• 제목/요약/키워드: Hydraulic efficient

검색결과 259건 처리시간 0.021초

수중 잠제구조물의 파랑 전달율과 안정성 및 기능성 평가 (Estimation on the Wave Transmission and Stability/Function Characteristics of the Submerged Rubble-Mound Breakwater)

  • 김용우;윤한삼;류청로;손병규
    • 한국수산과학회지
    • /
    • 제36권5호
    • /
    • pp.528-534
    • /
    • 2003
  • The 2-D hydraulic experimental results for the submerged rubble-mound structure, we have been concerned with the slability/function characteristics of the structures by the effects of wave force, scour/deposition at the toe and the wave transmission ratio at the lee-side sea. So, to investigate the variation characteristics of the wave transmission ratio which depended on a geometrical structure of the submerged breakwater profiles, the critical conditions for the depth of submergence and crest width were obviously presented. In summary, the results lead us to the conclusion that the wave control capabilities of submerged breakwaters by the variation of the submergence depth is higher than about 4 times the degree at the efficiency than the that of crest width. The destruction of the covering block at the crest generated at the region which was located between the maximum and minimum damage curve, and it's maximum damage/failure station from the toe of the structure was $0.2\;L_s.$ As the wave transmission coefficient and the slope of the structure increase, the damage/failure ratio and the maximum scour depth at the toe was extended, respectively. When the maximum scour depth happened, the destruction of the covering block which was located at the toe generated at the front of the submerged rubble-mound breakwater. Finally, it was found from the results that the optimization of the structure may be obtained by the efficient decision of the submergence depth and crest width in the permissible range of the wave transmission ratio.

황산염환원균 고정화 담체를 이용한 산성광산배수 처리 (Treatment of Acid Mine Drainage Using Immobilized Beads Carrying Sulfate Reducing Bacteria)

  • 김경만;허원;백환조
    • 자원환경지질
    • /
    • 제41권1호
    • /
    • pp.57-62
    • /
    • 2008
  • 휴폐광지역의 산성광산배수를 처리하기 위한 자연정화처리시설로서 소택지의 설치가 증가하고 있다. 이러한 소택지의 기질물질로서는 흔히 석회석, 참나무조각, 버섯퇴비 등이 벌크형태로 적용된다. 이러한 소택지의 정화효율은 시간이 지남에 따라 점차 저하되며, 특히 산성배수와의 화학반응에 의한 기질물질 층의 투수계수 감소에 주로 기인한 것으로 파악된다. 본 연구의 목적은 산성광산배수 처리시설에서 황산염환원균(SRB) 고정화 담체의 적용성을 평가하기 위한 것이다. 고정화담체는 유기물질인 버섯퇴비와 참나무 퇴비, pH 완충제인 석회석가루 등을 토양미생물을 접종한 m-CSB와 혼합하여 제작하였다. 본 실험에서 고정화담체는 벌크형태에 비하여 pH, 황산염제거율 및 중금속 제거율에서 효율이 우수함을 확인할 수 있었다.

분산형 용수공급시스템 구축을 위한 정수처리시설 최적 위치 결정 (Determination of the Optimal Location for Water Treatment Plants in the Decentralized Water Supply System)

  • 장동일;하금률;전환돈;김정현;강기훈
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2013
  • Major issues in water supply service have changed from expansion of service area to improvement of service quality, i.e., water quality and safety, and early response to emergency situation. This change in the service concept triggers the perceptions of limitation with the current centralized water supply system and of necessities of decentralized (distributed) water supply system (DWSS), which can make up the limitations. DWSS can reduce the possibility of water supply outage by establishing multiple barriers such as emergency water supply system, and secure better water quality by locating treatment facilities neighboring consumers. On the other hand, fluctuation of water demand will be increased due to the reduced supply area, which makes difficult to promptly respond the fluctuating demand. In order to supplement this, hybrid water supply system was proposed, which combined DWSS with conventional water supply system using distributing reservoir to secure the stability of water supply. The Optimal connection point of DWSS to existing water supply network in urban area was determined by simulating a supply network using EPANET. Optimal location of decentralized water treatment plant (or connection point) is a nodal point where changes in pressure at other nodal points can be minimized. At the same time, the optimal point should be selected to minimize hydraulic retention time in supply network (water age) to secure proper water quality. In order to locate the point where these two criteria are satisfied optimally, Distance measure method, one of multi-criteria decision making was employed to integrate the two results having different dimensions. This methodology can be used as an efficient decision-support criterion for the location of treatment plant in decentralized water supply system.

