• 제목/요약/키워드: Hydro-mechanical analysis

검색결과 173건 처리시간 0.024초

Mechanical behavior and simplified models for the post-tensioned prestressed concrete lining

  • Fan Yang;Kang Liu;Yan-qiao Wang;Ming Huang
    • Structural Engineering and Mechanics
    • /
    • 제86권1호
    • /
    • pp.17-27
    • /
    • 2023
  • To investigate the mechanical behavior of the post-tensioned prestressed concrete lining (PPCL), the desilting tunnel of the Xiaolangdi Hydro Project in China is adopted as a case, and a detailed three-dimensional continuum model verified by the observation results is established for the PPCL. The radial stresses, longitudinal stresses, axial forces and bending moments of the PPCL under the completed cable tension condition (CCTC) and design water pressure condition (DWPC) are analyzed, respectively. The numerical results reveal that the PPCL concrete is significantly compressed in the circumferential direction by the prestress, while the prestress has a negligible influence on the radial stresses of the PPCL concrete. It should be noted that the concrete near the anchor slots has a complex and adverse stress state with stress concentration, longitudinal tensioning and large bending moment. In addition, a simplified shell model and a further simplified beam model which can take the influences of the prestress loss and the anchor slot into consideration are proposed for the PPCL. The results of the simplified models are in a good agreement with these of the three-dimensional continuum model, and they can be used as efficient approaches for the structural design and analysis of the PPCL.

TOUGH2-MP/FLAC3D를 이용한 한국형 기준 처분시스템에서의 열-수리-역학적 복합거동 특성 평가 (Numerical Analysis of Coupled Thermo-Hydro-Mechanical (THM) Behavior at Korean Reference Disposal System (KRS) Using TOUGH2-MP/FLAC3D Simulator)

  • 이창수;조원진;이재원;김건영
    • 방사성폐기물학회지
    • /
    • 제17권2호
    • /
    • pp.183-202
    • /
    • 2019
  • 고준위방사성폐기물의 처분터널 및 처분공 간격을 결정하고 처분시스템의 성능을 평가하기 위해서는 열-수리-역학적인 복합 거동 변화에 대한 이해가 반드시 필요하고 이를 반영하여 해석해야만 한다. 하지만 한국형 기준 처분시스템에서의 처분터널 및 처분공 간격을 결정하기 위해 수행된 기존의 연구들은 이러한 복합거동 특성을 반영하지 않고 열 해석 결과만을 근거로 처분시스템을 설계하였다. 따라서 본 연구에서는 열-수리-역학적인 복합거동 특성을 반영하여 한국형 기준 처분시스템의 성능을 TOUGH2-MP/FLAC3D를 이용하여 평가하였다. 고준위방사성폐기물이 처분된 이후 방사성 붕괴열에 의해 처분시스템의 온도는 급격히 증가하다가 붕괴열의 감소로 온도는 서서히 감소하였으며, 해석 기간 1,000년 동안 벤토나이트 완충재의 최고 온도는 설계 기준인 $100^{\circ}C$ 이하로 유지되는 것으로 나타났다. 처분용기와 벤토나이트 완충재의 계면에서의 최고 온도는 약 3.21년이 지난 시점에 용기의 중간 지점에서 약 $96.2^{\circ}C$로 나타났으며, 암반에서의 최고 온도는 폐쇄 후 약 17년이 지난 시점에서 약 $68.2^{\circ}C$로 계산되었다. 처분용기 부근 벤토나이트 완충재는 처분 초기에 온도 변화에 따른 건조현상이 발생하여 포화도가 감소하지만, 시간이 지남에 따라 주변 암반으로부터의 지하수 유입에 의해 포화도가 증가하는 것으로 계산되었다. 이후, 벤토나이트 완충재 및 뒷채움재 모두 약 266년 이후 완전히 포화되는 것으로 계산되었다. 처분시스템에서의 온도 변화에 따른 열응력 그리고 벤토나이트 완충재 및 뒷채움재의 팽윤압으로 인한 응력 변화가 처분장 주변 암반에 미치는 영향을 평가하고자 수치해석에서 계산된 응력을 스폴링 강도(spalling strength)와 Mohr-coulomb 파괴 기준식과 비교하였다. 계산 결과 일축압축강도와 스폴링 강도에 도달하지 않는 것으로 나타나 처분시스템이 스폴링에 의한 파괴는 나타나지 않을 것으로 판단되며, Mohr-coulomb 파괴 기준 역시 충족하는 것으로 나타났다. 본 연구에서 사용된 수치해석 코드와 방법론은 다양한 조건에서의 한국형 기준 처분시스템에 대한 성능평가뿐만 아니라, 복층 처분시스템에 대한 설계와 성능평가에 활용될 수 있을 것으로 판단된다.

