investigation on the Technology Trend in Electrolyzed Sterilizing Water by the Patent Analysis (특허분석을 통한 전해살균수의 기술 동향 연구)

  • Kang, Kyung-Seok;Kim, Tae-il;Lee, Ho-il;Han, Hye-jung;Park, Soo-gil;Kim, Han-ju;Han, Sam-Duck;Park, Kunyik;Rhee, Young-Woo
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.188-194
    • /
    • 2010
  • The electrolyzed sterilizing water is useful functional aqueous solution, which is produced by electrolyzing aqueous solution. Electrolytic supplement such as salt or hydrochloric acid is added into tap water. Electrolyzed sterilizing water is classified as three types; strongly acidic electrolyzed water, weakly acidic electrolyzed water, and sodium hypochlorite water. In this study, preparation principles, advantages, and disadvantages of electrolyzed sterilizing water were analyzed. The technology trend in electrolyzed sterilizing water was analyzed based on patent application year, countries, main applicants, and each technologies.

The Study of Characteristics of Electrolytic Water (전해수의 특성에 관한 연구)

  • Lee, Chan-Woo;Bae, Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.18 no.6 s.91
    • /
    • pp.43-48
    • /
    • 2006
  • Electrolytic water(EW), studied in recent decades in the Japan, Russia and United State of America, have shown promise as a method of disinfection whereby low levels of free chlorine, sodium hypochlorite, or hypochlorous acid may be produced in situ in Nacl-containing solution. These methods have shown promise in destruction of microorganisms in medical, dental environment, and in the agriculture and food industry. A recently EW treatment system was evaluated for reducing scouring agent and other surfactants in the washing and scouring process of textile industry Unfortunately, there is, to my knowledge, no serious studies of the properties of EW for textile industry In order to study the characteristics of EW and confirm the possibility of applications in textile industry processes, the pH, surface activity, penetration force, surface tension, and contact angle of EW was measured under various conditions. In general terms, What all this shows is that there is fundamental difference between the properties of EW and that of distilled water.

Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement (잔류염소 측정용 전기화학센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

A Study on Water Quality Management Methods of Waterscape Facilities in Accordance Legislation of Water Quality Criteria (수질기준 법제화에 따른 물놀이형 수경시설의 수질관리방안 연구)

  • Na, Kyung-Ho;Yong, Jeong-Ju;Kim, Ji-Soo;Byeon, Ju-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.487-493
    • /
    • 2017
  • This study was conducted to propose measures of water quality management as the water criteria for waterscape facilities which have been highlighted as alternatives to wading pools in summer season was legislated. The number of public waterscape facilities has reached 290 sites in Gyeounggi province and 971 sites in South Korea in 2017. The water tank capacity of 80.3 % public waterscape facilities was less than $100m^3$. Facilities with disinfection system were only 6.5 % and facilities with filtration function were also very low at 6.9 %. Most of the waterscape facilities, about 93%, are expected to be vulnerable to complying with revised water quality criteria because they have to be disinfected by handling. Chlorine disinfectants, which are more persistent than ozone or ultraviolet sterilization methods, are more preferred. However, care should be taken when adding disinfectans because hypochlorous acid, which is an effective component of chlorine disinfectant, remains after the disinfection, but it is easily decomposed with time. For this study, ${\bigcirc}{\bigcirc}$ park floor fountain with a capacity of $63m^3$ was selected and the amount of free residual chlorine concentration was measured by injecting a certain amount of chlorine bleach. As a result, it took 5 hours to decrease from the water quality standard of 4 mg/L to 0.04 mg/L. If the waterscape facility is operated for 7 to 8 hours, the chlorine bleach should be re-injected after 5 hours. In addition, the problem of pH increase due to the input of chlorine disinfectant is expected, and the neutralization method using vinegar was proposed.

