• Title/Summary/Keyword: Hydrogen permeation membrane

Search Result 97, Processing Time 0.026 seconds

Improved Microstructural Homogeneity of Ni-BCY Cermets Membrane via High-Energy Milling (고에너지 밀링을 통한 Ni-BaCe0.9Y0.1O3-δ 서멧 멤브레인의 미세구조 균질성 향상)

  • Kim, Hyejin;Ahn, Kiyong;Kim, Boyoung;Lee, Jongheun;Chung, Yong-Chae;Kim, Hae-Ryoung;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.648-653
    • /
    • 2012
  • Hybridization of dense ceramic membranes for hydrogen separation with an electronically conductive metallic phase is normally utilized to enhance the hydrogen permeation flux and thereby to increase the production efficiency of hydrogen. In this study, we developed a nickel and proton conducting oxide ($BaCe_{0.9}Y_{0.1}O_{3-{\delta}}$: BCY) based cermet (ceramic-metal composites) membrane. Focused on the general criteria in that the hydrogen permeation properties of a cermet membrane depend on its microstructural features, such as the grain size and the homogeneity of the mix, we tried to optimize the microstructure of Ni-BCY cermets by controlling the fabrication condition. The Ni-BCY composite powder was synthesized via a solid-state reaction using $2NiCO_3{\cdot}3Ni(OH)_2{\cdot}4H_2O$, $BaCeO_3$, $CeO_2$ and $Y_2O_3$ as a starting material. To optimize the mixing scale and homogeneity of the composite powder, we employed a high-energy milling process. With this high-energy milled composite powder, we could fabricate a fine-grained dense membrane with an excellent level of mixing homogeneity. This controlled Ni-BCY cermet membrane showed higher hydrogen permeability compared to uncontrolled Ni-BCY cermets created with a conventionally ball-milled composite powder.

Hydrogen Production Using Membrane Reactors

  • Giuseppe Barbieri;Paola Bernardo;Enrico Drioli;Lee, Dong-Wook;Sea, Bong-Kuk;Lee, Kew-Ho
    • Korean Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.68-74
    • /
    • 2003
  • Methane steam reforming (MSR) reaction for hydrogen production was studied in a membrane reactor (MR) using two tubular membranes, one Pd-based and one of porous alumina. A higher methane conversion than the thermodynamic equilibrium for a traditional reactor (TR) was achieved using MRs. The experimental temperature range was 350-500$^{\circ}C$; no sweep-gas was employed during reaction tests to avoid its back-permeation through the membrane and the steam/methane molar feed ratio (m) varied in the range 3.5-5.9. The best results (the difference between the MR conversion and the thermodynamic equilibrium was of about 7%) were achieved with the alumina membrane, working with the highest steam/methane ratio and at 450$^{\circ}C$. Silica membranes prepared at KRICT laboratories were characterized with permeation tests on single gases (N$_2$, H$_2$ and CH$_4$). These membranes are suited for H$_2$ separation at high temperature.

Hydrogen Permeation of ZnO-SiC Membranes Encapsulated with SiO2

  • Choi, Hyunji;Hwang, Hyeyoun;Jung, Miewon
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.6
    • /
    • pp.566-569
    • /
    • 2014
  • ZnO and SiC powders were fabricated to make crack-free composite membranes. Parts of some membranes were re-treated with an encapsulation process. These membranes were characterized by XRD, BET, and FE-SEM analyzes. The hydrogen permeation fluxes of the encapsulated and heat-treated membranes after encapsulation were observed using Sievert's type equipment. Values were measured at 1 bar with increasing temperatures. The obtained values of encapsulated and further heat-treated membrane at 298 K were $4.20{\times}10^{-6}$ and $8.64{\times}10^{-5}mol/m^2sPa$, respectively.

