• Title/Summary/Keyword: Hydrogen Gas Filling

Search Result 39, Processing Time 0.033 seconds

Numerical Analysis of Fillling Flow in Type III Hydrogen Tank with Different Turbulence Models (Type III 수소 저장 용기에서 난류 모델(Turbulence Model)에 따른 충전(Filling)현상의 수치 해석적 연구)

  • KIM, MOO-SUN;RYU, JOON-HYOUNG;LEE, SUNG-KWON;CHOI, SUNG-WOONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.483-488
    • /
    • 2021
  • With continuous emission of environmental pollutants and an increase in greenhouse gases such as carbon dioxide, demand to seek other types of energy sources, alternative energy, was needed. Hydrogen, an eco-friendly energy, is attracting attention as the ultimate alternative energy medium. Hydrogen storage technology has been studied diversely to utilize hydrogen energy. In this study, the gas behavior of hydrogen in the storage tank was numerically examined under charge conditions for the Tpe III hydrogen tank. Numerical results were compared with the experimental results to verify the numerical implementation. In the results of pressure and temperature values under charge condition, the Realizable k-ε model and Reynold stress model were quantitatively matched with the smallest error between numerical and experimental results.

Strength Safety Study on the Stress Characteristics of a Composite Pressure Cylinder for 35MPa Hydrogen Gas Vehicle (35MPa 수소가스 자동차용 복합소재 압력용기의 응력특성에 관한 강도안전성 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.25-30
    • /
    • 2012
  • This paper presents a stress safety of a composite pressure cylinder in which is composed of an aluminum liner and composite layers with carbon fiber/epoxy and glass fiber/epoxy resigns. The composite pressure cylinder for a hydrogen gas vehicle contains 9.2 liter hydrogen gas, and hydrogen gases are compressed by a filling pressure of 35MPa. The FEM computed results are analyzed based on the US DOT-CFFC basic requirement for a hydrogen gas cylinder and KS B ISO specification. The FEM results indicate that the stress, 247MPa of an aluminum liner is sufficiently low compared with that of 272MPa, which is 95% level of a yield stress for aluminum. And, the carbon fiber composite layers in which are wound on the surface of an aluminum cylinder are safe because the maximum carbon fiber stresses from 29.43% to 28.87% in hoop and helical directions are below 30% for a given minimum required burst pressure level, respectively. The carbon fiber composite layers are also safe because the stress ratios from 3.40 to 3.46 in hoop and helical directions are above 2.4 for a minimum safety level, respectively.

On the Optimized Design of a Composite Hydrogen Fuel Tank using Taguchi Method (다구찌법을 이용한 복합소재 수소연료탱크의 최적설계에 관한 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.57-62
    • /
    • 2011
  • In this study, the optimized design for 130 liter storage fuel tank with 70MPa filling pressure has been investigated using a FEM technique and Taguchi design method. The strength safety of a composite fuel tank in which is fabricated by an aluminum liner of 6061-T6 material and carbon fiber wound composite layers of T800-24K has been analyzed based on the criterion of design safety of US DOT-CFFC and Korean Standard. The FEM computed results on the stress safety of 70MPa hydrogen gas tank were compared with a criterion of a stress ratio, 2.4 of US DOT-CFFC and Korean Standard, and indicated the safety. Thus, the optimized design elements based on the Taguchi's method were recommended as an aluminum liner thickness of 6.4mm, a carbon fiber laminate thickness in hoop direction of 31mm and a carbon fiber laminate thickness in helical direction of 10.2mm, which is represented by a design model of No. 5.

Hydrothermal Pre-treatment and Gasification of Solid Wastes to Produce Electrical Power and Hydrogen

  • Yoshikawa, Kunio
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2006.09a
    • /
    • pp.3-12
    • /
    • 2006
  • The main feature of these total technologies is that we can constitute the optimum treatment scheme fitting to the property of wastes, amount of wastes and energy requirement. For high moisture content wastes or biomass resources, high pressure steam process (MMCS) for crush, dry and deodorize wastes to produce high quality fertilizer of fuel is most appropriate. For dry or semi-dry solid wastes, the STAR-MEET system can be applied to produce low-BTU gases for power generation using duel fueled diesel engines of Stirling engines, and the REPRES and HyPR-MEET systems can be applied to produce hydrogen rich medium-BTU gas. For waste plastics and oils, liquefaction technology is best fit to produce light oil or kerosene equivalent fuel oils. These total technologies are completely different from the existent waste treatment technologies based on land-filling or incineration, and are expected to disseminate all over the world in the near future.

  • PDF

Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation (리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리)

  • Joo, Dong-Yeon;Seoe, Jae Min;Kim, Myung-Chul;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

Plasma Initiation in the KAERIT Tokamak (KAERIT 토카막의 플라즈마 생성 실험)

  • In, Sang-Ryul;Bak, Hae-Ill
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.246-252
    • /
    • 1988
  • Experiments on the hydrogen gas breakdown for plasma initiation in the KAERIT tokamak are described. The influence of the applied loop voltage, toroidal magnetic field, gas filling pressure, error magnetic field, and preionization is studied. It is concluded that the magnitude of the error field is the most important factor for successful discharge initiation. The gas breakdown voltage becomes minumum when the external compensating field most effectively corrects the net error field. Even though preionization effect is not prominent, it is exhibited more easily in the case of worse confinement. Discharge initiation conditions experimentally determined are compared with those calcuated from a theoretical model. Some other unknown physical processes maintain the operation range somewhat narrower than predicted by the present theoretical model. However, this model is adequate for the breakdown phase of tokamaks.