Application of Response Surface Methodology to Optimize the Performance of the Electro-Chlorination Process (전기분해 염소소독공정의 반응표면분석법을 이용한 차아염소산나트륨 발생 최적화)

  • Ju, Jaehyun;Park, Chan-gyu
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.3
    • /
    • pp.167-175
    • /
    • 2022
  • Background: Disinfection is essential to provide drinking water from a water source. The disinfection process mainly consists of the use of chlorine and ozone, but when chlorine is used as a disinfectant, the problem of disinfection by-products arises. In order to resolve the issue of disinfection by-products, electro-chlorination technology that produces chlorine-based disinfectants from salt water through electrochemical principles should be applied. Objectives: This study surveys the possibility of optimally producing active chlorine from synthetic NaCl solutions using an electro-chlorination system through RSM. Methods: Response surface methodology (RSM) has been used for modeling and optimizing a variety of water and wastewater treatment processes. This study surveys the possibility of optimally producing active chlorine from synthetic saline solutions using electrolysis through RSM. Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. Results: Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. A central composite design (CCD) was applied to determine the optimal experimental factors for chlorine production. Conclusions: The concentration of the synthetic NaCl solution and the distance between electrodes had the greatest influence on the generation of hypochlorite disinfectant. The closer the distance between the electrodes and the higher the concentration of the synthetic NaCl solution, the more hypochlorous acid disinfectant was produced.

Role of Electrode Reaction of Electrolyte in Electrokinetic-Fenton Process for Phenanthrene Removal (동전기-펜턴 공정에서 전해질의 전극반응이 처리효율에 미치는 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • The effects of electrolytes were investigated on the removal efficiency when several different electrolytes were used to change the electrode reaction in an electrokinetic (EK)-Fenton process to remediate phenanthrene-contaminated soil. Electrical potential gradient decreased initially due to the ion entrance into soil and then increased due to the ion extraction from soil under the electric field. Accumulated electroosmotic flow was $NaCl>KH_2PO_4>MgSO_4$ at the same concentration because the ionic strength of $MgSO_4$ was the highest and $Mg(OH)_2$ formed near the cathode reservoir plugged up soil pore to inhibit water flow. When hydrogen peroxide was contained in electrolyte solution, removal efficiency increased by Fenton reaction. When NaCl was used as an electrolyte compound, chlorine ($Cl_2$) was generated at the anode and dissolved to form hypochlorous acid (HClO), which increased phenanthrene removal. Therefore, the electrode reaction of electrolyte in the anode reservoir as well as its transport into soil should be considered to improve removal efficiency of EK-Fenton process.

Two Cases of Inhalation Injury Caused by An Explosion of Two Different Chemical Disinfectants(Sodium Dichloroiso Cyanurate & Calcium Hypochlorite) in a Swimming Pool (수영장에서 소독제 분말 가스 폭발에 의한 흡입화상 2례)

  • Lee, Su Jin;Park, Eun Young;Kim, Mi Ran;Lee, Kon Hee;Kim, Kwang Nam
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.2
    • /
    • pp.198-202
    • /
    • 2003
  • Of all toxic inhalant exposures, chlorine is one of the most common toxic chemical inhalants. When acutely inhaled, it can be responsible for symptoms ranging from upper air way irritation to more serious respiratory effects. It can also deteriorate lung function and lead to death. Chlorine and its compounds such as chlorinated cyanurates and hypochlorites are commonly used in water disinfection. The chemical agents discussed in this article are sodium dichloroiso cyanurate and calcium hypochlorite which are the two most popular products for swimming pool chlorination. They are both strong oxidizing agents which are soluble in water. Between the above two alkali agents, acid-base interaction occurred and generated heat. And the acid drove the combination of hypochlorous and chloride ions to form chlorine gas. We have experienced, two boys who had inhalation injuries caused by an accidental explosion which occurred in a swimming pool by mixing two different chlorinating agents : sodium dichloroiso cyanurate and calcium hypochlorite. The children suffered from respiratory difficulties after the exposure. They both required intensive care management and one needed the support of mechanical ventilation.