• 제목/요약/키워드: Hydrogen explosion

검색결과 153건 처리시간 0.025초

Specific Process Conditions for Non-Hazardous Classification of Hydrogen Handling Facilities

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • 제12권3호
    • /
    • pp.416-420
    • /
    • 2021
  • Hazardous area classification design is required to reduce the explosion risk in process plants. Among the international design guidelines, only IEC 60079-10-1 proposes a new type of zone, namely zone 2 NE, to prevent explosion hazards. We studied how to meet the zone 2 NE grade for a facility handling hydrogen gas, which is considered as most dangerous among explosive gases. Zone 2 NE can be achieved considering the grade of release, as well as the availability and effectiveness of ventilation, which are factors indicative of the facility condition and its surroundings. In the present study, we demonstrate that zone 2 NE can be achieved when the degree of ventilation is high by accessing temperature, pressure, and size of leak hole. The release characteristic can be derived by substituting the process condition of the hydrogen gas facility. The equations are summarized considering relation of the operating temperature, operating pressure, and size of leak hole. Through this relationship, the non-hazardous condition can be realized from the perspective of inherent safety by the combination of each parameter before the initial design of the hydrogen gas facility.

CFD 시뮬레이션을 이용한 제한된 공간에서의 수소, LNG, LPG 폭발특성 비교 (Comparison of H2, LNG, and LPG explosion characteristics in a limited space using CFD Simulation)

  • 백주홍;이향직;장창봉
    • 한국가스학회지
    • /
    • 제20권3호
    • /
    • pp.12-21
    • /
    • 2016
  • 화석연료의 의존도를 줄이고자 대체에너지 연구가 활발하게 이루어지고 있는 현재, 산업에서 가장 많이 사용하고 있는 대체에너지 중 하나가 수소이다. 수소의 수요는 매년 꾸준히 증가하고 있으며, 수소의 생산 및 이송을 위한 설비도 늘어나고 있는 실정이다. 이에 따른 수소설비에서 중대사고가 발생할 확률 또한 증가할 것으로 예상된다. 또한 산업현장에서 가장 사고를 많이 초래하는 물질은 LPG 61%, 수소 12%, LNG 10%로 세 가지 가연성가스의 사고 빈도는 높은 축에 속한다. 따라서 산업용으로 많이 사용되며 사고다발성 가연성 가스인 수소, LNG, LPG가 제한된 공간에서 폭발했을 때의 폭발위험성에 대하여 CFD 시뮬레이션을 이용하여 계산을 하였고, 그 결과들을 기반으로 비교분석하여, 제한된 공간에서의 각 가스별 폭발에 대한 위험성을 검토하였다.

수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구 (Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space)

  • 백두산;김효규;박진욱;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제23권1호
    • /
    • pp.25-36
    • /
    • 2021
  • 온실가스 배출량을 줄이기 위해 내연기관 자동차에 대한 제한을 두고, 친환경자동차 보급 확대 정책을 내놓고 있다. 수소 전기자동차의 수소는 가연 범위 및 폭발 범위가 넓고, 폭발화염 전파속도가 매우 빠른 가연성 가스이기 때문에, 제조, 수송, 저장 시 누출, 확산, 점화 및 폭발 등의 위험성을 가지고 있다. 수소전기자동차의 연료탱크에는 폭발 등 위험성을 감소시키기 위해 온도감응식 압력방출장치(Thermally activate Pressure Relief Device, TPRD)가 있어, 사고가 발생했을 경우 폭발, 화재 등이 발생하기 전에 탱크 내부의 수소를 밖으로 방출한다. 그러나 지하주차장이나 터널과 같은 반밀폐공간에서 사고가 발생할 경우 공간 내 기류의 유동이 개방된 공간보다 미미하기 때문에 TPRD로부터 방출된 수소가스의 농도가 폭발하한계 이상으로 누적될 수 있는 등 문제가 발생할 수 있다. 따라서 본 연구에서는 TPRD의 노즐의 직경에 따라 시간에 따른 수소의 누출 유량을 분석하고, 반밀폐공간에서 수소가 누출될 경우 수소 농도변화를 수치해석으로 검토하였다. 노즐의 직경은 1 mm, 2.5 mm, 5 mm로 검토를 하였으며, 노즐 직경에 따라 지하주차장 내의 수소농도는 노즐의 직경이 클수록 빠른 시간에 농도가 높아지며, 최대값 또한 노즐 직경이 클수록 큰 것으로 분석되었다. 기류가 정체된 지하주차장에서는 노즐 주변에서 폭발하한계 이상의 수소 농도가 분포하는 것으로 분석되었으며, 폭발상한계를 넘지는 않는 것으로 분석되었다.