전산유체역학을 이용한 초저낙차 상황에서의 도립형 횡류수차의 해석 및 설계 최적화 (Computational Analysis of an Inverted-type Cross-flow Turbine for Ultra-low head Conditions)

  • 함상우;하호진;이정완
    • 한국기계가공학회지
    • /
    • 제18권4호
    • /
    • pp.76-86
    • /
    • 2019
  • The cross-flow turbine is a key hydraulic power system that is widely due to low costs, high efficiency, and low maintenance. In particular, the cross-flow turbine considered as the most suitable turbine for low head situations as it is known to operate down to 5 m of water head. However, the conventional cross-flow turbine is unsuitable for ultra-low head situations with less than a 3 m water head. In this study, we propose an inverted-type cross-flow turbine to overcome the limitations of conventional cross-flow turbines under ultra-low head situations. First, we described the limitations of conventional turbines and suggested a new turbine for the ultra-low head circumstances. Second, we investigated the performance of the new turbine using CFD analysis. Results demonstrated the effects of the design parameters, such as number of blades and rotor diameter ratio, on the performance of the suggested turbine. As a result, we developed an inverted-type cross-flow turbine with up to 60% efficiency under low water head conditions.

Performance analysis of the passive safety features of iPOWER under Fukushima-like accident conditions

  • Kang, Sang Hee;Lee, Sang Won;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.676-682
    • /
    • 2019
  • After the Fukushima Daiichi accident, there has been an increasing preference for passive safety features in the nuclear power industry. Some passive safety systems require limited active components to trigger subsequent passive operation. Under very serious accident conditions, passive safety features could be rendered inoperable or damaged. This study evaluates (i) the performance and effectiveness of the passive safety features of iPOWER (innovative Power Reactor), and (ii) whether a severe accident condition could be reached if the passive safety systems are damaged, namely the case of heat exchanger tube rupture. Analysis results show that the reactor coolant system remains in the hot shutdown condition without operator actions or electricity for over 72 h when the passive auxiliary feedwater systems (PAFSs) are operable without damage. However, heat exchanger tube rupture in the PAFS leads to core damage after about 18 h. Such results demonstrate that, to enhance the safety of iPOWER, maintaining the integrity of the PAFS is critical, and therefore additional protections for PAFS are necessary. To improve the reliability of iPOWER, additional battery sets are necessary for the passive safety systems using limited active components for accident mitigation under such extreme circumstances.

암반동굴식 지하 LNG 저장 시스템 설계를 위한 기화율의 산정 (Determination of Boil-Off gas Ratio for the Design of Underground LNG Storage System in Rock Cavern)

  • 정소걸;이희석;정우철;박의섭
    • 터널과지하공간
    • /
    • 제17권1호
    • /
    • pp.56-65
    • /
    • 2007
  • 기존의 단열 시스템, 지하동굴 건설기술과 새로운 동결링 방벽기술을 결합하여 암반동굴식 지하 LNG 저장시스템이 개발되었다. 이 저장시스템의 기술적 적합성은 파일럿 동굴 실증시설의 건설과 운영을 통해 검증된 바 있으며, 조만간 실규모 프로젝트가 시작될 예정이다. LNG 저장시스템에서 중요한 사항 중의 하나는 극저온 열전달을 통해 장기간의 운영 기간동안 열손실을 최소화하는 것이다. 이 논문은 지하 LNG 저장 시스템의 설계를 위한 몇 가지 중요한 열전달 해석 결과를 제시하며, 기화율, 단열재 두께와 같은 설계 변수를 결정하기 위해 일련의 실규모 동굴에 대한 열전달 및 열-수리 해석을 실시하였다. 열-수리 연계해석결과 LNG 저장시설의 기화율은 초기 단계에서 0.04 %/day로 떨어져 유지되는 것으로 나타났다. 이 값은 암반내 존재하는 불연속면을 고려할 때 더욱 낮아질 수 있을 것으로 판단된다.

