• Title/Summary/Keyword: Hydrogen ion

Search Result 759, Processing Time 0.028 seconds

The design and fabricationt for ion fraction measurement of plasma generator (플라즈마발생기의 이온분율 측정 장치 설계 및 제작)

  • Lee, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

$CO_2$ Buffering and Hydrogen Ion Concentration Gradient across Cell Membrane in Acute Acid-Base Disturbances in Dogs (혈액과 조직의 $CO_2$완충능 및 세포막을 통한 $H^+$농도 경사)

  • Hwang, Sang-Ik;Park, Young-Bae;Min, Byoung-Ku;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.17 no.2
    • /
    • pp.119-124
    • /
    • 1983
  • The in vivo and in vitro buffer capacities of true plasma and tissue buffer capaciies were compared on dogs. Intracellular pH was determined on skeletal muscle by a modification of the method of Schloerb and Grantham using $C^{14}$ DMO. The in vivo curve for plasma or extracellular fluid has a much lower slope than the in vitro curve. The in vivo slope of skeletal muscle in the dog is approximately 20 sl. The slope for skeletal muscle in vivo falls between the in vitro and in vivo slopes of true plasma. It appears that intracellular hydrogen ion varies linearly with extracellular hydrogen ion when $CO_2$ tension is changed. Both hydrogen ion gradient and Hi/He ratio vary in skeletal muscle, with an increase in $CO_2$ tension. Infusion of 0.3N HCl gave two distinct patterns, the $H_i-H_e$ gradient decreased; and it would appear that very little hydrogen ion as such penetrated to the inside of the cells during the time of observation. Although lactic acid presumably enters the cell and the same of larger load was given as was used for hydrochloric acid, only very mild intracellular acidosis resulted, ostensibly due to metabolism of this substrate. Gluconic acid produced a more severe acidosis, both intracellularly and extracellularly, but with both of these acids the hydrogen ion gradient decreased and the $H_i/H_e$ ratio also decreased. The experiments on the dogs with hemorrhagic shock the hydrogen ion increase producing the acidosis originates inside the cells. Even so, the hydrogen ion gradient increased only very slightly in the acute experiments. This may suggest that even over short intervals of time skeletal muscle cells have a capacity to pump out hydrogen ions at a rate which maintains approximately the normal $H_i/H_e$ gradient when the source of the hydrogen ion is in the interior of the cell.

  • PDF

Degradation of herbicide paraquat by Fenton reagent and UV light irradiation (Fenton 시약 및 UV 광 조사에 의한 제초제 paraquat의 분해)

  • Kim, Byung-Ha;Ahn, Mi-Youn;Kim, Jang-Eok
    • The Korean Journal of Pesticide Science
    • /
    • v.3 no.3
    • /
    • pp.20-26
    • /
    • 1999
  • This study was to investigate the potential degradation of a herbicide paraquat by Fenton reagents(ferric ion and hydrogen peroxide) under UV light irradiation(365 nm) in an aqueous solution. When $10{\sim}500$ mg/L of paraquat was reacted with either ferric ion or hydrogen peroxide in the dark or under UV light, no degradation was occurred. However, the simultaneous application of both ferric ion(0.8 mM) and hydrogen peroxide(0.140 M) in paraquat solution(500 mg/L) caused dramatic degradation of paraquat both in the dark (approximately 78%) and under UV light(approximately 90%). The reaction approached an equilibrium state in 10 hours. In the dark, when $0.2{\sim}0.8$ mM ferric ion was added, $20{\sim}70%$ paraquat of $10{\sim}500$ mg/L was degraded, regardless of hydrogen peroxide concentrations($0.035{\sim}0.140$ M), while under UV light, 95% of 10 and 100 mg/L paraquat was degraded regardless of ferric ion and hydrogen peroxide concentrations. At paraquat concentration of 200 and 500 mg/L, paraquat degradation increased with increasing ferric ion concentrations as in the dark. However the increase in hydrogen peroxide concentration did not affect the extent of paraquat degradation. The initial reaction rate constants(k) for paraquat degradation ranged from 0.0004 to 0.0314, and 0.0023 to 0.0367 in the dark and under UV light, respectively. The initial reaction rate constant increased in proportion to the increase in ferric ion concentration in both conditions. The half-lives of paraquat degradation(t1/2) were 20 - 1,980 and 19 - 303 minutes in the dark and under UV light, respectively. This study indicates that Fenton reagents under UV light irradiation are more potent than in the dark in terms of herbicide paraquat degradation in an aqueous solution.

