• 제목/요약/키워드: Hydro power

검색결과 999건 처리시간 0.041초

Application of Dose to Curie Conversion Method using MCNP-4C code for the evaluation of Radionuclide Inventory in a Radioactive Waste Container

  • Sang-hee, Kang;Hwang, Ki-ha;Lee, Sang-chul;Lee, Kun-jai;Kim, Tae-wook;Kim, Kyoung-deok;Herr, Young-hoi;Song, Myung-jae
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.174-174
    • /
    • 2004
  • It is necessary to perform the radionuclide inventory assessment for the disposal of low and intermediate radioactive waste containers. The $\gamma$ nuclide analyzer can be used for the assessment of containers. However, if the radioactivity in the containers is extremely low or high, radionuclide inventory of the containers can not be evaluated properly. Also, gamma scanning method is time consuming and has economical burden to the utilities.(omitted)

  • PDF

A Novel Solid State Controller for Parallel Operated Isolated Asynchronous Generators in Pico Hydro Systems

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.358-365
    • /
    • 2007
  • This paper deals with a novel solid state controller (NSSC) for parallel operated isolated asynchronous generators (IAG) feeding 3-phase 4-wire loads in constant power applications, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of asynchronous generators. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 4-leg voltage source converter (CC-VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The complete system is modeled in MATLAB along with simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of isolated generating system consisting of NSSC and parallel operated asynchronous generators driven by uncontrolled pico hydro turbines and feeding 3-phase 4-wire loads.

마이크로 컴퓨터를 이용한 소수력발전소 PID 조속기에 관한 연구 (A Study on the Microcomputer-based PID Governor for Small Hydro Power Plant)

  • 신동렬;이규현;이원용
    • 대한전기학회논문지
    • /
    • 제36권7호
    • /
    • pp.492-500
    • /
    • 1987
  • Microcomputer-based PID governor which can be provided either stability or rapid response for small hydro power plant at low cost is developed and adapted to the 5 KW model hydro power for the performance test. The effects of PID gains on stability boundaries of the hydraulic turbine generating system is investigated. For the optimum selection of the PID gains, general equations are derived on the base of the experiments. This control system has a good performance at the model of hydro power plant. For the prediction of the control system, a mathematical model was developed and the results of the simulation using this model was matched with the experimental results.

  • PDF

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

AN ANALYSIS OF PERFORMANCE CHARACTERISTICS FOR SMALL HYDRO POWER PLANTS

  • Park, Wan-Soon;Lee, Chul-Hyung;Jeong, Sang-Man
    • Water Engineering Research
    • /
    • 제2권1호
    • /
    • pp.11-19
    • /
    • 2001
  • A performance prediction model for Small Hydro Power(SHP) sites has been studied and developed. Twelve SHP sites were selected and the performance characteristics were analyzed by using the developed model. Also, primary design specifications such as design flowrate, plant capacity, operational rate were suggested and feasibility for small hydro power sites were estimated. It was found that the design flowrate is most important parameter to exploit SHP plant and the methodology developed in this study can be a useful tool to analyze the performance of SHP sites.

  • PDF

Hydro-forming 공정을 위한 동적-외연적 유한요소해석 (A Dynamic-explicit Finite Element Analysis for Hydro-forming Process)

  • 정동원;황재신
    • 동력기계공학회지
    • /
    • 제8권3호
    • /
    • pp.23-29
    • /
    • 2004
  • In this paper, a finite element formulation using dynamic-explicit time integration scheme is used for numerical analysis of Hydro-forming processes. The lumping scheme is employed for the diagonal mass matrix and dynamic explicit formulation. Hydro-forming process for auto-body panel forming is analyzed by using dynamic-explicit finite element method. Further, the simulated results of the Hydro-forming processes are shown and discussed. Its application is being increased especially in the automotive industrial area for the cost reduction, weight saving, and improvement of strength.

  • PDF

해양소수력발전소 튜블러 수차 성능평가를 위한 현장시험 (Field Test for Performance Evaluation of a Tubular Turbine in Marine Small Hydro Power Plant)

  • 황영호;이영호;최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1070-1077
    • /
    • 2011
  • 본 연구는 해양소수력발전소에서의 튜블러 수차의 성능평가를 위한 현장시험 및 그 결과에 대한 내용을 포함하고 있다. 현장시험용 수차의 발전기 최소출력은 측정된 유효낙차, 출력 그리고 효율을 이용하여 검토되었다. 정격 및 최대 출력시험은 수차 설치현장의 조수간만의 차에 의한 영으로 인하여 동일한 실험조건을 확보할 수 없었기 때문에 모델시험에 의한 성능 데이터를 이용하여 환산된 값을 사용하였다. 현장시험에 의한 수차의 성능은 최소출력, 정격출력, 최대출력 운전점에서 보증출력 및 보증효율을 만족시키는 결과를 나타냄을 확인하였다.

오신호 입력에 따른 펌프의 고장징후 조기감지 성능분석 (Performance Analysis on Early Detection of Fault Symptom of a Pump with Abnormal Signals)

  • 정재영;이병오;김형균;김대웅
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.66-72
    • /
    • 2016
  • As a method to improve the equipment reliability, early warning researches that can be detected fault symptom of an equipment at an early stage are being performed out among developed countries. In this paper, when abnormal signal is input to actual normal signal of a pump, early detection studies on pump's fault symptom were carried out with auto-associative kernel regression as an advanced pattern recognition algorithm. From analysis, correlations among power of motor driving pump, discharge flow of pump, power output of pump, and discharge pressure of pump are exited. When the abnormal signal is input to one of those normal signals, the other expected values are changed due to the influence of the abnormal signal. Therefore, the fault symptom of pump through the early-warning index is able to detect at an early stage.

원자력발전소 가동중정비 도입 효용성 고찰 (A study of the effectiveness of Online Maintenance for Nuclear Power Plant)

  • 현진우;염동운;이상대
    • 에너지공학
    • /
    • 제29권1호
    • /
    • pp.52-57
    • /
    • 2020
  • 가동중정비(OLM : On-Line Maintenance)란 발전소 건전성 유지를 위해 운전 중에 수행하는 예방정비 활동으로 특히 안전설비에 대해 운전 중에 수행하는 예방정비 활동을 말한다. 국내 원자력발전소에서는 2009년부터 가동중정비 도입을 위한 타당성검토를 수행하였고 2010년 규제기관에서도 규제지침에 대한 연구과제를 완료하여 가동중정비 도입을 검토하였으나 후쿠시마 사고 등 원자력발전소의 대외여건 변화 등으로 도입검토가 중단된 상태이다. 하지만 원전의 안전성과 운전성을 향상시키기 위하여 근본적인 대책 수립이 요구되고 있는데 이를 위하여 필요한 가동중정비가 왜 필요한지 어떠한 효과가 있는지 등에 대하여 고찰하여 보았다.