• Title/Summary/Keyword: Hydraulic-Diameter

Search Result 473, Processing Time 0.024 seconds

액체 소듐 순환 구동용 소형 환단면 선형유도전자펌프의 특성 분석 (Characteristic Analysis of a Small ALIP for the Developing of the Liquid Sodium)

  • 김희령;김종만;남호윤;황종선;서장수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 전문대학교육위원 P
    • /
    • pp.1-3
    • /
    • 1999
  • EM (ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). (In the present study, pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF

항공기용 연료이송펌프 기어부 설계에 관한 연구 (A Study on the Design of Fuel Transfer Pumps Gear Part for the Aircraft)

  • 이정훈;김준태
    • 항공우주시스템공학회지
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2020
  • 본 논문은 국내 최초로 독자기술로 개발된 항공기용 연료이송펌프의 기어부를 설계하는 일련의 절차 및 그 결과에 대한 것이다, 기어펌프 방식이 베인펌프 방식에 비하여 전반적 성능이 우월하고, 내부 누설이 소량으로, 연료이송펌프의 설계에 필요사항에 부합하여 이 방식이 선정되었다. 기어 하우징은 흐름을 결정하는 중요한 변수인데, 기어의 외경을 고려하여 적절한 여유공간을 갖도록 설계하였다. 아울러, 모터가 연료이송펌프를 구동하기 위해 필요한 공압 및 축동력 등도 계산하였다.

Effect of Spacer Grids on CHF at PWR Operating Conditions

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.283-297
    • /
    • 2001
  • The CHF in PWR rod bundles is usually predicted by the local flow correlation approach based on subchannel analysis while difficulty exists due to the existence of spacer grids especially with mixing vanes. In order to evaluate the effect of spacer grids on CHF, the experimental rod bundle data with various types of spacer grids were analyzed using the subchannel code, COBRA-IV-i. For the Plain grid data, a CHF correlation was described as a function of local flow conditions and heated length, and then the residuals of the CHF in mixing vaned grids predicted by the correlation were examined in various kinds of grids. In order to compensate for the residual, three parameters, distances between grids and from the last grids to the CHF site, and equivalent hydraulic diameter were introduced into a grid parameter function representing the remaining effect of spacer grids predicted most of the CHF data points in plaing grids within $\pm$20 percent error band. Good agreement with the CHF data was also shown when the grid parameter function for mixing vaned grids of a specific design was used to compensate for the residuals of the CHF data predicted by the correlation.

  • PDF

IMPROVEMENTS OF CONDENSATION HEAT TRANSFER MODELS IN MARS CODE FOR LAMINAR FLOW IN PRESENCE OF NON-CONDENSABLE GAS

  • Bang, Young-Suk;Chun, Ji-Ran;Chung, Bub-Dong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제41권8호
    • /
    • pp.1015-1024
    • /
    • 2009
  • The presence of a non-condensable gas can considerably reduce the level of condensation heat transfer. The non-condensable gas effect is a primary concern in some passive systems used in advanced design concepts, such as the Passive Residual Heat Removal System (PRHRS) of the System-integrated Modular Advanced ReacTor (SMART) and the Passive Containment Cooling System (PCCS) of the Simplified Boiling Water Reactor (SBWR). This study examined the capability of the Multi-dimensional Analysis of Reactor Safety (MARS) code to predict condensation heat transfer in a vertical tube containing a non-condensable gas. Five experiments were simulated to evaluate the MARS code. The results of the simulations showed that the MARS code overestimated the condensation heat transfer coefficient compared to the experimental data. In particular, in small-diameter cases, the MARS predictions showed significant differences from the measured data, and the condensation heat transfer coefficient behavior along the tube did not match the experimental data. A new method for calculating condensation heat transfer coefficient was incorporated in MARS that considers the interfacial shear stress as well as flow condition determination criterion. The predictions were improved by using the new condensation model.

우수관망의 첨두유출량 감소를 위한 최적설계모형의 개발 (Development of an Optimal Sewer Layout Model to Reduce Peak Outflows in Sewer Networks)

  • 이정호;박정훈;장동일;전환돈;김중훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.485-489
    • /
    • 2008
  • To achieve the optimal sewer layout design, most developed models are designed to determine pipe diameter, slope and overall layout in order to minimize the least cost for the design rainfall. However, these models are not capable of considering the superposition effect of runoff hydrographs entering each junction. The suggested Optimal Sewer Layout Model (OSLM) is designed to control flows and distribute the node inflows while taking into consideration the superposition effect for reducing the inundation risk from the sewer pipes. The suggested model used the genetic algorithm to determine the optimal layout, which was connected to the SWMM (Storm Water Management Model) for the calculation of the hydraulic analysis. The suggested model was applied to an urban watershed of 35 ha, which is located in Seoul, Korea. By using the suggested model, several rainfall events, including the design rainfall and excessive rainfalls, were used to generate runoff hydrographs from a modified sewer layout. By the results, the peak outflows at the outlet were decreased and the overflows were also reduced.