Ceramic barrier coated Pd hydrogen membrane on a porous nickel support (수소 분리용 팔라듐계 분리막의 세라믹 코팅 영향)

  • Lee, Chun-Boo;Lee, Sung-Wook;Park, Jin-Woo;Kim, Kwang-Ho;Hwang, Kyung-Ran;Park, Jong-Soo;Kim, Sung-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.114.1-114.1
    • /
    • 2010
  • A highly performed Pd-based hydrogen membrane has prepared successfully on a modified porous nickel support. The porous nickel support modified by impregnation method of $Al(NO_3)_3{\cdot}9H_2O$ (Aldrich Co.) over the nickel powder showed a strong resistance to hydrogen embrittlement and thermal stability. Plasma surface modification treatment was introduced as a pre-treatment process instead of conventional HCl wet activation. Ceramic barrier was coated on the external surface of the prepared nickel supports to prevent intermetallic diffusion and to enhance the affinity between the support and membrane. Palladium and copper were deposited at thicknesses of $4\mu}m$ and $0.5{\mu}m$, respectively, on a barrier-coated support by DC sputtering process. The permeation measurement was performed in pure hydrogen at $400^{\circ}C$. The single gas permeation of our membrane was two times higher than that of the previous membrane which do not have ceramic barrier.

  • PDF

Permeation behavior of olefin/nitrogen/hydrogen through PDMS dense and composite membranes

  • Choi, Seung-Hak;Kim, Jeong-Hoon;Shin, Hyo-Jin;Park, In-Jun;Roh, Jae-Sung;Kang, Deuk-Joo;Lee, Soo-Bok
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.137-138
    • /
    • 2003
  • The worldwide annual production of polyolefins amounted to 60 million tons in 2000. During the process, 1-2 wt% of the olefin monomers have been emitted and flared into the air, causing the huge energy consumption and severe carbon dioxide emission. Recently, membrane process has been proved to be the most competitive among other separation processes in terms of cost of equipments, energy consumption and safety in this application. The performance of membrane process highly depends on the membrane properties and thus, it is very important to develop good membrane materials and composite membranes. We prepared PMDS dense and composite membranes and studied basic permeation behaviors of a series of olefins(ethylene, propylene, 1 -butylene), nitrogen and hydrogen as model gases.

  • PDF

Hydrogen Permeation Properties of Ni-based Amorphous Alloys Membrane (Ni-based 비정질 합금막의 수소투과 특성)

  • Seok, Song;Lee, Dock-Young;Kim, Yoon-Bae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • Ni-based amorphous alloy ribbon was prepared by a single-roller melt-spinning technique. Palladium coating was found to enhance significantly the absorption/desorption behavior of hydrogen in amorphous alloy. The hydrogen permeability of a Pd-coated $(Ni_{60}Nb_{40}){_{100-X}}$TaX(x=5, 10) amorphous alloy was examined in the temperature range of $623{\sim}773K$, comparable with those of $Pd_{60}-Cu_{40}$ alloys. The permeated hydrogen flux was increased with increasing the temperature and the difference of hydrogen pressure between the feed side and permeates side of the membrane. The Ni-based amorphous alloys were characterized by X-ray diffractometry(XRD) and differential scanning calorimetry(DSC). The morphology of surface and roughness was observed by using scanning electron microscopy(SEM) and atomic force microscopy(AFM).

Hydrogen Permeation Performance of Pd, Pd/Cu Membranes Manufactured through Electroless Plating (무전해 도금을 이용해 제작한 Pd, Pd/Cu 분리막의 수소 투과 성능)

  • Jeong In, Lee;Min Chang, Shin;Xuelong, Zhuang;Jae Yeon, Hwang;Chang-Hun, Jeong;Jung Hoon, Park
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.456-464
    • /
    • 2022
  • Hydrogen permeation performance was analyzed by manufacturing Pd and Pd-Cu membranes through electroless plating. As a support for the Pd and Pd-Cu membranes, α-Al2O3 ceramic hollow fiber were used. Pd-Cu membrane was manufactured through sequential electroless plating, and then annealing was performed at 500°C, for 18 h in a hydrogen atmosphere to make Pd and Cu alloy. After annealing, the Pd-Cu membrane confirmed that the alloy was formed through EDS (Energy Dispersive X-ray Spectroscopy) and XRD (X-ray Diffraction) analysis. In addition, the thickness of the Pd and Pd-Cu plating layers were measured to be about 3.21 and 3.72 µm, respectively, through SEM (Scanning Electron Microscope) analysis. Hydrogen permeation performance was tested for hydrogen permeation in the range of 350~450°C and 1~4 bar in hydrogen single gas and mixed gas (H2, N2). In a single hydrogen gas, Pd and Pd-Cu membranes have flux of up to 54.42 and 67.17 ml/cm2⋅ min at 450 °C and 4 bar. In the mixed gas, it was confirmed that the separation factors of 1308 and 453 were obtained under the conditions of 450 °C and 4 bar.