유입원수 조류제거를 위한 high rate DAF 최적화 연구 (High Rate Dissolved Air Flotation (DAF) for the Removal of Algae Species)

  • 정우식;안주석;송근원;오현제
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.415-419
    • /
    • 2017
  • In recent years there have been large increases in the hydraulic loading rates used to design dissolved air flotation (DAF) facilities for drinking water applications. High rate DAF processes are now available at loading rates of 20 to $40m^3/m^2{\cdot}h$. This research evaluated dissolved air flotation as a separation method for algae and organic compounds from water treatment plants. During the service period of 2016. 5. to 2017. 6., DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU). As a result of analyzing the algae cell counts in the influent source, it was expressed at 100-120 cells/mL. In DAF treated water, the removal efficient of alge cell counts was found to be upto 90%. The stable turbidity and algae removal were confirmed by operating the high rate DAF process under the condition of the surface loading rate of $30m^3/m^2{\cdot}hr$.

저류지에 의한 우수의 수질개선 효과 연구 (A Study on the Effect of Water Quality Improvement of a Storm Sewage by Detention Pond)

  • 이종태;송치흥;강태호
    • 한국수자원학회논문집
    • /
    • 제33권3호
    • /
    • pp.351-364
    • /
    • 2000
  • 본 연구에서는 저류지에 의한 우수의 수질개선 효과를 모형실험에 의하여 분석하였다. 본 연구를 통하여 배수구역 출구에 저류지를 설치함으로써 합류식 관거를 통한 하수 및 강우 초기 유출수의 첨두유량과 오염도를 크게 경감시킬 수 있음을 확인하였다. 저류조 모형실험은 자연침강 저류조와 자갈접촉 저류조에 대하여 각각 실시하였다. 자연침강 저류조실험에서는 지속적으로 우수한 방류하는 경우보다는 일정시간 저류지내에 정체 후 방류하는 경우가 동일한 지체시간의 조건하에서 더 높은 오염물질 제거율을 보였다. 또한, 자갈을 채운 저류조에 대한 실험을 실시하였으며, 자연침강 저류조에 비해 전반적으로 각 오염성분에 대해 높은 제거율을 보였다. 한편, 채움재료의 표면이 상대적으로 거친 쇄석의 경우가 자갈보다 높은 제거율을 보였다.

  • PDF

개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구 (A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems)

  • 박병학;전원탁;이보현;이강근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권4호
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.

하천수를 정화하는 갈대습지의 개수부에 의한 질소제거 비교 (Comparison of Nitrogen Removal in Reed Wetlands with and Without Open Water Purifying Effluent from a Treatment Pond)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권1호
    • /
    • pp.37-44
    • /
    • 2005
  • Nitrate($NO_3-N$) and total nitrogen(TN) removal by a reed wetland with open water(Wetland 1) was compared with that of a reed wetland without open water(Wetland 2) from March to October 2002. The two wetlands were 25mL by 6mW. An open water area, 3mL by 6mW was designed at the middle of Wetland 1. Reeds(Phragmites australis) were transplanted into the wetlands in June 2000. Water of Sinyang Stream flowing into the Kohung Estuarine Lake located in the southern part of Korea was pumped into a primary treatment pond, whose effluent was discharged into the secondary pond. Effluent from the secondary pond was funneled into the wetlands. Inflow into the wetlands averaged about 20.0$m^3$/day and their hydraulic retention time was approximately 1.5 days. Average $NO_3-N$ removal by Wetland 1 was 117.61mg/$m^2{\cdot}day$ and that by Wetland 2 was 106.39mg/$m^2{\cdot}day$. $NO_3-N$ removal efficiency of Wetland 1 and 2 was 37% and 34%, respectively. TN removal by Wetlands 1 and 2 averaged 226.80 and 214.54mg/$m^2{\cdot}day$, respectively. TN abatement efficiency of Wetland 1 was 43% and that of Wetland 2 was 40%. $NO_3-N$ removal efficiency of Wetland 1 was significantly higher(p=0.038) than Wetland 2. TN removal efficiency of Wetland 1 was also significantly higher(p=0.044) than Wetland 2. The wetland with open water was more efficient for removal of $NO_3-N$ and TN than one without.

