• 제목/요약/키워드: Hydraulic Pump Control System

검색결과 160건 처리시간 0.019초

소형 굴삭기용 브리드 오프 센터형 유압 제어 시스템의 특성 (The Characteristic of the Hydraulic Control System with Bleed-off Center Type of a Compact Excavator)

  • 김준식;이승현;이재원
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.119-126
    • /
    • 2008
  • In this study, the characteristics of the hydraulic control system with bleed-off center type of a compact excavator were analyzed using developed analysis program. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the performance improvement of a hydraulic control system of a compact excavator.

폐루프 유압 에너지 회생 시스템에 관한 연구 (Design and Assessments of a Closed-loop Hydraulic Energy-Regenerative System)

  • 호 치엣 흥;윤종일;안경관
    • 유공압시스템학회:학술대회논문집
    • /
    • 유공압시스템학회 2010년도 춘계학술대회
    • /
    • pp.116-125
    • /
    • 2010
  • In this study, a novel hydraulic energy-regenerative system was presented from its proposal through its modeling to its control. The system was based on a closed-loop hydrostatic transmission and used a hydraulic accumulator as the energy storage system in a novel configuration to recover the kinetic energy without any reversion of the fluid flow. The displacement variation in the secondary unit was reduced, which widened the uses of several types of hydraulic pump/motors for the secondary unit. The proposed system was modeled based on its physical attributes. Simulation and experiments were performed to evaluate the validity of the employed mathematical model and the energy recovery potential of the system. The experimental results indicated that the round trip recovery efficiency varied from 22% to 59% for the test bench.

  • PDF

두 개의 EPPR 밸브가 적용된 정/역 가변형 사판식 액셜 피스톤 펌프 시스템 모델링 (System Modeling of a Bi-directional Outlet Variable Swash Plate Type Axial Piston Pump with Two EPPR Valves)

  • 김용길;김수태;함영복;윤소남;손호연
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권1호
    • /
    • pp.51-60
    • /
    • 2020
  • This study addresses the modeling of a bi-directional outlet variable swash plate type axial piston pump with two EPPR valves and an analysis of the response characteristics to the angle control of that pump. In this paper, the combination of the EPPR valve and double rod type piston is referred to as the EPPR regulator. The EPPR regulator is compact and inexpensive, and has good responsiveness. Under actual pump operating conditions, because of the various external conditions of the pump, inertia is applied to the swash plate, generating the tilting torque. Also, the tilting torque can delay or shorten the response characteristics of the regulator. So we validated them through the analysis using SimulationX and these results allow users to freely integrate the EPPR regulator into the desired system.

수중발사를 위한 ATP 방식 압축수 방출시스템의 동특성 해석 (Analysis of the Dynamic Characteristics of Pressurized Water Discharging System for Underwater Launch using ATP)

  • 한명철;김정관;김광수
    • 제어로봇시스템학회논문지
    • /
    • 제15권6호
    • /
    • pp.567-572
    • /
    • 2009
  • The underwater launch system using an ATP consists of five parts: compressor tank, proportional flow control servo valve, expulsion spool valve, air turbine pump, and discharge tube. The purpose of this study is to develop an underwater launch system using an ATP and to verify the validity of the system. The proportional flow control servo valve is modeled as a 2nd order transfer function. The projectile is ejected by pressurized water through the air turbine pump, which is controlled by expulsion valve. The mathematical model is derived to estimate the dynamic characteristics of the system, and the important design parameters are derived by using simulations. The computer simulation results show the dynamic characteristics and the possibility of control for underwater launch system.

편로드 유압시스템의 강인 위치제어에 관한 연구 (A Study on the Robust Position Control of Single-rod Hydraulic System)

  • 조택동;서송호;양상민
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.128-135
    • /
    • 1999
  • A driving simulators of aircraft and vehicle may consist of hydraulic power systems with many single-rod cylinders. The single-rod hydraulic systems are convenient but need more robust control scheme in order to achieve a reliable performance against the wide range of operating disturbances and the inherent model uncertainties. $H_{\infty}$ control scheme was implemented to the 2 degree-of-freedom hydraulic device similar to the simple driving simulator. With the reasonable disturbances from sensor, base and pump and also with the linearization of model, the simulation and experimental results showed good agreements.

