• Title/Summary/Keyword: Hydrogen ion

Search Result 767, Processing Time 0.033 seconds

The Effects of cathodic protection on fracture toughness of buried gas pipeline (매설가스배관의 음극방식이 배관의 파괴인성에 미치는 영향)

  • Kim, Cheol-Man;Kim, Woo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.573-578
    • /
    • 2001
  • For the corrosion protect ion of the natural gas transmission pipelines, two methods are used, cathodic protection and coating technique. In the case of cathodic protection, defects are embrittled by occurring hydrogen at the crack tip or material surface. It is however very important to evaluate whether cracks in the embrittled area can grow or not, especially in weld metal. In this work, on the basis of elastic plastic fracture mechanics, we performed CTOD test ing with varying test conditions, such as the potential and current density. The CTOD of the base steel and weld metal showed a strong dependence of the test conditions. The CTOD decreased with increasing cathodic potential and current density. The morphology of the fracture surface showed quasi-cleavage. Hydrogen introduced fractures, caused by cathodic overprotection.

  • PDF

Electrochemical Anodic Formation of VO2 Nanotubes and Hydrogen Sorption Property

  • Lee, Hyeonkwon;Jung, Minji;Oh, Hyunchul;Lee, Kiyoung
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.212-216
    • /
    • 2021
  • We investigated the feasibility of hydrogen storage with electrochemically formed VO2 nanotubes. The VO2 nanotubes were fabricated through the anodization of vanadium metal in fluoride ion-containing organic electrolyte followed by an annealing process in an Ar-saturated atmosphere at 673 K for 3 h at a heating rate of 3 K /min. During anodization, the current density significantly increased up to 7.93 mA/cm2 for approximately 500 s owing to heat generation, which led to a fast-electrochemical etching reaction of the outermost part of the nanotubes. By controlling the anodization temperature, highly ordered VO2 nanotubes were grown on the metal substrate without using any binders or adhesives. Furthermore, we demonstrated the hydrogen sorption properties of the anodic VO2 nanotubes.

Enhanced ICRF Heating of H-mode Plasmas in KSTAR

  • Kim, Sun-Ho;Wang, Son-Jong;Ahn, Chan-Yong;Kim, Sung-Kyew
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.317-317
    • /
    • 2011
  • Enhanced ICRF (Ion Cyclotron Range of Frequency) ion heating of H-mode D(H) plasma will be tried in 2011 KSTAR experimental campaign. Minority heating is a main ion heating scheme in the ICRF. Its efficiency increases as the hydrogen minority ratio increases in deuterium plasmas. And it should be sustained at a lower level than the critical minority ratio. Consequently, it is important to elevate the critical ratio to maximize ion heating and it is possible by increasing the ion temperature or parallel wave number (k${\parallel}$) of the antenna. Increasing the k${\parallel}$ is not a good approach since the coupling efficiency decreases exponentially with regard to k${\parallel}$ as well. So the remaining method is to increase ion temperature by using NB (Neutral Beam). Ion heating fraction of NB increases as the electron temperature increases. Therefore, we will try to heat electron by using ECH together with NB ion heating before ICRF power injection. The ICRF heating efficiency will be compared with respect to several NB+ECH+ICRF heating combinations through several diagnostics such as XICS (Xray Imaging Crystal Spectroscopy), CES (Charge Exchange Spectroscopy) and neutron measurement. The theoretical background and the experimental results will be presented in more detail in the conference.

  • PDF

$H^-$ Stripping Simulation with a Magnet and $H^{\circ}$ Beam Extractor Design

  • Ahn, Hyo-Eun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.951-956
    • /
    • 1998
  • The beam extraction system for the KOMAC[1] (Korea Multi-purpose Accelerator Complex) project is to be designed to partially extract H ̄ beam at both 100 and 260 MeV This paper describes a simulation study of charge changing extraction with a stripper magnet and a possible design of a H$^{0}$ extractor by utilizing the simulation study The method consists of converting the negative hydrogen (H ̄) ion beam from the linac to a chosen intensity (0-100%) of neutral hydrogen (H$^{0}$ ) beam having an acceptable omittance and drifting it directly onto a stripper foil followed by a downstream beamline.

