  • An experimental research was performed employing the two stage anaerobic digestion of the mixture of the nightsoil and septic tank sludge to determine the effects of various hydraulic retention time of the digestion on chemical characteristics and treatment effeciency, thus determining the proper retention time. Results of the research are as follows, 1. Volatile-acid decreased as HRT increased. 2. Alklinity and ammonia-N tended to increase as HRT increased as did pH values, however, were observed to be constant at higher HRT values than 15 days. 3. The removal efficiencies of TBOD, TCOD and VS increased as HRT increased. 4. The removal efficiency of volatile solid decreased as VS loading increased. 5. It was observed that the rates of gas production were: 0.33 with HRT of 5 days, 0.58 with HRT of 15 days and $0.57m^3/kg$ VS fed/day with HRT of 25 days respectively. It is believed that the highest rate of gas production was at HRT of 15 days. 6. The sludge settling experiment showed that the minimum settling time required to ensure the desired underflow concentraton was estimated to be 8.6 days.

  • PDF

Effects of Rotational Speed and Hydraulic Residence Time on the Ammonia Removal of a Rotating Biological Contactor (RBC) (회전속도와 수리학적 체류시간이 회전원판식(Rotating Biological Contactor;RBC) 여과조의 암모니아 제거에 미치는 영향)

  • 오승용;조재윤;김종만
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.142-150
    • /
    • 2003
  • Performance of a biological filter, the rotating biological contactor (RBC), is affected by rotational speed and hydraulic residence time (HRT). A RBC with a disc diameter of 62 cm, total surface area of 48.28 $m^2$, volume of 0.34 ㎥, and submergence ratio of 35.4% was tested for the combinations of five rotational speeds (1, 2, 3, 4 & 5 rpm) and three HRT (0.5, 1.0 & 2.0 hr) to find out the maximum removal efficiencies of total ammonia nitrogen (TAN) and nitrite nitrogen of a simulated recirculating aquaculture system. Ammonia loading rate in the system was 25 g of TAN/ ㎥. day. Removal efficiencies were checked when TAN concentrations in the system stabilized for 3 days in each treatment. The concentration of TAN in the system decreased with increasing rotational speed of the RBC up to 4 rpm in all HRT (P<0.05). At the rotational speed of 5 rpm, the efficiencies decreased in all HRT (P<0.05). When the rotational speeds were 1, 2, 3, 4, and 5 rpm, TAN concentrations in the system were 1.35, 0.94, 0.69, 0.66, and 0.76 mg/L at the 0.5 hr HRT, 2.86, 1.18, 0.96, 0.87, and 1.11 mg/L at the 1.0 hr HRT, and 5.30, 2.44, 1.99, 1.77, and 2.01 mg/L at the 2.0 hr HRT, respectively. The TAN removal efficiencies of the RBC at the rotational speeds of 1, 2, 3, 4, and 5 rpm were 32.9, 49.5, 65.1, 72.9, and 62.9% in 0.5 hr HRT,33.1, 74.1, 87.1, 95.8, and 78.5% in 1.0 hr HRT, and 35.5, 76.7, 89.6, 97.0, and 85.5% in 2.0 hr HRT, respectively. TAN removal efficiency of RBC per pass increased with increasing HRT. However, TAN concentration in the system also increased. The best operating condition among the treatments was obtained at the treatment of 0.5 hr HRT and 4 rpm (P<0.05). The TAN concentration was 0.66 mg/L. Concentrations of nitrite nitrogen (NO$_2$$^{[-10]}$ -N) in the system decreased with increasing rotational speed in all HRT while that in the system increased with increasing HRT in all rotational speeds. The ranges of NO$_2$$^{[-10]}$ -N concentrations at HRT of 0.5, 1.0, and 2.0 hr in the system were 0.26~0.32, 0.31~0.56, and 0.43~l.45 mg/L, respectively. The ranges of daily removal rates of TAN in this system were 20.03~23.0 g TAN/㎥ㆍday and those of nitrite nitrogen were 19.65~30.25 g NO$_2$$^{[-10]}$ -N/㎥ㆍday.