Improvement of the Thermochemical water-splitting IS Process Using the Membrane Technology (분리막 기술을 이용한 열화학적 수소제조 IS[요오드-황] 프로세스의 개선)

  • Hwang, Gab-Jin;Kim, Jong-Won;Sim, Kyu-Sung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.3
    • /
    • pp.249-258
    • /
    • 2002
  • Thermochemical water-splitting IS(Iodine-Sulfur) process has been investigating for large-scale hydrogen production. For the construction of an efficient process scheme, two kinds of membrane technologies are under investigating to improve the hydrogen producing HI decomposition step. One is a concentration of HI in quasi-azeotropic HIx ($HI-H_2O-I_2$) solution by elecro-electrodialysis. It was confirmed that HI concentrated from the $HI-H_2O-I_2$ solution with a molar ratio of 1:5:1 at $80^{\circ}C$. The other is a membrane reactor to enhance the one-pass conversion of thermal decomposition reaction of gaseous hydrogen iodide (HI). It was found from the simulation study that the conversion of over 0.9 would be attainable using the membrane reactor using the gas permeation properties of the prepared silica hydrogen permselective membrane by chemical vapor deposition (CVD). Design criterion of the membrane reactor was also discussed.

Properties of Synthesized Al2O3-CuO-ZnO/Ni Composite for Hydrogen Membranes

  • Rim, Saetbyol;Jung, Miewon
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.477-480
    • /
    • 2014
  • An $Al_2O_3$-CuO-ZnO (ACZ) precursor powder was synthesized by a facial sol-gel process using a nonionic surfactant span 80 as the chelating agent to improve the surface area and morphology. When creating a hydrogen membrane, several kinds of properties are required, such as easy dissociation of hydrogen molecules, fast hydrogen diffusion, high hydrogen solubility, and resistance to hydrogen embrittlement. ACZ-Ni composite membranes (cermet) were prepared with this precursor and pure Ni powder via the hot press sintering (HPS) method. The ACZ powder was characterized by XRD, BET, and FE-SEM. Hydrogen permeation experiments were performed by Sievert's type of hydrogen permeation membrane equipment. The hydrogen permeability of ACZ/Ni 10 wt% and ACZ/Ni 20 wt% was obtained as 7.2 and $10molm^{-2}s^{-1}$ at RT, respectively. These values of the corresponding membranes were slightly increased with increasing pressures.

Hydrogen Isotopes Recovery Using Pd Membrane and Process Simulation (Pd 분리막을 이용한 수소동위원소 회수 실험과 공정 시뮬레이션)

  • JUNG, WOO-CHAN;PARK, JONG-HWAN;HAN, SANG-WOO;JANG, MIN-HO;LEE, HYEON-GON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.219-227
    • /
    • 2021
  • Hydrogen isotopes, which are used as raw materials in fusion reaction, participate in the reaction only in small amount, and most of them are released together with impurities. In order to recover and reuse only hydrogen isotopes from this exhaust gas, a recovery process is required, and most of the hydrogen isotopes can be recovered using a Pd Membrane. In this study, the recovery rate of hydrogen isotopes was measured through the first and second stage Pd membrane experiments. In the case of the experiment using a single stage Pd membrane, about 99.2%, and in the case of the first stage and second stage Pd membrane connection experiments, a recovery rate of 99.9% or more was obtained. Therefore, the recovery rate of Pd membrane process applied to hydrogen can be applied to hydrogen isotopes. In addition, the simulation model was established using aspen custom modeler, a commercial software, and the validity of the simulation was checked by applying the references and experimental data. The simulation results based on the experimental data showed a difference of 2% or less.