• Title/Summary/Keyword: Hydraulic Power Unit

Search Result 97, Processing Time 0.031 seconds

Development of the Linear Piston Pump Driven by the Hydraulic Power for the Solid Transferring (고형물 이송을 위한 유압구동 선형 피스톤 펌프의 개발)

  • Kim, Bong-Hwan;Ahn, Kook-Chan;Chung, Sung-Won;Kim, Young-Hoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.82-89
    • /
    • 2009
  • The purpose of this study is to investigate the actual field application of the linear piston pump for the solid transferring driven by the hydraulic power unit. In this paper, the numerical analysis and performance evaluating experiments were performed. CFX program has been used to obtain the solutions for the problems of three-dimensional, turbulent water flow in the linear piston pump. The velocity and the pressure distributions are obtained using the turbulent $k-\varepsilon$ model. To evaluate the performance of the linear piston pump, the performance test stand and data acquisition system were manufactured. The numerical predictions agree favorably with experimental results within 7% error. Speed of the piston which is satisfied the flow rate 3,000l/min which considers from basic design became 0.33m/s. This paper could be applied to the design of the linear piston pump for the fish transferring.

  • PDF

Comparisons of Linear Characteristic for Shape of Stator Teeth of Hall Effect Torque Sensor

  • Lee, Boram;Kim, Young Sun;Park, Il Han
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.285-290
    • /
    • 2012
  • Electric Power Steering (EPS) system is superior to conventional Hydraulic Power Steering (HPS) system in aspect of fuel economy and environmental concerns. The EPS system consists of torque sensor, electric motor, ECU (Electric Control Unit), gears and etc. Among the elements, the torque sensor is one of the core technologies of which output signal is used for main input of EPS controller. Usually, the torque sensor has used torsion bar to transform torsion angle into torque and needs linear characteristic in terms of flux variation with respect to rotation angle of permanent magnet. The torsion angle of both ends of a torsion bar is measured by a contact variable resistor. In this paper, the sensor is accurately analyzed using 3D finite element method and its characteristics with respect to four different shapes of the stator teeth are compared. The four shapes are rectangular, triangular, trapezoidal and circular type.

The development of turbine valve actuator efficiency analysis system for the standard power plants (표준형 발전소용 터빈 밸브 작동기 성능 분석 시스템 개발)

  • Roh, J.H.;Kim, S.H.;Lee, D.I.;Yang, C.K.;Shin, Y.Y.;Jung, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.537-541
    • /
    • 2002
  • This paper is about the development of the turbine valve actuator efficiency analysis system for the standard power plants. We developed hydraulic power unit and turbine valve actuator controller. We designed control algorithm for turbine valve actuator, implemented and verified it at the industrial plants.

  • PDF

Dynamic Simulation of Pump-Storage Power Plants with different variable speed configurations using the Simsen Tool

  • Kruger, Klaus;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.334-345
    • /
    • 2009
  • Pumped storage power plants are playing a significant role in the contribution to the stabilization of an electrical grid, above all by stable operation and fast reaction to sudden load respectively frequency changes. Optimized efficiency and smooth running characteristics both in pump and turbine operation, improved stability for synchronization in turbine mode, load control in pump mode operation and also short reaction times may be achieved using adjustable speed power units. Such variable speed power plants are applicable for high variations of head (e.g. important for low head pump-turbine projects). Due to the rapid development of power semiconductors and frequency converter technology, feasible solutions can be provided even for large hydro power units. Suitable control strategies as well as clear design criteria contribute significantly to the optimal usage of the pump turbine and motor-generators. The SIMSEN tool for dynamic simulations has been used for comparative investigations of different configurations regarding the power converter topology, types of semiconductors and types of motor-generators including the coupling to the hydraulic system. A brief overview of the advantages & disadvantages of the different solutions can also be found in this paper. Using this approach, a customized solution minimizing cost and exploiting the maximum usage of the pump-turbine unit can be developed in the planning stage of new and modernization pump storage projects.

