• 제목/요약/키워드: Hybrid-power

검색결과 2,333건 처리시간 0.033초

풍력.태양광 복합 발전 시스템 개발 및 모니터링에 관한 연구 (The study for developing Wind and Photovoltaic power hybrid generation system and monitoring)

  • 박근현;강철웅;임종환;박의장
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.183.1-183.1
    • /
    • 2010
  • Recently, the increased interest in environmental issues has led to extensive research for development of green energy generation systems. However, only one type of generation system may not be sufficient for stand-alone mode because it cannot cope with the irregularity of weather condition. A hybrid generation system is able to make up for the weakness of each system. In this paper, a stand-alone hybrid wind/PV system is developed that can guarantee the stable energy supply. The system is suitable for power supply under 50W, and a vertical savonius type of blade was designed and applied for the wind generation system.

  • PDF

Efficient Hybrid ARQ schemes for Wireless Communication Systems

  • Ryoo, Sun-Heui;Kim, Soo-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.342-345
    • /
    • 2004
  • An efficient hybrid ARQ scheme based on the rate compatible block turbo codes has been proposed, and its performance has been analyzed. System efficiency is improved by means of adaptive rate code transmission using channel information, trading off bit rate for channel codes, with resulting energy saving. The rate adaptation scheme improves power efficiency while keeping packet delay minimized. On the other hand, power dependant strategies reduce power consumption. Simulation results show that the benefits obtained are very encouraging. The modified hybrid ARQ schemes with the channel information and efficient retransmission structures highly improve the throughput performance in the satellite communication system. Therefore, proposed schemes could be used in future communication systems.

  • PDF

Performance Analysis of SOFC/MGT Hybrid System

  • Kim, Jae-Hwan;Suzuki, Kenjiro
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.703-707
    • /
    • 2001
  • A performance analysis of a SOFC/MGT hybrid system has been carried out for concept design. Thermo-dynamic models for each component being able to describe electrochemical characteristics and heat and mate-rial balance are proposed. Estimated is the power capacity of a SOFC suitable for the hybrid operation with a 5kW class MGT. Effects of current density and operating pressure are also investigated. Electric efficiency showed weak dependence on operating pressure and current density. It is desirable that the SOFC operates at high current density in manufacturing cost's point of view though operating with high current density slightly decreases the electric efficiency find specific power.

  • PDF

2축 병렬형 하이브리드 차량의 최저 연비 주행 알고리즘 (An Operation Algorithm for a 2 Shaft Parallel Type Hybrid Electric Vehicle for Optimal Fuel Economy)

  • 최득환;김현수
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.122-130
    • /
    • 2001
  • In this paper, an operational algorithm for a 2-shaft parallel hybrid electric vehicle is suggested for the minimization of operation cost. The operation cost is obtained as a summation of the engine fuel cost and the motor electricity cost. The electrical cost function is estimated in case of motoring, and generating when the recuperation is carried out during the braking. In addition, weight function is introduced in order to maintain the battery state of charge. Based on the operation algorithm, the optimal engine operation point that minimizes the operation cost is obtained with respect to the required vehicle power for every state of charge of battery. The optimal operation point provides the optimal power distribution of the engine and the motor for a required vehicle power Simulation was performed and the fuel economy of the hybrid vehicle was compared to that of the conventional vehicle. Simulation results showed that hybrid vehicle's fuel economy can be improved as much as 45∼48% compared to the conventional vehicle's.