스위스 Mont Terri 지하연구시설 단층 내 유체 주입시험 모델링: 국제공동연구 DECOVALEX-2019 Task B(Step 2) (Numerical modelling of Fault Reactivation Experiment at Mont Terri Underground Research Laboratory in Switzerland: DECOVALEX-2019 TASK B (Step 2))

  • 박정욱;;;;박의섭
    • 터널과지하공간
    • /
    • 제29권3호
    • /
    • pp.197-213
    • /
    • 2019
  • 본 연구에서는 TOUGH-FLAC 연동해석기법을 이용하여 Mont Terri 지하연구시설에서 수행된 단층 내 물 주입시험을 수치적으로 모델링하고, 단층의 재활성과 수리역학적 거동 특성을 살펴보았다. TOUGH2 해석에서는 단층을 Darcy의 법칙과 삼승법칙(Cubic law)을 따르는 연속체 요소로 모델링하였으며, FLAC3D 해석에서는 미끄러짐과 개폐가 허용되는 불연속 인터페이스 요소를 통해 모사하였다. 현장에서 획득한 단층의 균열개방압력(fracture opening pressure), 주입율, 모니터링 압력, 변위 곡선 등을 바탕으로, 단층의 탄성적 변형과 파괴에 의한 수직팽창 특성을 반영할 수 있는 수리간극모델과 수리역학 커플링 관계를 해석모델에 반영하였다. 한편, 현지응력 조건, 단층의 강도 및 변형 특성에 따른 파라미터 해석을 실시하여 각 입력변수가 해석 결과에 미치는 영향을 분석하였으며, 이를 통해 현장시험 결과를 가장 잘 재현할 수 있는 파라미터 조합을 선정하였다. 해석 결과, 균열개방압력에서 단층의 주입율과 모니터링 압력이 크게 증가하는 현상을 합리적으로 재현할 수 있었다. 하지만, 동일한 입력 변수 조건에서 단층의 전단변위와 파괴영역의 범위는 현장시험 결과에 비해 과대평가되는 결과를 보였다. 이는 해석모델에서는 고압의 주입조건에서 단층의 지속적인 전단파괴가 유도되는 반면, 현장에서는 수리간극의 변화가 전단 미끄러짐보다는 인장력에 의한 단층면의 개방(tensile opening)에 크게 의존하는 것으로 추정되기 때문이다.

한국원자력연구원 내 지하처분연구시설 주변의 암반 손상대 영향 평가 (The Inflence of Excavation Damaged Zone around an Underground Research Tunnel in KAERI)

  • 권상기;김진섭;조원진
    • 화약ㆍ발파
    • /
    • 제26권2호
    • /
    • pp.11-19
    • /
    • 2008
  • 지하구조물의 굴착을 위한 발파 충격과 굴착후 응력의 재분포에 의해 발생하는 암반 손상대(Excavation Damaged Zone, EDZ)의 발생은 구조물의 장기적 안정성 경제성 안전성에 영향을 미친다. 본 연구에서는 조절발파기법으로 굴착된 한국원자력연구원 내 지하처분연구시설에서 굴착 후 발생하는 손상대 규모 및 특성을 측정, 분석하였으며 이를 모델링에 적용하여 손상대가 터널의 역학적, 수리적 거동에 미치는 영향을 평가하고자 하였다. KURT에서의 손상대 현장시험을 통해 1.5m의 손상구간을 확인할 수 있었으며 Goodman jack 시험과 실험실 암석실험을 통해 암반의 물성은 발파전 물성에 비해 대체적으로 50% 정도 변화함을 알 수 있었다. 이러한 암반 손상대 크기와 물성변화를 모델링에 적용하여 수리-역학적 연동해석을 실시하였다. 손상받지 않은 구간에 비해 손상대의 변형계수는 50%감소하며 수리전도도는 1 order증가하는 것으로 가정하였다. 해석 결과 손싱대를 고려하는 경우 변위는 증가하고 응력은 감소하며 지하수 유입량은 약 20% 정도 증가하는 것으로 나타났다.