  • PDF

The Effect of Hydrogen Peroxide-Treated Metallothionein on the Hepatic Xanthine Oxidase Activity

  • Huh, Keun;Shin, Uk-Seob;Lee, Sang-Il
    • BMB Reports
    • /
    • v.28 no.6
    • /
    • pp.490-493
    • /
    • 1995
  • We investigated the effect of hydrogen peroxide-treated metallothionein on the hepatic xanthine oxidase activity in vitro. When the metallothionein was preincubated with 1 mM of hydrogen peroxide, the activity of xanthine oxidase and type conversion were elevated dose-dependently by the addition of metallothionein into the reaction mixture. While increasing the treatment of hydrogen peroxide to the $50{\mu}g$of metallothionein, the xanthine oxidase activity and type conversion ratio were remarkably elevated dose dependently compared to the control. When cadmium ion was added to the reaction mixture, the increasing pattern of the enzyme activity was similar to the effect of hydrogen peroxide-treated metallothionein. DTT or penicillamine restored the increasing activity and type conversion of xanthine oxidase by the cadmium ion to the control level.

  • PDF

Surface Modification of Polytetrafluoroethylene by 1 keV Argon and Hydrogen Irradiated in Nitrogen and Ammonia Gas Environment (질소와 암모니아 존재하에서 1 keV 에너지의 알곤과 수소 이온 조사에 의한 PTFE(polytetrafluoroethylene)의 표면형상 변화연구)

  • Yeu, Dae-Hwan;Kim, Ki-Hwan;Kang, Dong-Yeob;Kim, Joong-Soo;Koh, Seok-Keun;Kim, Hyun-Joo
    • Korean Journal of Materials Research
    • /
    • v.16 no.6
    • /
    • pp.367-372
    • /
    • 2006
  • Polytetrafluoroethylene (PTFE) surface was modified for improving hydrophilicity by ion irradiation in environmental gas of $N_2$ and $NH_3$, respectively. The water contact angle onto the PTFE surface increased from $104{\circ}$ to over $140{\circ}$ by Ar ion irradiation in $N_2$ gas. In the case of $NH_3$ as environmental gas, there were a slight increase of contact angle from ion dose of $1{\times}10^{15}\;to\;5{\times}10^{15}\;ions/cm^2$, and its dramatic decrease to the value of 35o at the conditions of ion dose higher than $1{\times}10^{16}\;ions/cm^2$. It was found from SEM results that the surface morphology of PTFE was changed into one with filament structure after Ar ion irradiation in $N_2$ gas environments. On the contrary, Ar ion irradiation in $NH_3$ gas condition induced the PTFE surface with network structure. Hydrogen ion irradiation resulted in a little change of PTFE surface morphology, comparing with the case of Ar ion irradiation. The water contact angle of hydrogen ion irradiated PTFE surface in reactive gas decreased with increment of ion dose. Hydrogen ion irradiation could improve hydrophilicity with little change of surface morphology. It might be considered from FT-IR results that the improvement in wettability of PTFE surface by ion irradiation in $N_2$ and $NH_3$ gases could be due to the hydrophilic groups of NHx bonds.

Characteristics of a Titanium-oxide Layer Prepared by Plasma Electrolytic Oxidation for Hydrogen-ion Sensing

  • Lee, Do Kyung;Hwang, Deok Rok;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.76-80
    • /
    • 2019
  • The characteristics of a titanium oxide layer prepared using a plasma electrolytic oxidation (PEO) process were investigated, using an extended gate ion sensitive field effect transistor (EG-ISFET) to confirm the layer's capability to react with hydrogen ions. The surface morphology and element distribution of the PEO-processed titanium oxide were observed and analyzed using field-emission scanning-electron microscopy (FE-SEM) and energy-distribution spectroscopy (EDS). The titanium oxide prepared by the PEO process was utilized as a hydrogen-ion sensing membrane and an extended gate insulator. A commercially available n-channel enhancement MOS-FET (metal-oxide-semiconductor FET) played a role as a transducer. The responses of the PEO-processed titanium oxide to different pH solutions were analyzed. The output drain current was linearly related to the pH solutions in the range of pH 4 to pH 12. It was confirmed that the titanium-oxide layer prepared by the PEO process could feasibly be used as a hydrogen-ion-sensing membrane for EGFET measurements.