가연성 가스의 폭발특성에 대한 연구 (A Study on The Explosion Characteristics of Flammable Gases)

  • 오규형;김한석;이춘하
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.66-72
    • /
    • 1992
  • An experimental study was carried out to analyse the explosion characteristics of flammable gas-air mixtures. Used flammable gases were hydrogen, methane, acethylene, ethylene and pro-pane, explosion Pressure, explosoin pressure rising rate, and flame propagation velocity were measured experimentaly. The maximum explosion pressure and rising rate of flammmalbe gas air mixtures were appeared at the range of slightly higher concentration than the stoichiometric concentration. Initial pressure before explosion was controlled from 0.6 to 2.0kg/cm absolutly. Explosion pressure was increased with increment of the initial pressure, and the relationship between initial pressure and explosion pressure was Pe = KPi. The effect of vessel size on explosion characteristics was also analysed In this experiment. Explosion pressure was increased with in-creasing the vessel size, otherwise explosion pressure rising rate was decreased. When we locate a dummy material in vessel explosion pressure was decreased with increasing the dummy volume but exlosion pressure rising rate was increased.

  • PDF

수소가스사고의 피해범위 (Hazard Distance from Hydrogen Accidents)

  • 조영도
    • 한국가스학회지
    • /
    • 제16권1호
    • /
    • pp.15-21
    • /
    • 2012
  • 수소가스의 제트 누출에 의한 확산, 화재, 그리고 폭발에 의한 위험 범위를 분석하고, 안전거리 기준을 설정하기 위한 위험거리를 확산, 화재, 그리고 폭발에 대한 단순한 예측 식들을 제시하였다. 핀홀에 의한 누출과 같은 소량 수소가스 누출속도에 있어서 피해거리는 제트누출 확산에 의한 피해거리가 제트화재에 의한 피해거리보다 크며, 압력의 제곱근에 그리고 누출 홀의 직경에 비례하고 이는 수 십 미터에 이른다. 배관의 완전 파손 또는 저장 탱크의 큰 홀 발생과 같은 대량의 수소가스 누출속도에서는 제트화재의 피해거리가 개방공간의 가스운 폭발에 의한 피해거리보다 크며, 수 백 미터에 이른다. 수소충전소와 건물과의 최소이격거리 즉 안전거리 설정 기준을 대량 수소가스누출 사고시나리오를 기반으로 한다면, 도심지에 수소충전소는 안전거리 기준을 만족시키기 어려울 것이다. 따라서 대량의 수소가스 누출사고를 안전장치들을 통하여 예방하고, 안전거리 기준을 소량의 수소가스누출사고 기준으로 설정 할 수 있다. 그러나 대량누출 가능성이 있는 경우 학교와 병원 등 인구밀집 건물은 수 백 미터의 안전거리를 유지하여야 한다.

발전소 및 수전해 시스템의 수소 폭발 사고 사례 기반 위험성 평가 및 개선 방안 연구 (A Study on the Risk Assessment and Improvement Methods Based on Hydrogen Explosion Accidents of a Power Plant and Water Electrolysis System)

  • 전민재;장대진;이민철
    • 한국수소및신에너지학회논문집
    • /
    • 제35권1호
    • /
    • pp.66-74
    • /
    • 2024
  • This study addresses the escalating issue of worldwide hydrogen gas accidents, which has seen a significant increase in occurrences. To comprehensively evaluate the risks associated with hydrogen, a two approach was employed in this study. Firstly, a qualitative risk assessment was conducted using the bow-tie method. Secondly, a quantitative consequence analysis was carried out utilizing the areal locations of hazardous atmospheres (ALOHA) model. The study applied this method to two incidents, the hydrogen explosion accident occurred at the Muskingum River power plant in Ohio, USA, 2007 and the hydrogen storage tank explosion accident occurred at the K Technopark water electrolysis system in Korea, 2019. The results of the risk assessments revealed critical issues such as deterioration of gas pipe, human errors in incident response and the omission of important gas cleaning facility. By analyzing the cause of accidents and assessing risks quantitatively, the effective accident response plans are proposed and the effectiveness is evaluated by comparing the effective distance obtained by ALOHA simulation. Notably, the implementation of these measures led to a significant 54.5% reduction in the risk degree of potential explosions compared to the existing risk levels.

