• Title/Summary/Keyword: Hydraulic analysis model

Search Result 1,137, Processing Time 0.024 seconds

RC Flat Plate Subject to Combined In-Plane Compressive and Out-of-Plane Floor Loads (면내 압축력 및 면외 바닥하중을 받는 플랫 플레이트 슬래브)

  • Park, Hong-Gun
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.231-242
    • /
    • 1999
  • This paper presents a numerical study on the flat plates in deep basements, subjected to out-of-plane floor load and in-plane compressive load due to soil and hydraulic lateral pressure. For nonlinear finite element analysis, a computer program addressing material and geometric nonlinearities is developed. The validity of the numerical model is established by comparison with existing experiments performed on plates simply supported on four edges. The flat plates to be studied are designed according to the Direct Design Method in Korean Building Code for Structural Concrete. Through numerical study on the effects of different load combinations and loading sequence, the load condition that governs the strength of the flat plates is determined. For the plates under the governing load condition, parametric studies are performed to investigate variations of the strength with reinforcement ratio, aspect ratio, concrete strength, and slenderness ratio. Based on the numerical results, the floor load magnification factor is proposed.

Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis (유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계)

  • Hwang, Gi Ung;Kwak, Hyo Seo;Kim, Jae Yeol;Eom, Tae Jin;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1077-1084
    • /
    • 2017
  • Camshaft engines designed for constant engine loads have been applied to existing marine diesel engines. However, due to environmental regulations, electro-hydraulic servo mechanisms, which have a loaddependent cylinder liner jacket water cooling system (LDCL-JWCS), have been recently developed to individually control the temperature of the cylinders depending on the engine load. In this system, the 3-way valve, which prevents low temperature corrosion by reducing the temperature difference between the upper and lower parts of the cylinder, has been employed, but the outlet mass flow of the existing valve is low. In this study, the design of the internal shape of the 3-way valve was performed by analyzing the effects of the design parameters of the valve shape on the performance (i.e., the outlet mass flow rate and temperature). The proposed model was verified by comparing its performance to that of existing marine diesel engine valves.

An Estimation of Discharge Coefficients with the Variations of Side Weir Shape (횡월류위어의 형상에 따른 유량자수 추정)

  • Song, Jai-Woo;Park, Sung-Sik;Kim, Ji-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.1 s.174
    • /
    • pp.51-62
    • /
    • 2007
  • To estimate more accurately the outflow over a sharp crested side weir, it is necessary to analyze the flow characteristics over side weir and to estimate the discharge coefficient in the weir equation. The purpose of this study is to estimate the discharge coefficients of sharp crested rectangular and triangular side weirs by means of hydraulic model experiments with the variations of upstream Froude number in the main channel and length and apex angle. Experimental results show that the discharge coefficients depend on the shape and geometric conditions of side weir as well as the upstream Froude number in the main channel. Through the multiple regression analysis, formulas of discharge coefficient for rectangular and triangular types are proposed and its applicability is confirmed by comparing estimated and measured discharges over side weirs.

Self-Burial Structure of the Pipeline with a Spoiler on Seabed (해저지반에 설치된 스포일러 부착형 파이프라인의 자가매설 기능분석)

  • Lee, Woo-Dong;Hur, Dong-Soo;Kim, Han-Sol;Jo, Hyo-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.310-319
    • /
    • 2016
  • If a spoiler was attached to the pipeline investigated in a previous study, a strong flow and vortex at the lower part caused scouring and thus an asymmetric pressure distribution, which assisted in the analysis of the self-burial structure where a down force was applied to the pipe. However, only the fluid-pipe interaction was considered, excluding the medium (seabed), when practically burying the pipeline. Thus, this study applied a numerical model (LES-WASS-2D) to directly analyze the non-linear interactions among the fluid, pipe, and seabed in order to perform numerical simulations of a pipeline with a spoiler installed on the seabed. This allowed the self-burial mechanism of a pipeline with a spoiler to be analyzed in the same context as the previous study that considered only the fluid-pipe interaction. However, when a pipeline was installed on the seabed, a strong flow and vortex were found at the front of the bottom, and a spoiler accelerated the fluid resistances. This hydraulic phenomenon will reinforce the scouring and down force on the pipeline. In the general consideration of the numerical analysis results by the specifications and arrangements of the spoiler, a pipeline with a spoiler was found to be the most effective for the self-burial function.