  • PDF

차량 능동현가장치용 유압 제어시스템의 동적거동 해석 (Dynamic Behaviour Analysis of a Hydraulic Control System for Vehicle Active Suspension)

  • 정용길;이일영
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.51-59
    • /
    • 2000
  • Active suspension systems have been using for improving ride quality and stability for vehicles. An active suspension system is composed of a hydraulic pump, pressure control valves, hydraulic dampers, vehicle body, tires and other components. In this study, the mathematical model for the active suspension system based on the quarter car concept is derived, and a program for analysing the dynamic behaviour of the suspension system is developed. The computed results by the developed program are compared with the experimental results for confirming the reliability and usefulness of the developed program.

  • PDF

A minimum energy control of a load-sensing hydraulic servo system

  • Kim, S.D.;Cho, H.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.747-752
    • /
    • 1987
  • The dynamic characteristics of a load-sensing hydraulic servo system are complex and highly unstable. Another property of the system is that the setting value of pump compensator is closely related to energy efficiency as well as control performance of the system. This necessitates the development of an effective control algorithm which guarantees good control performance, stability and energy efficiency. This paper considers a suboptimal PID control for the velocity control problem of the load-sensing hydraulic servo system. The results of simulations studies and experiments show that the proposed suboptimal controller can produce much better control performance than nonoptimal controllers and give effective energy efficiency.

  • PDF

외란을 갖는 전기유압 서보시스템의 위치제어 (Position Control of an Electro-hydraulic Servo System with Disturbance)

  • 허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권3호
    • /
    • pp.1-7
    • /
    • 2021
  • In a hydraulic control system, since a hydraulic cylinder drives a relatively large mass of an object, an external load force acts as a disturbance on the control performance of the system. Additionally, as the hydraulic system is used for a long period, there are disturbances that occur gradually, such as a drop in supply pressure because of abrasion of the pump, oil leakage from a valve, and oil leakage from a cylinder. In this study, a state feedback controller based on a linearization technique is applied. To prevent the performance degradation of the controller from the load disturbance, an Extended Luenberger observer (ELO) is used for the Extended system. The case of using the proportional controller, which is a representative linear controller, and the result of using the controller designed in this study are compared and reviewed through simulation. Also, we propose an experimental gain-setting method for a state feedback controller that can be used at industrial sites, and examine how the stability and control performance of the system changes because of the disturbance inputs through the experimental results.

콘크리트 펌프트럭의 코어펌프 해석모델개발 및 신뢰성 검토 (Development of a Concrete Pump Truck's Core Pump Model and Its Validation)

  • 박성수;노대경;이근호;이대희;장주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권2호
    • /
    • pp.1-8
    • /
    • 2018
  • This study is a first step toward reducing surge pressure, and it has another purpose, which is to developing an analysis model which can closely analyze a hydraulic circuit and be used in design. For development of analysis model, SimulationX, a commercial program, is used. The study progress methods are as follows. By analyzing the structure and operating mechanisms of each part of the hydraulic system of the pump truck and referring its parameters, develop a single component model. Assemble the developed single component model, and make an overall analysis the model. By comparing the similarities between the developed model and the actual system's test results, validate the reliability of the analysis model.

가변 용적형 사판식 피스톤 펌프의 회전 속도 조절에 의한 정압 제어 소비 동력 절감 (Reduction of Power Consumption for Constant Pressure Control of Variable Swash Plate-type Piston Pump by Varying the Pump Speed)

  • 김종혁;홍예선
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.53-60
    • /
    • 2014
  • This paper proposes a control scheme to reduce the power consumption of a variable displacement swash-plate type piston pump supplying oil to a valve-controlled hydraulic cylinder at constant pressure. Whenever flow rate demand was absent, the swash plate angle and the pump speed were changed to the minimum values required to compensate for the internal leakage flow. In response to command signals, the pump speed was changed in proportion to the absolute mean value of the speed component for position commands. At the same time, a pressure regulator was activated to maintain constant system pressure by precisely adjusting the pump speed with the swash plate angle fixed at the maximum. The conventional system consisting of a pressure-compensated variable displacement type pump is driven at a constant speed of 1,800rpm. By comparison, computer simulation and experimental results showed that idling power at stand-by status could be reduced by up to 70% by reducing the pump speed from 1,800rpm to 300rpm and the swash plate angle to the minimum.