휴대형 라이다 스캐너와 AUTODYN를 이용한 수소 충전소 구조물의 3차원 폭발해석 (3D Explosion Analyses of Hydrogen Refueling Station Structure Using Portable LiDAR Scanner and AUTODYN)

  • 카칸 발루치;신찬휘;조용돈;조상호
    • 화약ㆍ발파
    • /
    • 제40권3호
    • /
    • pp.19-32
    • /
    • 2022
  • 수소는 다른 연료에 비해 에너지효율이 높고 유해물질이 배출되지 않아 미래의 청정에너지원으로 인식되고 있다. 그러나 수소는 밀도가 낮아 운반 및 저장시에 부피가 커서 압축하거나 특별한 운반체를 사용해야 하며, 공기중에 노출 시 화재나 폭발의 위험성이 있다. 수소-공기 혼합물의 폭발에 관한 실험이나 수치해석적 연구가 진행되어 오고 실물 수소 충전소를 대상으로 한 폭발 시뮬레이션에 관한 연구사례는 극히 드물다. 본 연구에서는 실제 수소 충전소를 대상으로 Lidar 스캐닝을 수행하여 point cloud 데이터를 획득하고 수소 충전소 3 차원 구조 모델을 작성한다. 3 차원 구조모델은 Ansys 사 AUTODYN 에 적용되어 수소 충전소의 수소폭발을 가정한 TNT 등가량의 폭발 시뮬레이션을 실시하고 주변에 전파하는 폭발압력을 계산하여, 수소 충전소 폭발에의한 주변 보안 건물의 안전거리에 관한 정보를 제공한다.

주택 내 수소연료전지 전용실의 폭발 위험성에 대한 실험적 연구 (An Experimental Study on the Explosion Hazards in the Fuel Cell Room of Residential House)

  • 박병직;김양균;황인주
    • 한국안전학회지
    • /
    • 제36권4호
    • /
    • pp.71-79
    • /
    • 2021
  • In this study, a real-scale fuel-cell room of volume 1.36 m3 is constructed to confirm the explosion characteristics of hydrogen-air mixture gas in a hydrogen-powered house. A volume concentration of 40% is applied in the fuel-cell room as the worst-case scenario to examine the most severe accident possible, and two types of doors (made of plastic sheet and wood) are fabricated to observe their effects on the overpressure and impulse. The peak overpressure and impulse based on distance from the ignition source are experimentally observed and assessed. The maximum and minimum overpressures with a plastic-sheet door are about 20 and 6.7 kPa and those with a wooden door are about 46 and 13 kPa at distances of 1 and 5 m from the ignition source, respectively. The ranges of impulses for distances of 1-5 m from the ignition source are about 82-28 Pa·s with a plastic-sheet door and 101-28 Pa·s with a wooden door. The amount of damage to people, buildings, and property due to the peak overpressure and impulse is presented to determine the safe distance; accordingly, the safe distance to prevent harm to humans is about 5 m based on the 'injuries' class, but the structural damage was not serious.

카본제조 부생가스 배출 안전성에 관한 연구 (A Study on the Safety of Carbon Manufacturing By-product Gas Emissions)

  • 주종율;정필훈;김상길;이성은
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.

수소충전소 폭발위험장소 완화를 위한 확산차단벽 최적화 설계 (Optimization of Designing Barrier to Mitigate Hazardous Area in Hydrogen Refueling Stations)

  • 안승효;오세현;김은희;이준서;마병철
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.734-740
    • /
    • 2023
  • Hydrogen emphasis on safety management due to its high potential for accidents from wide explosive limits and low ignition energy. To prevent accidents, appropriate explosion-proof electrical equipment with installed to safe management of ignition sources. However, designing all facilities with explosion-proof structures can significantly increase costs and impose limitations. In this study, we optimize the barrier to effectively control the initial momentum in case of hydrogen release and form the control room as a non-hazardous area. We employed response surface method (RSM), the barrier distance, width and height of the barrier were set as variables. The Box-Behnken design method the selection of 15 cases, and FLACS assessed the presence of hazardous area. Analysis of variance (ANOVA) analysis resulting in an optimized barrier area. Through this methodology, the workplace can optimize the barrier according to the actual workplace conditions and classify reasonable hazardous area, which is believed to secure safety in hydrogen facilities and minimize economic burden.