• 제목/요약/키워드: Hybrid imaging

검색결과 124건 처리시간 0.025초

활주로 FOD 탐지 효율화를 위한 기술적 고찰 (A Study for Efficient Foreign Object Debris Detection on Runways)

  • 이광병;이종길;김동훈
    • 한국항공운항학회지
    • /
    • 제22권1호
    • /
    • pp.130-135
    • /
    • 2014
  • FOD(Foreign Object Debris) has the potential threat to damage aircraft during critical phases of take-off and landing roll with some objects including metal on the runway. FOD can be found anywhere on an airport's air operation areas such as runway, taxiway and apron. It can lead to catastrophic loss of life and airframe, and increased maintenance and operating costs. In this paper, we defined FOD and surveyed its riskiness and necessity of automatic FOD detection system. We compared the requirements of the environment in Korea to the FAA advisory circular. Also we analyzed operation methods of FOD detection systems already installed at some airports. Based on the surveys mentioned above, we propose hybrid type of FOD detection system considering the environment in Korea which uses millimeter wave radar, optical camera and thermal imaging camera to detect FOD efficiently. In management approach, fixed type of the system should be installed for real-time monitoring, and mobile type of the system can be used additionally.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

몬테카를로 시뮬레이션을 통한 Csl-Se 검출기의 구조 설계 (Structure design of Csl-Se Detector using Monte Carlo Simulation)

  • 박지군;강상식;최장용;이형원;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.420-423
    • /
    • 2002
  • In recent years, there has been keen interest in developing f1at panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy(angiography and cardiology), electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of CsI(Tl) photoemission layer and a-Se photoconductor layer to resolve conventional x-ray detector such as the direct detector using a-Se and the indirect detector using CsI(Tl)/a-Si. To design the structure of CsI(Tl)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m-Se$ film and $150{\mu}m-CsI\left(Tl \right)/a-Se\left( 30{\mu}m \right)$ film is 70% at 70 kVp. The absorption energy is 90% at $350{\mu}m-CsI(Tl)$.

  • PDF

Photocatalytic Hydrogen Production in Water-Methanol Mixture over Iron-doped CaTiO3

  • Jang, J. S.;Borse, P. H.;Lee, J. S.;Lim, K. T.;Jung, O. S.;Jeong, E. D.;Bae, J. S.;Kim, H. G.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.95-99
    • /
    • 2011
  • $CaTi_{1-x}Fe_xO_3(0{\leq}x{\leq}0.4)$ solid solution photocatalysts were synthesized by iron doping during the conventional solid state reaction at $1100^{\circ}C$ for 5 h and characterized by ultraviolet-visible (UV-vis) absorption spectroscopy, X-ray diffraction, morphological analysis. We found that $CaTi_{1-x}Fe_xO_3$ samples not only absorb UV but also the visible light photons. This is because the Fe substitution at Ti-site in $CaTi_{1-x}Fe_xO_3$ lattice induces the band transition from Fe3d to the Fe3d + Ti3d hybrid orbital. The photocatalytic activity of Fe doped $CaTiO_3$ samples for hydrogen production under UV light irradiation decreased with the increase in the Fe concentration. There exists an optimized concentration of iron in $CaTiO_3$, which yields a maximum photocatalytic activity under visible light ($\lambda\geq420nm$) photons.

The Detection of Yellow Sand with Satellite Infrared bands

  • Ha, Jong-Sung;Kim, Jae-Hwan;Lee, Hyun-Jin
    • 대한원격탐사학회지
    • /
    • 제22권5호
    • /
    • pp.403-406
    • /
    • 2006
  • An algorithm for detection of yellow sand aerosols has been developed with infrared bands. This algorithm is a hybrid algorithm that has used two methods combined. The first method used the differential absorption in brightness temperature difference between $11{\mu}m\;and\;12{\mu}m\;(BTD1)$. The radiation at $11{\mu}m$ is absorbed more than at $12{\mu}m$ when yellow sand is loaded in the atmosphere, whereas it will be the other way around when cloud is present. The second method uses the brightness temperature difference between $3.7{\mu}m\;and\;11{\mu}m(BTD2)$. This technique is sensitive to dust loading, which the BTD2 is enhanced by reflection of $3.7{\mu}m$ solar radiation. First the Principle Component Analysis (PCA), a form of eigenvector statistical analysis from the two methods, is performed and the aerosol pixel with the lowest 10% of the eigenvalue is eliminated. Then the aerosol index (AI) from the combination of BTD 1 and 2 is derived. We applied this method to Multi-functional Transport Satellite-l Replacement (MTSAT-1R) data and obtained that the derived AI showed remarkably good agreements with Ozone Mapping Instrument (OMI) AI and Moderate Resolution Imaging Spectroradiometer (MODIS) aerosol optical depth.