Modeling the Effect of Water, Excavation Sequence and Reinforcement on the Response of Tunnels

  • Kim, Yong-Il
    • 한국지반공학회논문집
    • /
    • 제15권3호
    • /
    • pp.161-176
    • /
    • 1999
  • 본 논문에서는 기존의 불연속 변형 해석(DDA) 방법에 대한 세가지 방향의 새로운 개선 방법들이 제시되었다. 이 개선 방법들은 암반 균열에서 암석 블록과 지하수 흐름의 수리-역학적 커플링, 연속적인 하중 재하 또는 제하, 그리고 록볼트, 숏크리트와 콘크리트 라이닝에 의한 보강으로 구성되었다. Shi (1988)와 Lin (1995)에 의한 기존 DDA 프로.그램은 이 방법들에 의하여 추가로 개선되었으며, 이 새로운 DDA프로그램에 대한 몇 가지 적용예들이 제시되었다. 또한, 경부고속철도 공사의 일부인 운주 터널의 지하굴착에 대한 시뮬레이션을 통하여 절리를 통한 지하수의 흐름, 굴착순서, 그리고 록볼트와 숏크리트에 의한 보강이 터널안정에 미치는 영향을 연구하였다. 그 결과 절리를 통한 지하수의 흐름과 부적절한 굴착순서는 터널의 안정성에 악영향을 미치나, 한편 록볼트와 숏크리트에 의한 보강은 터널을 안정화 시킨다는 사실을 밝혀냈었다. 그 결과 세가지 개선방법이 추가된 DDA프로그램은 지하구조물 설계에 있어서 유용한 해석방법으로 사용될 수 있다는 사실을 보여주었다.

  • PDF

TOUGH2-MP/FLAC3D의 Barcelona Basic Model 해석 모듈 개발 (Implementation of Barcelona Basic Model into TOUGH2-MP/FLAC3D)

  • 이창수;이재원;김민섭;김건영
    • 터널과지하공간
    • /
    • 제30권1호
    • /
    • pp.39-62
    • /
    • 2020
  • 본 연구에서는 불포화토의 열-수리적 변화로 야기되는 역학적 거동 특성을 분석하고 장기 거동을 예측하기 위해 Barcelona Basic Model(BBM) 해석 모듈을 TOUGH2-MP/FLAC3D에서 구동할 수 있도록 개발하였다. 기본적으로는 TOUGH-FLAC에 BBM 해석 모듈을 개발하기 위해 사용된 선행연구의 방법과 마찬가지로 FLAC에서 제공하고 있는 Modified Cam Clay Model(MCCM)을 기반으로 User Defined Model(UDM)과 FLAC3D에서 제공하는 FISH function을 이용하였다. 본 연구에서 개발한 BBM 해석 모듈에서는 평균유효응력뿐만 아니라 흡입력의 변화에 따른 소성변형률을 모두 고려하였으며, 평균유효응력 및 흡입력 증가에 따른 항복면의 변화를 모두 반영할 수 있도록 하였다. 개발된 BBM 해석 모듈을 FLAC3D 매뉴얼에 기술되어 있는 MCCM 예제, BBM을 처음 제안한 선행연구에 언급되어 있는 예제들, 그리고 스웨덴 SKB 보고서에 언급되어 있는 실험실 시험 결과를 이용하여 검증하였다. 뿐만 아니라, 효과적인 BBM의 파라미터 도출을 목적으로 개발된 Quick tools의 검증을 위해 수행된 일련의 모델링 시험들을 동일하게 수행하고 선행연구에서 보고된 Quick tools와 Code_Bright의 결과와 비교함으로써 개발된 BBM 해석 모듈을 검증하였다.

CO2 지중저장에 따른 장기분지 내 단층안정성 기초해석 (Numerical Analysis of Fault Stability in Janggi Basin for Geological CO2 Storage)

  • 박정욱;김한나;이항복;박찬희;신영재
    • 터널과지하공간
    • /
    • 제33권5호
    • /
    • pp.399-413
    • /
    • 2023
  • 본 연구에서는 TOUGH-FLAC 연동해석 기법을 사용하여 장기분지 유망 저장소 부지에서의 CO2 주입을 수치적으로 모델링하고, 주변 지층과 단층에 야기되는 수리-역학적 안정성을 검토하였다. 대상부지의 현장조사와 3D 지질모델을 기반으로 3년간 32,850톤의 CO2 주입을 가정하여 시뮬레이션을 수행하였다. 저류층의 투수계수에 따른 CO2 플럼의 유동 경로를 분석한 결과, 투수계수를 10-14 m2로 가정한 경우 방사형 유동을 보이며 2년 9개월 경과 시 단층에 도달하는 것으로 나타났다. 투수계수를 10-13 m2로 가정한 경우에는 저류층을 따라 서쪽 방향의 유동이 우세하게 나타났으며 단층 방향으로의 유동은 거의 발생하지 않았다. 주입공 주변의 압력 변화는 3년 동안 0.6 MPa 이하로, 지층 및 단층의 역학적 안정성에 미치는 영향은 미미한 것으로 분석되었다.