• Title/Summary/Keyword: Hydrogen mole fraction

Search Result 39, Processing Time 0.02 seconds

The Effect of N2 Dilution on the Flame Stabilization in a Non-Premixed Turbulent H2 Jet with Coaxial Air (질소 희석이 수소 난류확산화염의 화염안정성에 미치는 영향)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.477-485
    • /
    • 2009
  • The study of nitrogen dilution effect on the flame stability was experimentally investigated in a non-premixed turbulent lifted hydrogen jet with coaxial air. Hydrogen gas was used as a fuel and coaxial air was used to make flame liftoff. Each of hydrogen and air were injected through axisymetric inner and outer nozzles ($d_F=3.65\;mm$ and $d_A=14.1\;mm$). And both fuel jet and coaxial air velocity were fixed as $u_F=200\;m/s$ and $u_A=16\;m/s$, while the mole fraction of nitrogen diluents gas was varied from 0.0 to 0.2 with 0.1 step. For the analysis of flame structure and the flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF laser diagnostics had been performed. The stabilization point was selected in the most upstream region of the flame base and defined as the point where the turbulent flame propagation velocity was equal to the axial component of local flow velocity. We found that the turbulent flame propagation velocity increased with the decrease of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity and axial strain rate, even though nitrogen diluents mole fraction was changed.

Nitrogen Dilution Effects on Liftoff Flame Stability in Non-premixed Turbulent Hydrogen Jet with Coaxial Air (질소희석이 부상된 수소 난류확산화염의 화염안정성에 미치는 영향)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.393-396
    • /
    • 2008
  • The study of nitrogen dilution effect on flame stability was experimentally investigated in non-premixed turbulent lifted hydrogen jet with coaxial air. hydrogen gas was used as a fuel and coaxial air was injected to make flame liftoff. And both of the fuel jet and coaxial air velocity were fixed as $u_F$=200 m/s and $u_A$=16 m/s, while nitrogen diluents mole fraction was varied from 0 to 0.2. For the analysis of flame structure and flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF had been performed. It was found that the turbulent flame propagation velocity increased as decreasing of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity, even though the mole fraction of nitrogen diluents gas was changed.

  • PDF

Molecular Conformation-Dependent Complexation between Acidic- and Basic-Polypeptides via Hydrogen Bonding in Solution

  • Jang, Cheon Hak;Kim, Hyeon Don;Jo, Byeong Gi;Lee, Jang U
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.42-47
    • /
    • 1995
  • Interpolymer complex formation between basic polypeptide poly(L-proline) Form Ⅱ (PLP(Ⅱ)) and acidic polypeptides poly(L-glutamic acid) (PLGA) and poly(L-aspartic acid)(PLAA) has been studied in water-methanol (1:2 v/v) mixed-solvent by viscometry, potentiometry, light scattering and circular dichroism (CD) measurements. It has been found that polymer complexes between PLP(Ⅱ) and PLGA (or PLAA) are formed via hydrogen bonding with a stoichiometric ratio of PLP(Ⅱ)/PLGA (or PLAA)=1:2 (in unit mole ratio) and that PLP(Ⅱ) forms polymer complex more favorably with PLGA than with PLAA. In addition, the minimum (for pH 5.0) and the maximum (for pH 3.2) in reduced viscosity of dilute PLP(Ⅱ)-PLGA mixed solutions are observed at 0.67 unit mole fraction of PLGA (i.e., [PLP(Ⅱ)]/[PLGA]=1/2). These findings could be explained in terms of molecular structure (or conformation) of the complementary polymers associated with the complex formation.

