• Title/Summary/Keyword: Hydrant

Search Result 43, Processing Time 0.023 seconds

A Study of the Using Pattern of the Bathroom Shown in the Rural Apartment Houses (농촌공동주택(農村共同住宅) 욕실공간(浴室空間)의 이용(利用) 행태(行態) 연구(硏究))

  • Cho, Il-Howan;Choi, Hyo-Seung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.1 no.1
    • /
    • pp.129-138
    • /
    • 1999
  • The aim of this study is to obtain new design factors which can be applied to the constructing design of bathrooms. This study was especially focused on the using patterns of the bathrooms of the rural apartment houses in Chungbuk Province which have been constructed by the public program to improve old farm houses. To carry out this study, field study, questionnaire survey and personal interview have been made. The results are as follows. 1) It is essential to lay out a bathtub, because farmers need to relieve their fatigue caused by manual labor, and mostly they don't find a bathhouse in the neighborhood. 2) With the drainage way, it is necessary to equip an apparatus to collect and remove the fallen hair and garbage which usually stop up the beak. 3) Considering the using patterns of the bathrooms as the place of washing one's face, foot, hair and clothes, one more hydrant is needed in the bathroom besides the two hydrants in the washstand and bathtub.

  • PDF

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

Impact assessment for water pressure and turbidity occurrence by changes in water flow rate of large consumer at water distribution networks (상수도관망에서 대수용가의 유량변화에 따른 수압 및 탁도발생 영향평가)

  • Choi, Doo Yong;Kim, Ju-Hwan;Choi, Min-Ah;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.277-286
    • /
    • 2014
  • Water discolouration and increased turbidity in the local water service distribution network occurred from hydraulic incidents such as drastic changes of flow and pressure at large consumer. Hydraulic incidents impose extra shear stresses on sediment layers in the network, leading to particle resuspension. Therefore, real time measuring instruments were installed for monitoring the variation of water flow, pressure, turbidity and particulates on a hydrant in front of the inlet point of large apartment complex. In this study, it is attempted to establish a more stable water supply plan and to reduce complaints from customers about water quality in a district metering area. To reduce red or black water, the water flow monitoring and control systems are desperately needed in the point of the larger consumers.

Determination of Optimal Pressure Monitoring Locations of Water Distribution Systems Using Entropy Theory and Genetic Algorithm (엔트로피 이론과 유전자 알고리즘을 결합한 상수관망의 최적 압력 계측위치 결정)

  • Chang, Dong-Eil;Ha, Keum-Ryul;Jun, Hwan-Don;Kang, Ki-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • The purpose of water distribution system is supplying water to users by maintaining appropriate pressure and water quality. For efficient monitoring of the water distribution system, determination of optimal locations for pressure monitoring is essential. In this study, entropy theory was applied to determine the optimal locations for pressure monitoring. The entropy which is defined as the amount of information was calculated from the pressure change due to the variation of demand reflected the abnormal conditions at nodes, and the emitter function (fire hydrant) was used to reproduce actual pressure change pattern in EPANET. The optimal combination of monitoring points for pressure detection was determined by selecting the nodes receiving maximum information from other nodes using genetic algorithm. The Ozger's and a real network were evaluated using the proposed model. From the results, it was found that the entropy theory can provide general guideline to select the locations of pressure sensors installation for optimal design and monitoring of the water distribution systems. During decision-making phase, optimal combination of monitoring points can be selected by comparing total amount of information at each point especially when there are some constraints of installation such as limitation of available budget.