Comparative Analysis of Observation and NWP Data of Downslope Windstorm Cases during 3-Dimensional Meteorological Observation Project in Yeongdong Region of Gangwon province, South Korea in 2020 (2020 강원영동 공동 입체기상관측 기간 강풍 사례에 대한 관측자료와 수치모델 비교 분석)

  • Kwon, Soon-Beom;Park, Se-Taek
    • Atmosphere
    • /
    • v.31 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • In order to investigate downslope windstorm by using more detailed observation, we observed 6 cases at 3 sites - Inje, Yongpyeong, and Bukgangneung - during "3-D Meteorological Observation Project in Yeongdong region of Gangwon province, South Korea in 2020." The results from analysis of the project data were as follows. First, AWS data showed that a subsidence inversion layer appeared in 800~700 hPa on the windward side and 900~850 hPa on the leeward side. Second, before strong wind occurred, the inversion layer had descended to about 880~800 hPa. Third, with mountain wave breaking, downslope wind was intensified at the height of 2~3 km above sea level. After the downslope wind began to descend, the subsidence inversion layer developed. When the subsidence inversion layer got close to the ground, wind peak occurred. In general, UM (Unified Model) GDAPS (Global Data Assimilation Prediction System) have had negative bias in wind speed around peak area of Taebaek mountain range, and positive bias in that of East Sea coast area. The stronger wind blew, the larger the gap between observed and predicted wind speed by GDAPS became. GDAPS predicted strong p-velocity at 0600 LST 25 Apr 2020 (4th case) and weak p-velocity at 2100 LST 01 Jun 2020 (6th case) on the lee-side of Taebaek mountain range near Yangyang. As hydraulic jump theory was proved, which is known as a mechanism of downslope windstorm in Yeongdong region, it was confirmed that there is a relationship between p-velocity of lee-side and wind speed of eastern slope of Taebaek mountain range.

Application and optimal design of the bionic guide vane to improve the safety serve performances of the reactor coolant pump

  • Liu, Haoran;Wang, Xiaofang;Lu, Yeming;Yan, Yongqi;Zhao, Wei;Wu, Xiaocui;Zhang, Zhigang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2491-2509
    • /
    • 2022
  • As an important device in the nuclear island, the nuclear coolant pump can continuously provide power for medium circulation. The vane is one of the stationary parts in the nuclear coolant pump, which is installed between the impeller and the casing. The shape of the vane plays a significant role in the pump's overall performance and stability which are the important indicators during the safety serve process. Hence, the bionic concept is firstly applied into the design process of the vane to improve the performance of the nuclear coolant pump. Taking the scaled high-performance hydraulic model (on a scale of 1:2.5) of the coolant pump as the reference, a united bionic design approach is proposed for the unique structure of the guide vane of the nuclear coolant pump. Then, a new optimization design platform is established to output the optimal bionic vane. Finally, the comparative results and the corresponding mechanism are analyzed. The conclusions can be gotten as: (1) four parameters are introduced to configure the shape of the bionic blade, the significance of each parameter is herein demonstrated; (2) the optimal bionic vane is successfully obtained by the optimization design platform, the efficiency performance and the head performance of which can be improved by 1.6% and 1.27% respectively; (3) when compared to the original vane, the optimized bionic vane can improve the inner flow characteristics, namely, it can reduce the flow loss and decrease the pressure pulsation amplitude; (4) through the mechanism analysis, it can be found out that the bionic structure can induce the spanwise velocity and the vortices, which can reduce drag and suppress the boundary layer separation.

Seepage Characteristics of Domestic Bed Sediments Mixed with Good-quality Soil as Levee Fill Material (양질토와 혼합처리된 국내 하상토의 제체재료로서의 침투특성)

  • Choi, Bong-Hyuck;Kim, Kyung-Min;Kim, Jin-Man;Lee, Dae-Yeong
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.105-111
    • /
    • 2008
  • To improve the stability of levee structure, it is required to use good quality fill materials, intensive management, appropriate hydraulic structure and construction of cut-off wall. In particular, the most important factor of levee construction technology is to use bed sediment for its safety. In this study, seepage model test and numerical analysis were performed based on a standard section of levee recommended in the river design standard of korea (2005). The results of test and analysis show that most of the bed soil is a sand (SP in USCS), which does not satisfy the permeability criteria for levee materials ($< k=10^{-3}cm/sec$), thus for the safety of levee it is required to adopt a stabilizing method such as good quality soil mixing, water content control.