  • PDF

Discharge Characteristics of Large-Area High-Power RF Ion Source for Neutral Beam Injector on Fusion Devices

  • Chang, Doo-Hee;Park, Min;Jeong, Seung Ho;Kim, Tae-Seong;Lee, Kwang Won;In, Sang Ryul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.241.1-241.1
    • /
    • 2014
  • The large-area high-power radio-frequency (RF) driven ion sources based on the negative hydrogen (deuterium) ion beam extraction are the major components of neutral beam injection (NBI) systems in future large-scale fusion devices such as an ITER and DEMO. Positive hydrogen (deuterium) RF ion sources were the major components of the second NBI system on ASDEX-U tokamak. A test large-area high-power RF ion source (LAHP-RaFIS) has been developed for steady-state operation at the Korea Atomic Energy Research Institute (KAERI) to extract the positive ions, which can be used for the NBI heating and current drive systems in the present fusion devices, and to extract the negative ions for negative ion-based plasma heating and for future fusion devices such as a Fusion Neutron Source and Korea-DEMO. The test RF ion source consists of a driver region, including a helical antenna and a discharge chamber, and an expansion region. RF power can be transferred at up to 10 kW with a fixed frequency of 2 MHz through an optimized RF matching system. An actively water-cooled Faraday shield is located inside the driver region of the ion source for the stable and steady-state operations of RF discharge. The characteristics and uniformities of the plasma parameter in the RF ion source were measured at the lowest area of the expansion bucket using two RF-compensated electrostatic probes along the direction of the short- and long-dimensions of the expansion region. The plasma parameters in the expansion region were characterized by the variation of loaded RF power (voltage) and filling gas pressure.

  • PDF

Developmemt of Rice Husk Pellets as Bio-filter Media of Bio Scrubber Odor Removal System (왕겨펠렛 생물담체 개발 및 이를 이용한 bio scrubber형 악취제거 시스템 성능평가)

  • Bae, Jiyeol;Han, Sangjong;Park, Ki Ho;Kim, Kwang-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.554-566
    • /
    • 2018
  • The rice husk contains nutrients which can be easily utilized by microorganisms, and also has a water retaining ability, which played a crucial part in enabling it to become a biofilter media. In this study, we evaluated the applicability of rice husk pellet bio-scrubber as a microbiological carrier. The pelletization experiment of rice husk as a biological media was performed using PVA and EVA binder. Also, the feasibility tests of rice husk as a biological media for odor removal were carried out in order to know whether rice-husk contains useful components as a media for microbiological growth or not. Lastly, a combined test for odor gas absorption and biological oxidation was conducted using a lab scale bio-filter set-up packed with rice-husk pellets as wet-scrubber. The major components of the rice husk were carbon, hydrogen, nitrogen, and oxygen, while carbon acted as the main ingredient which comprised up to 23.00%. The C : N : P ratio was calculated as 45 : 1 : 2. Oxygen uptake rate, yield and decay rate of the rice husk eluent was calculated to be $0.0049mgO_2/L/sec$, 0.24 mgSS/mgCOD and 0.004 respectively. The most stable form of rice husk pellets was produced when the weight of the rice husk, EVAc, PVAc, and distilled water was 10 : 2 : 0.2 : 10. The prepared rice husk pellets had an apparent density of 368 g/L and a porosity of 59.00% upon filling. Dry rice husks showed high adsorption capacity for ammonia gas but low adsorption capacity for hydrogen sulfide. The bio-filter odor removal column filled with rice husk pellets showed more than 99.50% removal efficiency for NH3 and H2S gas. Through the analysis of circulation water, the prime removal mechanism is assumed to be the dissolution by water, microbial nitrification, and sulfation. Finally, it was confirmed that the microorganisms could survive well on the rice husk pellets, which provided them a stable supply of nutrients for their activity in this long-term experiment. This adequate supply of nutrients from the rice husk enabled high removal efficiency by the microorganisms.

Odor Reduction of Pig Wastewater Using Magnesia (in-situ test) (마그네시아를 이용한 돈분 폐수의 악취 저감(현장 시험))

  • Bae, Su Ho;Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.66 no.3
    • /
    • pp.202-208
    • /
    • 2022
  • In this study, we tried to obtain the optimal conditions to reduce odors generated from pig wastewater using magnesia (MgO) through in-situ test after producing a reactor for removing odors. For this purpose, the filling amount of magnesia, the injection amount of pig wastewater, the aeration method, the aeration amount and the aeration time were considered. The field experiment was conducted at Cheongwoon Livestock Farm, which has a pig wastewater reservoir. As the amount of magnesia added to the weight of wastewater (500 kg) increases, the amount of ammonia (NH3) and hydrogen sulfide (H2S) generated tended to gradually decrease. As a result of the test, ammonia and hydrogen sulfide in the pig wastewater decreased up to 65% and 77%, respectively, for 2 days aeration after 0.8% of magnesia was added to the reaction tank. The initial pH of the pig wastewater in the reactor was 8.2, and the pH was found to be 9.2 when magnesia was added up to 0.8%. In the light of this trend, it can be known that magnesia gradually increases the pH in the pig wastewater and makes it weakly alkaline. As the pH increases, part of the ammonia gas present in the pig wastewater vaporizes into the air and the remaining part is removed by precipitation after chemical bonding with dissolved magnesium ions and phosphate ions. In order to remove the odor of pig wastewater and turn it into compost, most of the existing livestock farms go through a six-month aeration process using microorganisms. In contrast, the current study proved the effect of removing odors from pig wastewater within 2 days through chemical reactions that do not affect microbial activity.