  • PDF

저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해 (Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning)

  • 조완근;권기동;최상준;송동익
    • 한국환경과학회지
    • /
    • 제13권9호
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

수직 흐름 제올라이트 갈대 여과상의 간헐적 주입에 의한 인공하수 처리 (Vertical Flow Zeolite-Filled Reed Bed for Treatment of Artificial Sewage with Intermittent Feeding)

  • 서정윤;김태형;최민수
    • KSBB Journal
    • /
    • 제18권2호
    • /
    • pp.140-144
    • /
    • 2003
  • 제올라이트로 충진된 수직 흐름 갈대 여과상에 인공하수를 주입하면서 처리효율을 조사하였다. 여과상 표면적 $m^2$당 1일 314 L의 인공하수가 6시간마다 10분 동안 간헐적으로 주입되었다 각 항목별 연중 평균 처리효율은 CO $D_{Cr}$ , 95.1%, T-N 49.5%, N $H_4$$^{+}$-N 99.4%, T-P 56.4%이었다. T-N의 처리효율은 가동 시간이 경과함에 따라 현저하게 감소하였다. 여과상의 상층에서 많은 인이 흡착되었으며 흡착된 인 중 대부분은 Fe-p, Ca-P와 환원가용성 Fe-P이었다.

Equilibrium and Dynamic Adsorption of Methylene Blue from Aqueous Solutions by Surface Modified Activated Carbons

  • Goyal, Meenakshi;Singh, Sukhmehar;Bansal, Roop C.
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.170-179
    • /
    • 2004
  • The equilibrium and dynamic adsorption of methylene blue from aqueous solutions by activated carbons have been studied. The equilibrium studies have been carried out on two samples of activated carbon fibres and two samples of granulated activated carbons. These activated carbons have different BET surface areas and are associated with varying amounts of carbon oxygen surface groups. The amounts of these surface groups was enhanced by oxidation with $HNO_3$ and $O_2$ gas at $350^{\circ}C$ and decreased by degassing at increasing temperatures of $400^{\circ}$, $650^{\circ}$ and $950^{\circ}C$. The adsorption increases on oxidation of the carbon surface and decreases on degassing. The increase in adsorption has been attributed to the formation of acidic carbon-oxygen surface groups and the decrease in adsorption on degassing to their elimination. The dynamic adsorption studies have been carried out on the two granulated activated carbons using two 50 mm diameter glass columns at a feed concentration of 300 mg/L and at different hydraulic loading rates (HLR) and bed heights. The minimum achievable concentrations are comparatively lower while the adsorption capacities are higher for GAC-S under the same operating conditions. The adsorption capacity of a carbon increases with increase in HLR but the rate of increase decreases at higher HLR values.

  • PDF

가스터빈용 열교환기의 주름진 덕트에서 종횡비 변화가 열전달 특성에 미치는 영향 (Effects of Duct Aspect Ratio on Heat Transfer in Wavy Duct of Heat Exchanger of Gas Turbine)

  • 김한호;황상동;조형희;최재호;전승배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.339-344
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics in wavy ducts of primary surface heat exchanger. Experiments using a naphthalene technique are carried out to determine the local transfer characteristics for flow in the corrugated wall duct. The aspect ratios of the rectangular duct cross-section are 7.3, 4.7 and 1.8 with a corrugation angle of $145^{\circ}$. The Reynolds numbers, based on the duct hydraulic diameter, are ranged from 1000 to 5000. The local heat/mass transfer measurement is conducted in the spanwise directions. The results show that Tayler-Gortler vortices exist on the pressure surface. Flow separation on the suction surface appears at a high Reynolds number resulting in a sharp decrease in the local transfer rates, but relatively high transfer rates are obtained in the reattachment region.

  • PDF

엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석 (NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN COOLING CHANNEL WITH A STAGGERED V-SHAPED RIB)

  • 명현국;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.125-130
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration ($h/D_h$) of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth channel with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 2.5 times higher streamwise pressure drop than the latter ones. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered ones give about 2 times higher values than the latter ones with more uniform heat transfer distribution.

  • PDF