Assessment of Optimum Hydraulic Retention Time (HRT) for Maximum Biogas Production and Total Volatile Solid (TVS) Removal Efficiency of Semi-Continuously Fed and Mixed Reactor (SCFMR) Fed with Dairy Cow Manure (젖소분뇨로부터 최대 바이오가스 생산과 유기물 제거효율을 달성하기 위한 반건식 간헐주입 연속혼합 혐기성반응조의 최적 수리학적 체류시간 도출을 위한 연구)

  • Kang, Ho;Kim, Sun-Woo;Jeong, Ji-Hyun;Ahn, Hee-Kwon;Jung, Kwang-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.696-704
    • /
    • 2015
  • This study was carried out to evaluate the optimum operational condition of Semi-continuously Fed and Mixed Reactor (SCFMR) to treat the dairy cow manure and saw dust mixture. Step-wise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) were utilized until the biogas volume became significantly decreased at mesophilic temperature ($35^{\circ}C$). The optimum operating condition of the SCFMR fed with TS 13% dairy cow manure and saw dust mixture was found to be an HRTs of 25 days and its corresponding OLRs of $4.45kg\;VS/m^3-day$. At this condition the biogas and methane production rates were 1.44 v/v-d and 1.12 v/v-d (volume of biogas per volume of reactor per day), respectively and the TVS removal efficiency of 37% was achieved. The successful operation with such a high OLR was due to the high reactor alkalinity concentration of 14,500~15,600 mg/L as $CaCO_3$ as a result of the characteristic of the original substrate, dairy cow manure and saw dust mixture whose alkalinity was more than 8,000 mg/L as $CaCO_3$. The parameters for the reactor stability, the ratios of volatile acids and alkalinity concentrations (V/A) and the ratio of propionic acid and acetic acid concentrations (P/A) appeared to be 0.11 and 0.43, respectively, that were greatly stable in operation. Free ammonia toxicity was not experienced due to the long term acclimation by the reactor TS content ranged 7.2~10.4% during the entire operational period.

Performance Evaluation of Backwash Hydrodynamic Separator Filter for Treatment of Micro Particles (역세척 Hydrodynamic Separator Filter를 이용한 미세입자 제거 특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.694-701
    • /
    • 2012
  • The main purpose of this study is to evaluate of backwash system of hydrodynamic separator filter (HSF) with solar powered submerged pumps. It consists of a photovoltaic solar array, control electronics, battery, and two submersible pump powered by a 12 voltage DC motor. The laboratory scale study on treatable potential of micro particles using backwash HSF that was a combined with perlite filter cartridge and backwash nozzles. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particle sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin partices, silica gel particles, and commercial area manhole sediment particles. HSF was made of acryl resin with 250 mm of diameter filter chamber and overall height of 800 mm. Four case test were performed with different backwashing conditions and determined the SS removal efficiency with various surface loading rates. The operated range of surface loading rate was about 308~$1,250m^3/m^2/day$. It was found that SS removal efficiency of HSF using two submersible pumps improved by about 18% compared with HSF without backwash. Nonpoint control devices with solar water pumping systems would be useful for backwashing the filter in areas with not suppling electricity and reduce filter media exchange cost.

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

Anaerobic Treatment of Leachate Solubilized from Thermal Hydrolysis of Sludge Cake (하수슬러지 케이크 열수분해 탈리액의 혐기성 분해 특성)

  • Kang, Ho;Oh, Baik-Yong;Shin, Kyung-Sook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.583-589
    • /
    • 2015
  • This study was performed to evaluate the feasibility of anaerobic pretreatment for the leachate solubilized from thermal hydrolysis of sewage sludge cake. Overall process for the treatment of sludge cake consists of thermal hydrolysis, crystallization of magnesium, ammonium, and phosphate (MAP) for the leachate and anaerobic digestion of supernatant from MAP crystallization. The experimental evidence showed that the optimum ratio of Mg : P for the struvite crystallization of leachate solubilized from thermal hydrolysis of sludge cake was 1.5 to 1.0 as weight basis at the pH of 9.5. With this operational condition, the removal efficiencies of ammonia nitrogen and phosphorous achieved 50% and 97%, respectively. The mesophilic batch test showed that the ultimate biodegradability of the supernatant from MAP crystallization reached 63% at S/I ratio of 0.5. The readily biodegradable fraction of 90% ($S_1$) of the MAP supernatant BVS (Biodegradable Volatile Solids, $S_0$) degraded with $k_1$ of $0.207day^{-1}$ for the initial 17 days where as the rest slowly biodegradable fraction ($S_2$) of 10% of BVS degraded with $k_2$ of $0.02day^{-1}$ for the rest of the operational period. Semi-Continuously Fed and Mixed Reactor (SCFMR) was chosen as one of the best candidates to treat the MAP supernatant because of its total solids content over 6%. Maximum average biogas production rates reached 0.45 v/v-d and TVS removal efficiency of 37~41% was achieved at an hydraulic retention time (HRT) of 20 days and its corresponding organic loading rate (OLR) of 1.43 g VS/L-d.