Comprehensive Vibration Assessment Program for Yonggwang Nuclear Power Plant Unit 4

  • Huinam Rhee;Hwang, Jong-Keun;Kim, Tae-Hyung;Kim, Jung-Kyu;Song, Heuy-Gap;Kim, Beom-Shig
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.1001-1007
    • /
    • 1995
  • A Comprehensive Vibration Assessment Program (CVAP) has been performed for Yonggwang Nuclear Power Plant Unit 4 (YGN 4) in order to verify the structural integrity of the reactor internals for flow induced vibrations prior to commercial operation. The theoretical evidence for the structural integrity of the reactor internals and the basis for measurement and inspection are provided by the analysis. Flow induced hydraulic loads and reactor internals vibration response data were measured during pre-core hot functional testing in YGN 4 site. Also, the critical areas in the reactor internals were inspected visually to check any existence of structural abnormality before and after the pre-core hot functional testing. Then, the measured data have been analyzed and compared with the predicted data by analysis. The measured stresses are less than the predicted values and the allowable limits. It is concluded that the vibration response of the reactor internals due to the flow induced vibration under normal operation is acceptable for long term operation.

  • PDF

3D FE Analysis of Hall Effect Torque Sensor and Shape Design of Its Stator teeth (홀소자 토크센서의 3차원 유한요소해석 및 고정자 치 형상설계)

  • Lee, Bo-Ram;Kim, Young-Sun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.702_703
    • /
    • 2009
  • Electric Power Steering(EPS) system is superior to conventional Hydraulic Power Steering(HPS) system in aspect of fuel economy and environmental concerns. The EPS system consists of torque sensor, electric motor, ECU(Electric Control Unit), gears and etc. Among the elements, the torque sensor is one of the core technologies of which output signal is used for main input of EPS controller. Usually, the torque sensor has used torsion bar to transform torsion angle into torque. The torsion angle of both ends of a torsion bar is measured by a contact variable resistor. In this paper, the sensor is accurately analyzed using 3D finite element method and its characteristics with respect to four different shapes of the stator teeth are compared. The four shapes are rectangular, triangular, trapezoidal and circular type.

  • PDF

Improved prediction of Pump Turbine Dynamic Behavior using a Thoma number dependent Hill Chart and Site Measurements

  • Manderla, Maximilian;Kiniger, Karl N.;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.63-72
    • /
    • 2015
  • Water hammer phenomena are important issues for the design and the operation of hydro power plants. Especially, if several reversible pump-turbines are coupled hydraulically there may be strong unit interactions. The precise prediction of all relevant transients is challenging. Regarding a recent pump-storage project, dynamic measurements motivate an improved turbine modeling approach making use of a Thoma number dependency. The proposed method is validated for several transient scenarios and turns out to improve correlation between measurement and simulation results significantly. Starting from simple scenarios, this allows better prediction of more complex transients. By applying a fully automated simulation procedure broad operating ranges of the highly nonlinear system can be covered providing a consistent insight into the plant dynamics. This finally allows the optimization of the closing strategy and hence the overall power plant performance.

Non-Integrated Standalone Test of An Nuclear Steam Supply System Thermal-Hydraulic Program for the Westinghouse Type Nuclear Power Plant Simulator Using A Best-Estimate Code (최적 계통분석 코드를 이용한 웨스팅하우스형 원자력발전소 시뮬레이터용 핵 증기 공급 계통 열수력 프로그램 독자평가 및 시험)

  • 서인용;이명수;이용관;서재승;권순일
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2004.05a
    • /
    • pp.101-108
    • /
    • 2004
  • KEPRI has developed an Nuclear Steam Supply System(NSSS) thermal-hydraulics simulation program (called ARTS-KORI), based on the best-estimate system code, RETRAN, as a part of the development project for the KORI unit 1 Nuclear Power Plant Simulator. A number of code modifications, such as simplifications and removing of discontinuities of the physical correlations, were made in order to change the RETRAN code as an nuclear Steam Supply System thermal-hydraulics engine in the simulator. Some simplified models and a backup system were also developed. This paper briefly presents the results of non-integrated standalone test of ARTS-KORI.

  • PDF

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer (저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구)

  • Park, Taehyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.