An Experimental Study on the Combustion Characteristics with Hydrogen Enrichment in a Dump Combustor (수소 혼합에 따른 덤프 연소기내의 연소 특성에 관한 실험적 연구)

  • Kim, Dae-Hee;Hong, Jung-Goo;Shin, Hyun-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2977-2983
    • /
    • 2008
  • The combustion characteristics of a partially premixed flame in a dump combustor were studied to determine the effects of hydrogen enrichment in propane. Bluff-body was used for flame stabilization. Fuel mixtures containing a hydrogen mole fraction ranging from 0.1 to 0.5 were burnt at ambient pressure within a quartz chamber. Tests were carried out keeping the total reactant flow rate by adjusting the fuel and air flow rates. The fluctuations of pressure were measured by piezoelectric pressure sensor. The instantaneous flame structure and OH chemiluminescence images were described by High-speed Intensified Charged Coupled Device (HICCD) camera and Intensified Charged Coupled Device (ICCD) camera. The present results show that hydrogen enrichment in fuel changed the location of primary reaction zone from inner recirculation zone to turbulent shear layer and pressure signal. The reason is that chemical aspects take precedence over flow aspects in the hydrogen-enriched flame.

  • PDF

A CFD Study on Unsteady and Steady State of the Hydrogen Leakage for Residential Fuel Cell System (가정용 연료전지 시스템 내부 수소 누출의 비정상 및 정상 상태에 관한 전산 해석)

  • Chung, Tae-Yong;Ahn, Jae-Uk;Nam, Jin-Hyun;Shin, Dong-Hoon;Kim, Young-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.41-46
    • /
    • 2007
  • The residential fuel cell system was modeled as a box-shaped chamber with vent openings, filled with various components such as reformer, desulfurizer, fuel cell stack and humidifier. When the vent openings are 1% of the total surface and hydrogen leakage 1%, hydrogen concentration is around 0.1% higher than the other regions from leak points in the chamber at 30 seconds and hydrogen concentration is increased from 0.3% to 0.7% in the upper region of the system after 200 seconds. When the vent openings are 1% of the total surface and hydrogen leakage 1%, 3%, 5%, the steady state result of CFD, 5% of hydrogen leakage is reached the lowest ignition limit in the system. When the vent openings are 2% of the total surface and hydrogen leakage 1%, hydrogen concentration is increased in the bottom of the system for 60 seconds. After 250 seconds, hydrogen concentration is reached the steady state in the system. As the vent opening of the total surface increased from 1% to 2%, averaged hydrogen mole fraction is under 1% in the system, however, upper regions of the system from the hydrogen leakage points are shown over 1% of hydrogen mole fraction.

  • PDF

Numerical Study on the Effect of Area Changes in Air Inlets and Vent Ports on the Ventilation of Leaking Hydrogen (급·배기구 면적 변화가 누출 수소 환기에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.385-393
    • /
    • 2022
  • Hydrogen has reduced greenhouse gas (GHG) emissions, the main cause of global warming, and is emerging as an eco-friendly energy source for ships. Hydrogen is a substance with a lower flammability limit (LFL) of 4 to 75% and a high risk of explosion. To be used for ships, it must be sufficiently safe against leaks. In this study, we analyzed the effect of changes in the area of the air inlet / vent port on the ventilation performance when hydrogen leaks occur in the hydrogen tank storage room. The area of the air inlet / vent port is 1A = 740 mm × 740 mm, and the size and position can be easily changed on the surface of the storage chamber. Using ANSYS CFX ver 18.1, which is a CFD commercial software, the area of the air inlet / vent port was changed to 1A, 2A, 3A, and 5A, and the hydrogen mole fraction in the storage chamber when the area changed was analyzed. Consequently, the increase in the area of the air inlet port further reduced the concentration of the leaked hydrogen as compared with that of the vent port, and improved the ventilation performance of at least 2A or more from the single air inlet port. As the area of the air inlet port increased, hydrogen was uniformly stratified at the upper part of the storage chamber, but was out of the LFL range. However, simply increasing the area of the vent port inadequately affected the ventilation performance.