Multi-objective Harmony Search 알고리즘을 이용한 상수도 관망 다목적 최적설계 (Optimal Design of Water Supply System using Multi-objective Harmony Search Algorithm)

  • 최영환;이호민;유도근;김중훈
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.293-303
    • /
    • 2015
  • Optimal design of the water supply pipe network aims to minimize construction cost while satisfying the required hydraulic constraints such as the minimum and maximum pressures, and velocity. Since considering one single design factor (i.e., cost) is very vulnerable for including future conditions and cannot satisfy operator's needs, various design factors should be considered. Hence, this study presents three kinds of design factors (i.e., minimizing construction cost, maximizing reliability, and surplus head) to perform multi-objective optimization design. Harmony Search (HS) Algorithm is used as an optimization technique. As well-known benchmark networks, Hanoi network and Gyeonggi-do P city real world network are used to verify the applicability of the proposed model. In addition, the proposed multi-objective model is also applied to a real water distribution networks and the optimization results were statistically analyzed. The results of the optimal design for the benchmark and real networks indicated much better performance compared to those of existing designs and the other approach (i.e., Genetic Algorithm) in terms of cost and reliability, cost, and surplus head. As a result, this study is expected to contribute for the efficient design of water distribution networks.

와이블 분포를 이용한 다기능 다중상태 대기시스템의 신뢰도 분석 (Reliability Analysis of Multi-functional Multi-state Standby System Using Weibull Distribution)

  • 김지혜;정영배
    • 산업경영시스템학회지
    • /
    • 제40권3호
    • /
    • pp.138-147
    • /
    • 2017
  • As the functions and structure of the system are complicated and elaborated, various types of structures are emerging to increase reliability in order to cope with a system requiring higher reliability. Among these, standby systems with standby components for each major component are mainly used in aircraft or power plants requiring high reliability. In this study, we consider a standby system with a multi-functional standby component in which one standby component simultaneously performs the functions of several major components. The structure of a parallel system with multifunctional standby components can also be seen in real aircraft hydraulic pump systems and is very efficient in terms of weight, space, and cost as compared to a basic standby system. All components of the system have complete operation, complete failure, only two states, and the system has multiple states depending on the state of the component. At this time, the multi-functional standby component is assumed to be in a non-operating standby state (Cold Standby) when the main component fails. In addition, the failure rate of each part follows the Weibull distribution which can be expressed as increasing type, constant type, and decreasing type according to the shape parameter. If the Weibull distribution is used, it can be applied to various environments in a realistic manner compared to the exponential distribution that can be reflected only when the failure rate is constant. In this paper, Markov chain analysis method is applied to evaluate the reliability of multi-functional multi-state standby system. In order to verify the validity of the reliability, a graph was generated by applying arbitrary shape parameters and scale parameter values through Excel. In order to analyze the effect of multi-functional multi-state standby system using Weibull distribution, we compared the reliability based on the most basic parallel system and the standby system.

Experimental Investigation of Local Half-cone Scouring Against Dam under the Effect of Localized Vibrations in the Sediment Layers

  • Dodaran, Asgar Ahadpour;Park, Sang Kil;Mardashti, Asadollah;Noshadi, Mehrzad;Afsari, Mohammad
    • 한국해양공학회지
    • /
    • 제27권2호
    • /
    • pp.107-113
    • /
    • 2013
  • Most natural river reach are approximately balanced with respect to sediment inflow and outflow. Dam construction dramatically alters this balance, creating an impounded river reach characterized by extremely low flow velocities and efficient sediment trapping. The impounded reach will accumulate sediment and lose storage capacity until a balance is again achieved, which would normally occur after the impoundment has become "filled up" with sediment and can no longer provide water storage and other benefits. This paper aims to investigate the sediment removal process in dam reservoir using simultaneously pressure flushing operation and vibrator machine. The main objective of this study is to identify the effect of vibrator in flushing cone dimensions. To achieve the objectives of present study, laboratory test have conducted under different hydraulic conditions such as two bottom outlets with diameter equal to 2" and 3", five discharges 0.23, 0.53, 1.21, 1.53 and 2.1 lit/s and only one water depth above the center of bottom outlets. Using the vibrator machine mounted into the reservoir and close to the bottom outlet, different frequency e.g. 20, 35 and 50 HZ, have been introduced to the deposited sediment at the vicinity of outlet. The results indicate that the volume and width of flushing cone are strongly affected by frequency of vibrations. The results indicate that the volume and width of flushing cone are strongly affected by frequency of vibrations.