Experimental Analysis of Nodal Head-outflow Relationship Using a Model Water Supply Network for Pressure Driven Analysis of Water Distribution System (상수관망 압력기반 수리해석을 위한 모의 실험시설 기반 절점의 압력-유량 관계 분석)

  • Chang, Dongeil;Kang, Kihoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.421-428
    • /
    • 2014
  • For the analysis of water supply network, demand-driven and pressure-driven analysis methods have been proposed. Of the two methods, demand-driven analysis (DDA) can only be used in a normal operation condition to evaluate hydraulic status of a pipe network. Under abnormal conditions, i.e., unexpected pipe destruction, or abnormal low pressure conditions, pressure-driven analysis (PDA) method should be used to estimate the suppliable flowrate at each node in a network. In order to carry out the pressure-driven analysis, head-outflow relationship (HOR), which estimates flowrate at a certain pressure at each node, should be first determined. Most previous studies empirically suggested that each node possesses its own characteristic head-outflow relationship, which, therefore, requires verification by using actual field data for proper application in PDA modeling. In this study, a model pipe network was constructed, and various operation scenarios of normal and abnormal conditions, which cannot be realized in real pipe networks, were established. Using the model network, data on pressure and flowrate at each node were obtained at each operation condition. Using the data obtained, previously proposed HOR equations were evaluated. In addition, head-outflow relationship at each node was analyzed especially under multiple pipe destruction events. By analyzing the experimental data obtained from the model network, it was found that flowrate reduction corresponding to a certain pressure drop (by pipe destruction at one or multiple points on the network) followed intrinsic head-outflow relationship of each node. By comparing the experimentally obtained head-outflow relationship with various HOR equations proposed by previous studies, the one proposed by Wagner et al. showed the best agreement with the exponential parameter, m of 3.0.

Bivariate regional frequency analysis of extreme rainfalls in Korea (이변량 지역빈도해석을 이용한 우리나라 극한 강우 분석)

  • Shin, Ju-Young;Jeong, Changsam;Ahn, Hyunjun;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.9
    • /
    • pp.747-759
    • /
    • 2018
  • Multivariate regional frequency analysis has advantages of regional and multivariate framework as adopting a large number of regional dataset and modeling phenomena that cannot be considered in the univariate frequency analysis. To the best of our knowledge, the multivariate regional frequency analysis has not been employed for hydrological variables in South Korea. Applicability of the multivariate regional frequency analysis should be investigated for the hydrological variable in South Korea in order to improve our capacity to model the hydrological variables. The current study focused on estimating parameters of regional copula and regional marginal models, selecting the most appropriate distribution models, and estimating regional multivariate growth curve in the multivariate regional frequency analysis. Annual maximum rainfall and duration data observed at 71 stations were used for the analysis. The results of the current study indicate that Frank and Gumbel copula models were selected as the most appropriate regional copula models for the employed regions. Several distributions, e.g. Gumbel and log-normal, were the representative regional marginal models. Based on relative root mean square error of the quantile growth curves, the multivariate regional frequency analysis provided more stable and accurate quantiles than the multivariate at-site frequency analysis, especially for long return periods. Application of regional frequency analysis in bivariate rainfall-duration analysis can provide more stable quantile estimation for hydraulic infrastructure design criteria and accurate modelling of rainfall-duration relationship.

A Study on the Model Test for Pneumatic Mine-Filling (공압식 갱내충전을 위한 모형실험 연구)

  • Yang, In-Jae;Shin, Dong-Choon;Yoon, Byung-Sik;Mok, Jin-Ho;Kim, Hak-Sung;Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.449-463
    • /
    • 2014
  • There are many case studies and application cases in abandoned mines for hydraulic filling method filled by slurry or paste form, but research on the pneumatic filling is not applied in Korea. The damage of steel pipe is occurred by wear due to the flow of filling material in the bent area of steel pipe in traditional pneumatic filling method. In this study, the new pneumatic filling method was developed using a newly devised improved nozzle to improve the above problem. The model test for mine filling was performed in the laboratory for the simulated accessible or inaccessible mine cavities, and the filling efficiency by the results obtained from the test was calculated. The filling efficiency was analyzed from the variation of outlet angle, feed rate and grain size of sand in model test of simulated accessible mine cavity. The superiority of improved pneumatic filling method was proved through the analysis of filling efficiency by the results obtained from each model tests of gravitational, traditional, and improved filling method in simulated inaccessible mine cavity.