• Title/Summary/Keyword: Hydraulic convergence

Search Result 138, Processing Time 0.024 seconds

A Study on the Actuating Device Technology in Guided Weapon System (유도무기체계 구동장치 기술에 관한 연구)

  • Lee, Young-Uk
    • Convergence Security Journal
    • /
    • v.7 no.2
    • /
    • pp.145-154
    • /
    • 2007
  • In this paper, a study on the actuator device technology in guided weapon system development. Hydraulic and pressure, electric motor device had been mostly used, but recently due to high output to weight ratio, pressure actuator device is widely used except for small tactical guided ammunition which needed small power. And now the actuator design concept and technical level is changed because of high mobility of guided ammunition, development of magnetic materials which used new material for requirement of despondence, progress of control and electrodynamics technology, and digitalize and integrity. In this paper we clearly proposed the actuator design criteria and detailed technology development trend for next generation guided weapon system.

  • PDF

A Study for Design of Fuzzy Controller with the Automatic Adjustment of Scale Factors (스케일 계수를 자동조정하는 퍼지제어기 설계에 관한 연구)

  • 이상윤;신위재
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.4
    • /
    • pp.42-48
    • /
    • 2002
  • The case that cannot show the satisfactory control results with a modeling error and a shortage of related knowledge about a plant is if a fuzzy controller designed based on the plant model or the experience applies to an actual plant. We must adjust the scale factor which is a controller again in order to improve control performance in case of this and needs a lot of time and costs because this regulation process is carried out with a trial and error way We proposes the fuzzy controller that an automatic control adjust scale factors according to fuzzy logic and normalizer in this paper We confirmed that an automatic adjusted fuzzy controller displayed good performance than the fuzzy controller that scale factors was fixed through simulation. We implemented the controller using the DSP processor and applied in a hydraulic servo system. And then we observed an experimental results.

  • PDF

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

Research on Air Flow Rate Test Method for Blower System (송풍 시스템의 공기유량측정 방법에 관한 연구)

  • Lee, Jun-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • This study conducted the measurements of air flow rate for blower systems with experiment and numerical. A new airflow rate test method is suggested, with which it is possible to accurate measurements and calculate the air flow rate for blower systems. The blower(axial fan) is an industrial fluid machine device that supplies a large amount of air by driving an impeller with an electric motor, and it is widely used throughout the industry such as steel, power plant, chemical, semiconductor, LC D, food, and cement. The airflow from the blower is for exchanging the heat in the cooling unit or heat exchanger. The temperature of coolants and hydraulic oil primarily depends on the amount of airflow rate through the cooling package so its accurate estimation is very important. Moreover, it required a larger investment in time and cost since it could not be executed until the system is actually made. Therefore, this research is intended to examine the phenomenon of air flow pattern when testing air flow rate, suggested new test method, and show the result of the validation test.

A Study on Dynamics Analysis and Position Control of 5 D.O.F. Multi-joint Manipulater for Uncontact Remote Working (원격작업을 위한 5자유도 다관절 매니퓰레이터의 동특성 분석 및 위치제어에 관한 연구)

  • Kim, Hee-Jin;Jang, Gi-Wong;Kim, Seong-Il;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.87-99
    • /
    • 2022
  • We propoes a study on the dynamic characteristics analysis and position control of 5-degree multi-joint manipulators for untact remote working at construction sites and manufacturing plants. The main frame of freedom multi-joint manipulator consists of five elements, boom cylinder, boom cylinder, arm cylinder, bucket cylinder, and rotation joint and link. In addition, the main purpose of the proposed system is to realize the work of the manufacturing process or construction site by remote control. Motion control of the entire system is a servo valve control method by hydraulic servo cylinders for one to four joints, and a servo motor control method is applied for five joints. The reliability of the proposed method was verified through performance experiments by computer simulation.

A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer (저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구)

  • Park, Taehyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.

A Study on the Multiphase Flow Characteristics in an Mud System (머드시스템의 다상 유동 특성 연구)

  • Lee, Wang-Do;Han, Sang-Mok;Chun, Joong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.737-744
    • /
    • 2021
  • An investigation is conducted to study a solid-liquid mixture vertically upward hydraulic transport of solid particles by non-Newtonian fluids in the Mud system. Rheology of particulate suspensions in viscoelastic fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, etc. In this study a clear acrylic pipe was used in order to observe the movement of solid particles. Annular velocities varied from 0.4 m/s to 1.2 m/s. The mud systems which were utilized included aqueous solution of sodium carboxymethyl cellulose (CMC) solutions. Main parameters considered in the study were inner-pipe rotary speed, fluid flow regime and particle injection rate. Solid volumetric concentration and pressure drops were measured for the various parameters such as inclination angle, flow rate, and rotational speed of inner cylinder.

A Convergency Study on the Gas Turbine Rotation Axis Temperature Sensor for Power Plants (발전소용 가스터빈 회전축 온도 센서 융합연구)

  • Lee, Jeongl-Ick;Na, Gi-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.293-298
    • /
    • 2019
  • The global market for temperature sensors for power plants is estimated at around 35 billion won, of which South Korea relies on imported products for more than 95 percent. This study is that a temperature measurement device for gas turbine rotators for power plants and can be applied to more than 800 of 100 MW gas turbine generators operating in Korea. This study has improved durability by changing the shape of the measuring part, structure of the connecting part, and material changes, and is a component technology applicable to other measuring devices such as humidity, gas and hydraulic pressure used in precision chemical process and plant export industry. As a result of this study, temperature sensors designed as three types of sensors for measuring the temperature of the gas turbine for power plants met Class 1 temperature accuracy in the range of 0℃ to 300℃, and improved durability significantly compared to similar products.

Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis (유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계)

  • Hwang, Gi Ung;Kwak, Hyo Seo;Kim, Jae Yeol;Eom, Tae Jin;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1077-1084
    • /
    • 2017
  • Camshaft engines designed for constant engine loads have been applied to existing marine diesel engines. However, due to environmental regulations, electro-hydraulic servo mechanisms, which have a loaddependent cylinder liner jacket water cooling system (LDCL-JWCS), have been recently developed to individually control the temperature of the cylinders depending on the engine load. In this system, the 3-way valve, which prevents low temperature corrosion by reducing the temperature difference between the upper and lower parts of the cylinder, has been employed, but the outlet mass flow of the existing valve is low. In this study, the design of the internal shape of the 3-way valve was performed by analyzing the effects of the design parameters of the valve shape on the performance (i.e., the outlet mass flow rate and temperature). The proposed model was verified by comparing its performance to that of existing marine diesel engine valves.

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.