• Title/Summary/Keyword: Hydraulic load cell

Search Result 33, Processing Time 0.02 seconds

Characteristics of a Double-Tube Structure for the Hydraulic WIM Sensor

  • Moon, Young-Soon;Son, Won-Ho;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.19-23
    • /
    • 2014
  • A new hydraulic tube structure for WIM sensor of a new generation is presented in this paper. The double-tube structure has been developed in order to improve the performance of the hydraulic load cell. The double-tube structure hydraulic element could be reduced by 46% in pressure changes according to temperature compared to a single-tube structure. In addition to the nonlinearity can be reduced by 67.19% at the same load condition. The hydraulic load cell shows an excellent linearity and measurement accuracy as the result of the static load test.

A study on the improvement of loading and unloading work in laver aquaculture industry (양식 생김의 양륙 작업 개선에 관한 연구)

  • MIN, Eun-bi;YOON, Eun-a;HWANG, Doo-jin;KIM, Ok-sam;YOO, Geum-bum
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.1
    • /
    • pp.45-54
    • /
    • 2020
  • In this study, an automatic system for improving the working environment and increasing production efficiency of a laver aquaculture industry in Korea was developed by combining a hydraulic control system and a load cell in a current landing work of the laver. The improved gathering laver system allowed the automatic gathering process of the laver in the sea with the hydraulic control system connected to a cutting machine of the laver on the operating ship, which has been used for gathering the laver semi-automatically in a form of the traditional farming method. The transporting process of the laver from an operating ship to the land was improved as follows. A frame installed on the operating ship and the bag nets were designed and made to hold about 1,000 kg of the laver inside. The bag nets contain the laver on the improved operating ship were tied in knots and hooked on a crane using a load cell. The weight is measured immediately by lifting the bag nets through the load cell system. Weight information is communicated to the fishermen and successful bidders through the application. The advantages of the improved system can help fishermen to fish by improving their working environment and increasing production efficiency. The field survey to improve the landing operation of the laver aquaculture was conducted in Gangjin, Goheung, Shinan, Wando, Jindo, and Haenam in South Jeonnam Province. A total of 10 sites including Gunsan in Jeonbuk Province, Daebu Island in Ansan City, Jebu Island in Hwaseong City in Gyeonggi Province, and Seocheon in Chungnam Province were searched to collect data. Prototypes of the system were tested at the auction house of laver located in Goheung, where laver collection using hydraulic control and landing using road cell could be improved.

A Study on the Performance Certification of 5,200ton Compression Load Tester (5,200톤 재하 시험장비의 성능 검증에 관한 연구)

  • Kim, Kwang-Young;Choi, Young-Ho;Ham, Young-Bog;Choi, Byung-Oh;Lee, Dong-Ha
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.149-154
    • /
    • 2001
  • In case of high capacity load force as millions of tons, it is difficult to measure the force with load cell. But we can measure and calculate the force with applied pressure and ram area of hydraulic jack. The 5,200 ton compression load tester is composed of thirteen hydraulic jack with 400 ton capacity. This paper explains the method of measuring the vertical compression load and provides characteristics of unit jack, and displacement of upper structure under maximum load condition.

  • PDF

New uroflowmetry technique measuring hydraulic pressure for prostate diagnostics (전립선 진단을 위한 수압 측정 방식의 새로운 요 유량 계측기법)

  • Kim, Kyung-Ah;Choi, Sung-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.179-186
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostate hypertrophy (BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary flow rate. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiment, variance of the pressure signal was more than 50 % smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

Numerical Analyses of O-Cell Load Test on Pile (양방향말뚝재하시험의 수치해석)

  • Joo, Yong-Sun;Kim, Nak-Kyoung;Kim, Woong-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.748-753
    • /
    • 2008
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurisation causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. Bi-directional load tests using O-cell are now becoming common practice around the world, particularly where the loads to be applied are high or where it is not convenient to perform top-down loading tests. In the study, calculate ultimate capacity of bi-directional load test using FEM and beam on elasto-plastic foundation theory.