Electrochemical behavior of dissolved hydrogen at Pt electrode surface in a high temperature LiOH-H3BO3 solution: Effect of chloride ion on the transient current of the dissolved hydrogen

  • Myung-Hee Yun;Jei-Won Yeon
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3659-3664
    • /
    • 2023
  • The electrochemical behavior of dissolved hydrogen (H2) was investigated at a Pt electrode in a high temperature LiOH-H3BO3 solution. The diffusion current of the H2 oxidation was proportional to the concentration of the dissolved H2 as well as the reciprocal of the temperature. In the polarization curve, a potential region in which the oxidation current decreases despite an increase in the applied potential between the H2 oxidation and the water oxidation regions was observed. This potential region was interpreted as being caused by the formation of a Pt oxide layer. Using the properties of the Cl- ion that reduces the growth rate of the Pt oxide layer, it was confirmed that there is a correlation between the Cl- ion concentration and the transient current of the H2 oxidation.

Current characteristics of Cu/NaCl electrolyte/Zn electrochemical cell (구리/NaCl 전해질/아연 전기화학전지의 전류특성)

  • Kim, Yong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1626-1631
    • /
    • 2010
  • The characteristics of electric current for the voltaic cell are important for electric power applications. In this paper, an electrical equivalent model consist of three resisters and a capacitance for the Cu/NaCl solution/Zn electrochemical cell is proposed. The capacitance which exists in the Zn electrode/electrolytic interface increased according to Zn electrode area, but cannot affect almost in electric current. Complex impedance plot was used to analysis the interface effect for Zn/electrolyte. This result shows that the interface is similar with the electric transmission line. The short current measurements were conducted to investigate the effects of hydrogen peroxide, the watery sulfuric acid and NaCl aqueous solution. As the hydrogen peroxide increased, the electric current increased because the hydrogen gas being converted with the water. Also electric current increased significantly with increase of the hydrogen ion with the watery sulfuric acid and increased with increase of $Na^+$ ion and $Cl^-$ion in the NaCl electrolyte.

Lithium Recovery from NCM Lithium Ion Battery by Hydrogen Reduction Followed by Water Leaching (NCM계 리튬이온 배터리 양극재의 수소환원과 수침출에 의한 리튬 회수)

  • So-Yeong Lee;So-Yeon Lee;Dae-Hyeon Lee;Ho-Sang Sohn
    • Resources Recycling
    • /
    • v.33 no.1
    • /
    • pp.15-21
    • /
    • 2024
  • The demand for electric vehicles powered by lithium-ion batteries is continuously increasing. Recovery of valuable metals from waste lithium-ion batteries will be necessary in the future. This research investigated the effect of reaction temperature on the lithium recovery ratio from hydrogen reduction followed by water leaching from lithium-ion battery NCM-based cathode materials. As the reaction temperature increased, the weight loss ratio observed after initiation increased rapidly owing to hydrogen reduction of NiO and CoO; at the same time, the H2O amount generated increased. Above 602 ℃, the anode materials Ni and Co were reduced and existed in the metallic phases. As the hydrogen reduction temperature was increased, the Li recovery ratio also increased; at 704 ℃ and above, the Li recovery ratio reached a maximum of approximately 92%. Therefore, it is expected that Li can be selectively recovered by hydrogen reduction as a waste lithium-ion battery pretreatment, and the residue can be reprocessed to efficiently separate and recover valuable metals.

The Kinetics and Mechanism of Nucleophilic Addition of Hydrogen Cyanide to $ {\alpha}$-Cyano-$ {\beta}$-piperonylacrylic Acid ($ {\alpha}$-Cyano-$ {\beta}$-Piperonylacrylic Acid에 대한 Hydrogen Cyanide의 친핵성 첨가반응에 관한 연구)

  • Ki Sung Kwon;Tae Rin Kim
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.6
    • /
    • pp.423-429
    • /
    • 1974
  • The rate constant of the addition of hydrogen cyanide to $ ${\alpha}$-cyano-\beta-piperonylacrylic$ acid (CPA) were determined by UV spectrophotometry at various pH and a rate equation which can be applied over wide pH range was obtained. From this equation, one may conclude that below pH 3 the reaction is started by the addition of hydrogen cyanide molecule to CPA, however, at pH 6~8, hydrogen cyanide is added to $ {\alpha}$-cyano-$ {\beta}$-piperonyl acrylate anion. From pH 3 to 6, these two reaction are competitive. Above pH 9, the reaction is proceeded by the addition of cyanide ion to $ {\alpha}$-cyano-$ {\beta}$-piperonyl acrylate ion. From pH 3 to 9, the complex reaction mechanism can also be fully explained by the rate equation obtained.

  • PDF