A CFD Study on the Hydrogen Leakage for Residential Fuel cell System (가정용 연료전지 시스템 내부의 수소 누출에 관한 전산해석)

  • Ahn, Jae-Uk;Chung, Tae-Yong;Shin, Dong-Hoon;Nam, Jin-Hyun;Kim, Young-Gyu;Park, Ju-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2026-2031
    • /
    • 2007
  • Hydrogen is receiving much research attention as an alternative substitute for hydrocarbon fuels these days due to its cleanliness and renewability. However, hydrogen should be used with caution because of its high propensity for leak and wide flammable range. This study deals with a situation that hydrogen leaks and then forms a flammable mixture inside 1kW class residential fuel cell. The residential fuel cell was modeled as a box-shaped chamber with vent openings at the top and bottom, filled with various components such as reformer, desulfurizer, fuel cell stack and humidifier. Computational fluid dynamics (CFD) was used to simulate the diffusion, buoyant flow and accumulation of leaked hydrogen in the modeled chamber. From the simulation, the risk region vulnerable to flame was identified and the methods to minimize such hazardous region was discussed. When the vent openings are 1% of the total surface, as the quantity of hydrogen leakage increases the risk regions increases accordingly. As the vent openings of the total surface increased from 1% to 2.3%, averaged hydrogen mole fraction is under 1% in the system.

  • PDF

Complex Formation of Syndiotactic Poly(methacrylic acid) with Complementary Polymers through Hydrogen Bonding

  • Kim, Bum-Sung;Jeon, Seung-Ho;Ree, Tai-Kyue
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.238-240
    • /
    • 1986
  • Complex formations between syndiotactic poly(methacrylic acid) (st-PMAA) and poly(N-vinyl pyrrolidone) (PVP), and that between st-PMAA and polyethyleneoxide (PEO) through hydrogen bonding were studied by viscometry and potentiometry. Reduced viscosity (${\eta}_{red}$) was measured at various mole fraction of PVP or PEO with respect to a constant amount of st-PMAA. Observation shows a sharp minimum at the 1:1 mole ratio of st-PMAA:PVP or st-PMAA:PEO, which shows that the complexation becomes optimal and the complex has a compact structure in this ratio. Variation of pH also supports this conclusion. This is the case of the system of st-PMAA and PVP in water as well as in DMF. Also the complexation is much enhanced when the molecular weight of PVP is high. Meanwhile, the system of st-PMAA and PEO shows a little different behavior, i.e., this system does not form the complex in DMF and does only in water. It is because the interaction st-PMAA with PEO is weaker than that with PVP.

Simulation of the Hydrogen Conversion Rate Prediction for a Solar Chemical Reactor (태양열 화학반응기의 수소전환효율 예측 시뮬레이션)

  • Ko, Jo-Han;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.294-299
    • /
    • 2008
  • Steam reforming of methane is the most wide spread method for hydrogen production. It has heed studied more than 60 years. methane reforming has advantages in technological maturity and economical production cost. Using a high-temperature solar thermal energy is an advanced technology in Steam reforming process. The synthesis gas, the product of the reforming process, can be applied directly for a combined cycle or separated for a hydrogen. In this paper, hydrogen conversion rate of a solar chemical reactor is calculated using commercial CFD program. 2 models are considered. Model-1 is original model which is designed from the former researches. And model-2 is ring-disk set of baffle is inserted to enhance the performance. The solar chemical reactor has 3 inlet nozzle at the bottom of the side wall near quartz glass and an exit is located at the top. Methane and steam is premixed with 50:50 mole fraction and goes into the inside. Passing through the porous media, the reactants are conversed into hydrogen and carbon monoxide.

  • PDF

CFD Simulation of Pd-Ag Membrane Process for $CO_2$ Separation (이산화탄소 분리를 위한 Pd-Ag 분리막 공정의 CFD 모사)

  • Oh, Min;Park, Junyong;Noh, Seunghyo;Hong, Seong Uk
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.104-108
    • /
    • 2009
  • In this study, for the flow of carbon dioxide/hydrogen mixture through a tubular type Pd-Ag membrane, hydrogen partial pressure, velocity profile, and concentration profile were simulated as a function of inlet flow rate using computational fluid dynamics (CFD) technique. The simulation results indicated that the mole fraction of carbon dioxide increased slowly in the longitudinal direction as the flow rate increased. In addition, the effects of inlet flow rate and the length of membrane on hydrogen recovery were investigated. At lower flow rate and for longer membrane, the hydrogen recovery was larger.