  • PDF

Creative Design of Large-Angle Pin Type Load Cell for the Overload Limiter of a Movable Crane (이동식크레인의 과부하방지장치용 광각도 핀형 로드셀의 창의적 설계)

  • Han, Dong Seop;Ha, Jeong Min;Han, Geun Jo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • An overload limiter is used to prevent its overturning accident during an operation of a movable crane. Recently the indirect measuring method, which measures hoisting load and overturning moment of overload limiter, demands instead of the existing method, which measures only hoisting load. The indirectly measuring method is how to conduct the hoisting load and overturning moment as measuring the load of hydraulic cylinder for a luffing driving of boom. So we need to develop the multi-angular pin type load cell with the measuring angle of ${\pm}10$ degree instead of the existing load cell with the measuring angle of ${\pm}2$ degree. In this study the finite element analysis is conducted to evaluate the effect of the aspect ratio of measuring cross section on the measuring limit of the load cell to develop the many-angular pin type load cell. For this investigation, the aspect ratio of measuring cross section and load applying angle were adopted as design parameters and the stresses of measuring part were evaluated for each parameter.

Design and Analysis of Column Type Sensing Element for Large Compact Load Cell (대용량 Compact형 로드셀의 기둥형 감지부 설계 및 해석)

  • Kang, Dae-Im;Shin, Hong-Ho;Kim, Jong-Ho;Park, Yon-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.601-607
    • /
    • 2003
  • The column type is used as the sensing element of the load cell to measure the large force in the range of 10$^4$~ 10$^{7}$ N. However. it is not easy to handle the load with large capacity due to its size. It is, therefore, necessary to design a compact load cell with a low aspect ratio. Thus this paper showed the characteristic evaluation of compact load cell with respect to the shape of supporting plate. The supporting plate of the load cell was an annular type with inner(D$_{i}$) and outer(D$_{o}$) diameters. Using the strain distribution obtained from FEM. the supporting plate was designed to get the stable output voltage of the load cell. The three designed supporting plates were manufactured, and the result of characteristic experiment of the load cell, using the 10 MN hydraulic force standard machine, was compared with FEM.M.M.

Validation of Urine Volume Evaluation by Hydraulic Pressure Measurement (압력 측정에 의한 요량 계측의 유용성 분석)

  • Kim, Kyung-Ah;Choi, Sung-Soo;Lee, In-Kwang;Park, Kyung-Soon;Kim, Wun-Jae;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.577-584
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostatic hypertrophy(BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary volume. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiments, variance of the pressure signal was more than 50% smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

Model Test of O-Cell Pile Load Test with Variable End Plate (가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험)

  • Joo, Yong-Sun;Kim, Nak-Kyung;Kim, Sung-Kyu;Kim, Ung-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

A Study on the Characteristic of Contact Pressure for CPB (Cold Pad Batch) Padder Roll Controlled by Hydraulic Single Cell (단일 유압 Cell로 제어되는 CPB(Cold Pad Batch)용 패더롤의 접촉압력 특성 연구)

  • Cho, Kyung-Chul;Lee, Eun-Ha;Jo, Soon-Ok;Park, Si-Woo;Hwang, Youn-Sung;Kim, Soo-Youn
    • Textile Coloration and Finishing
    • /
    • v.29 no.2
    • /
    • pp.86-96
    • /
    • 2017
  • To make uniform pressure distributed over the contact surface was necessary to cold pad batch dyeing machine. In this study, to confirm characteristic of flexibility and the contact pressure distribution through experimental analysis of padder roll were controlled by hydraulic cell. When there were no load pressure only inner pressure, the value of displacement in the center of padder were greater than the end of the padder. The results of this study showed that the padder had the optimum value of inner pressure for uniform contact pressure distribution. Measuring the contact pressure in a padder system were driven by using a pre-scale film. Uniform contact pressure distribution of cell padder were a linearly with load pressure and inner pressure. When the load pressure was less than 8 tons, the inner pressure for the uniform contact pressure was 1~4 bar. The padder roll performance curves proposed in this study were available for practical production environments and various roll designs.