  • PDF

Influence of the C.T.I of phenolic resin (페놀수지의 C.T.I에 미치는 영향)

  • 이보호;박동화;정인성
    • Electrical & Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.70-77
    • /
    • 1988
  • This paper describes the influence of the electrode materials, moisture content, electrolyte density, temperature, surface state, ion absorbent on the C.T.I of phenolic resin by the I.E,C, 112 method. C.T.I are increased for electrode materials with low hydrogen overvoltage and high soluble point. Increusing moisture content of samples increased by logarithmical on the droplet number to tracking breakdown. Increasing electrolyte temperature region above 70-80(.deg.C) decreased hydrogen over-voltage, following the density changes are decreased by C.T.I=1/aD$^{2}$-bD+C.

  • PDF

Hydrogen ion-selective membrane electrodes based on tetrabenzylalkylenediamine (Tetrabenzylalkylenediamine을 이용한 수소이온 선택성 막전극)

  • Kim, Jae-Woo;Cho, Dong-Hoe;Jeong, Seong-Suk;Chung, Koo-Chun;Park, Myon-Yong
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.161-167
    • /
    • 1997
  • This is on hydrogen ion-selective memebrane electrodes which were made of tetrabenzylmethylenediamine (TBMDA), tetrabenzylethylenediamine (TBEDA), tetrabenzylpropylenediamine(TBPDA) and tetrabenzylhexylenediamine(TBHDA) as neutral carriers. Their response potentials to carbon number between amino groups showed linear selectivities to hydrogen ion in the range of pH 1~pH 9, pH 2~pH 9, pH 3~pH 9 and pH 4~pH 9 and slopes were 48mV/pH, 52mV/pH, 64mV/pH, 59mV/pH respectively. The interferences effect on the cations were measured to alkali metal ions($Li^+$, $Na^+$, $K^+$), alkaline earth metal ions ($Mg^{2+}$, $Ca^{2+}$, $Sr^{2+}$, $Ba^{2+}$), transition metals ions($Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$) and anions($I^-$, $Br^-$, ${NO_3}^-$, $SCN^-$), and selectivity coefficients were measured by separate-solution method. The membrane electrode made of TBMDA among the electrodes showed the best selectivity in acidic solution.

  • PDF

Hydrogen ion-selective membrane electrodes based on arylamines as neutral carriers (아릴아민계의 중성운반체를 이용한 수소이온선택성 막전극)

  • Jeong, Seong-Suk;Cho, Dong-Hoe;Kim, Jae-Woo;Chung, Koo-Chun;Park, Myon-Yong
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.78-83
    • /
    • 1996
  • Hydrogen ion-selective membrane electrodes based on tribenzylamine(TBA), tetrabenzylethylenediamine(TBEDA), pentabenzyldiethylenetriamine(PBDETA) as neutral carriers were shown good selectivity and linearity in the range of pH 1~pH 9, pH 2~pH 12, pH 4~pH 12. The pH selectivity of this membrane electrodes have nothing relation with the numbers of unshared electron pair in TBA, TBEDA, PBDETA and were shown a slope of 43.8mV/pH, 46.9mV/pH, 43.6mV/pH respectively. The selectivity coefficients were determined by the separate solution method for alkali($Li^+$, $Na^+$, $K^+$), alkaline earth metal($Ba^{2+}$, $Ca^{2+}$, $Mg^{2+}$) and transition metal ions($Mn^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$, $Zn^{2+}$). The membrane electrode based on TBEDA appeared the best results as hydrogen ion electrode.

  • PDF

Extraction Spectrophotometric Determination of Antihistamines with Picric Acid (피크린 산에 의한 항히스타민제의 추출분광광도 정량)

  • 신태용;엄동옥
    • YAKHAK HOEJI
    • /
    • v.37 no.2
    • /
    • pp.119-123
    • /
    • 1993
  • A spectrophotomertic method is proposed for the determination of antihistamines. The method is based on solvent extraction of the ion pair formed between antihistamines and colored picric acid into chloroform. The binding state of antihistamines-picric acid complexes were presumed by IR and $^{1}$H-NMR spectra as intermolecular hydrogen bonding. This method was applicable to the determination of antihistamines in the pharamaceutical preparations.

  • PDF