A Study on the Basic Ideas for Fire Fighting Prevention System in Traditional Folk Village - Focused on Oeam Folk Village in Asan - (전통민속마을 소방방재 기본구상 - 아산 외암민속마을을 중심으로 -)

  • Lee, Jeong-Soo;Lee, Wang-Kee;Oh, Kyu-Hyung;Shin, Kyo-Young;Kwon, Heung-Soon
    • Journal of architectural history
    • /
    • v.19 no.1
    • /
    • pp.71-90
    • /
    • 2010
  • This research has set up the fire protection and early suppression plan for Asan Oeam folk village which is composed of traditional wooden building instinct or complex. The results of this study are as follows. 1. The traditional wooden buildings require attentive considerations about the fire property of the Waga and the straw roofed house. Especially, as the straw roofed house has property that the transfer and development of the fire is fast. Therefore we studied on the transferring possibilities of the fire dangerous instinct through measuring the distance from of the eaves edge and trees in neighboring house. 2. This research proposes the tools for the priority protective building through consideration of fire risk and cultural priority because the fire prevention for all is impossible at the same time. 3. The most important thing is preserve the cultural identities of traditional folk village in establishing the fire hydrant and fire prevention facilities. Traditional folk village landscape should be considered.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

Development of Android application based on Walki-talkie and hydrant location information provided to improve the efficiency of the firefighters work. (소방관 업무의 효율성 향상을 위한 안드로이드 기반의 무전기 기능 및 소화전 위치정보를 제공 어플리케이션 개발)

  • Kim, JiHee;Kim, SongA;Baek, SiYoung;Lee, SuKyung;Szadkowski, Krystian Tomasz;Baek, Tae-San
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.310-312
    • /
    • 2014
  • 현재 대구시 소방관들은 소화전, 위험물들의 위치가 모바일 어플리케이션화 되어있지 않다. 이로 인해 관리 및 화재시 현장에 나갈 때 바로 검색할 수 없기 때문에 어려움을 겪고 있다. 본 논문에서는 소화전과 위험물의 모든 정보를 제공하는 모바일 어플리케이션을 통하여 언제 어디서나 소화전과 위험물의 위치와 정보에 접근할 수 있게 하였다. 이와 함께 현재 소방대원들이 사용하는 무전기외 간섭, 끊김, 차단등과 같은 문제점을 개선하기 위하여 기존의 무전기가 사용하던 주파수대역보다 안정되고 좋은 품질의 Wi-FI 통신망을 이용하여 높은 통화품질의 모바일 단말기 기반의 무전통신 서비스를 제공한다.

Smart Fire Fighting Appliances Monitoring System using GS1 based on Big Data Analytics Platform (GS1을 활용한 빅데이터 분석 플랫폼 기반의 스마트 소화기구 모니터링 시스템)

  • Park, Heum
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.57-68
    • /
    • 2018
  • This paper presents a smart firefighting appliances monitoring system based on big data analytics platform using GS1 for Smart City. Typical firefighting appliances are fire hydrant, fire extinguisher, fire alarm, sprinkler, fire engine, etc. for the fire of classes A/B/C/D/E. Among them, the dry chemical fire extinguisher have been widely supplied and 6 millions ones were replaced for the aging ones over 10 years in the past year. However, only 5% of them have been collected for recycling of chemical materials included the heavy metals of environment pollution. Therefore, we considered the trace of firefighting appliances from production to disposal for the public open service. In the paper, we suggest 1) a smart firefighting appliances system using GS1, 2) a big data analytics platform and 3) a public open service and visualization with the analyzed information, for fire extinguishers from production to disposal. It can give the information and the visualized diagrams with the analyzed data through the public open service and the free Apps.

A Study on the State of Utilizing Fire Facility in Fire Fighting (소방시설의 화재진압 활용실태에 관한 연구)

  • Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.144-148
    • /
    • 2011
  • In this study I investigated that fire fighters utilize fire facilities properly or not, and found problems and solutions with interview and questionnaire. Fire fighters tend to utilize portable instruments. 62% of fire fighters have used fire facilities which is installed in building. The most useful facility is indoor fire hydrant, 42% of fire fighters have used that. The primary reason to avoid to use facility is that they think the facilities are not good at quick response. Almost fire fighters want improvement to enhance utilizing fire facilities. Finally in the fire scene, commander's initiative, fire fighter's ability, easiness of utilizing fire facilities, and fire fighter's creditibility about fire facilities are related to the degree of utilizing fire facilities.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.