  • PDF

OPTIMAL TORQUE MANAGEMENT STRATEGY FOR A PARALLEL HYDRAULIC HYBRID VEHICLE

  • Sun, H.;Jiang, J.H.;Wang, X.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.791-798
    • /
    • 2007
  • The hydraulic hybrid vehicle(HHV) is an application of hydrostatic transmission technology to improve vehicle fuel economy and emissions. A relatively lower energy density of hydraulic accumulator and complicated coordinating operations between two power sources require a special energy management strategy to maximize the fuel saving potential. This paper presents a new type of configuration for parallel HHV to minimize the disadvantages of the hydraulic accumulator, as well as a methodology for developing an energy management strategy tailored specially for PHHV. Based on an analysis of the optimal energy distribution between two power sources over a representative urban driving cycle with a Dynamic Programming(DP) algorithm, a fuzzy-based optimal torque management strategy is designed and developed to control the torque distribution. Simulation results demonstrates that the optimal torque management strategy maximizes the advantages of this hybrid type of configuration, and the high power density characteristics of hydraulic technology effectively improve the robustness of the energy management strategy and fuel economy of the PHHV.

연료전지 하이브리드 자동차의 에너지 운용전략에 관한 기술조사 (Survey on Energy Management Strategy for Fuel Cell Hybrid Electric Vehicles)

  • 이남수;정구민;안현식;김도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.511-513
    • /
    • 2005
  • The fuel cell system has inherent limitation such as slow response time and low fuel economy especially at the low power region, and thus, the battery system has come to be used to compensate for the fuel cell system. This type of hybrid configuration has many advantages, however, the energy management strategy is essentially required. The work in this paper presents survey on recent power management strategies for fuel cell hybrid electric vehicles. For three power management strategies: basic control method. object function-based control method, and fuzzy logic-based control method. each strategy is reviewed and discussed with other strategy.

  • PDF

Interfacially Controlled Hybrid Thin-film Solar Cells Using a Solution-processed Fullerene Derivative

  • 남상길;송명관;김동호;김창수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.190.2-190.2
    • /
    • 2014
  • We report the origin of the improvement of the power conversion efficiency (PCE) of hybrid thin-film solar cells when a soluble C60 derivative, [6,6]-phenyl-$C_{61}$-butyric acid methyl ester (PCBM), is introduced as a hole-blocking layer. The PCBM layer could establish better interfacial contact by decreasing the reverse ark-saturation current density, resulting in a decrease in the probability of carrier recombination. The power conversion efficiency of this optimized device reached a maximum value of 8.34% and is the highest yet reported for hybrid thin-film solar cells.

  • PDF

태양광 계통연계형 하이브리드 변압기의 해석 및 성능시험 (Analysis and Performance Test of Hybrid Transformer used in the Grid-Connected Photovoltaic Generation System)

  • 김지호;박훈양;손진근
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.333-338
    • /
    • 2014
  • This paper concerns the development of the transformer that can reduce harmonics supplied to the system if the output of photovoltaic inverter in the photovoltaic system is grid-connected, and suggests that problems of harmonics and power factor degradation in the grid-connected photovoltaic system can be improved. In this study, the burden of increasing the investment in new facilities and securing their installation space due to harmonics has been substantially eased through the development of a hybrid transformer possessing unbalanced function and harmonics reduction function using zig-zag coils, and most of all, it is expected that the development of such high efficiency hybrid transformer possessing functions of transformation and reducing harmonics can improve the power quality as well as prevent damages caused by harmonics, leading to suppress unnecessary loss of electric power and thereby contribute to energy savings.

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters)

  • 김윤호;김수홍;이강희
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

전기자동차용 온보드 충전기를 위한 새로운 하이브리드 컨버터 (Novel Hybrid Converter for the On-Board Charger of Electric Vehicle)

  • Vu, Hai-Nam;Tran, Dai-Duong;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.52-53
    • /
    • 2015
  • This paper introduces a novel hybrid converter combining a full-bridge soft switching converter and a full-bridge LLC converter. In this topology all the primary switches can achieve ZVS and ZCS all over the operation range. An additional switch and a diode are added in the secondary side of full-bridge converter to eliminate the circulating current and to provide a separate freewheeling path. The hybrid structure makes it possible to deliver the power to the secondary all the time of operation, thereby improving the efficiency. The proposed topology is suitable for the applications such as on-board chargers for electric vehicles and high power dc-dc converters. A 6.6-kW prototype converter was implemented and 97.5% efficiency was obtained through the experiments.

  • PDF