Accelerating Magnetic Resonance Fingerprinting Using Hybrid Deep Learning and Iterative Reconstruction

  • Cao, Peng;Cui, Di;Ming, Yanzhen;Vardhanabhuti, Varut;Lee, Elaine;Hui, Edward
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.293-299
    • /
    • 2021
  • Purpose: To accelerate magnetic resonance fingerprinting (MRF) by developing a flexible deep learning reconstruction method. Materials and Methods: Synthetic data were used to train a deep learning model. The trained model was then applied to MRF for different organs and diseases. Iterative reconstruction was performed outside the deep learning model, allowing a changeable encoding matrix, i.e., with flexibility of choice for image resolution, radiofrequency coil, k-space trajectory, and undersampling mask. In vivo experiments were performed on normal brain and prostate cancer volunteers to demonstrate the model performance and generalizability. Results: In 400-dynamics brain MRF, direct nonuniform Fourier transform caused a slight increase of random fluctuations on the T2 map. These fluctuations were reduced with the proposed method. In prostate MRF, the proposed method suppressed fluctuations on both T1 and T2 maps. Conclusion: The deep learning and iterative MRF reconstruction method described in this study was flexible with different acquisition settings such as radiofrequency coils. It is generalizable for different in vivo applications.

A New Robust Blind Crypto-Watermarking Method for Medical Images Security

  • Mohamed Boussif;Oussema Boufares;Aloui Noureddine;Adnene Cherif
    • International Journal of Computer Science & Network Security
    • /
    • 제24권3호
    • /
    • pp.93-100
    • /
    • 2024
  • In this paper, we propose a novel robust blind crypto-watermarking method for medical images security based on hiding of DICOM patient information (patient name, age...) in the medical imaging. The DICOM patient information is encrypted using the AES standard algorithm before its insertion in the medical image. The cover image is divided in blocks of 8x8, in each we insert 1-bit of the encrypted watermark in the hybrid transform domain by applying respectively the 2D-LWT (Lifting wavelet transforms), the 2D-DCT (discrete cosine transforms), and the SVD (singular value decomposition). The scheme is tested by applying various attacks such as noise, filtering and compression. Experimental results show that no visible difference between the watermarked images and the original images and the test against attack shows the good robustness of the proposed algorithm.

<블랙 스완>(2013)의 몰핑 기술을 통해 본 포스트 시네마의 신경-이미지적 특징 (The Characteristics of Neuro-image in Post-cinema through Morphing Technique in (2013))

  • 장미화;문재철
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제15권5호
    • /
    • pp.45-53
    • /
    • 2021
  • 디지털 몰핑은 영화의 내러티브를 효과적으로 표현하면서 현실 넘어서는 상상을 사실로 구현한다. <블랙 스완>(2013)에서 디지털적으로 구현된 몰핑 이미지는 포스트 시네마로서 오늘날 영화의 특징을 잘 보여주고 있는데, 컴퓨터 기술을 적극적으로 활용해 마술 같은 환각적 이미지를 제공한다. 디지털 몰핑 기술은 주인공이 발레를 추는 동안 기괴하게 변형되어 가는 신체를 현실과 환영이 구분되지 않게 제시함으로써 충격을 준다. 이러한 이미지는 어트랙션 효과로 그치지 않고 신자유주의 시대의 강도를 정동의 흐름으로 가시화해 낸다. 신체 변형의 기이한 효과는 신자유주의 현실의 징후인 것이다. 또한 이러한 몰핑 이미지는 파트리샤 피스터스가 말한 신경-이미지 체제의 부상을 말해준다. 디지털 스크린에 나타난 신경 병리학적인 양상들은 신경-이미지에 해당되는 것으로, 들뢰즈의 시간-이미지 체제를 넘어서 미래의 시간성을 띤다. <블랙 스완>의 몰핑의 경우 니나의 신체가 흑조와 혼종화 되어서 계속적으로 변화하는 동안 신경-이미지적인 특성이 두드러지게 나타난다. 신경 이미지로서 이 영화의 디지털 몰핑은 주체가 겪는 현실의 충격을 조절하는 효과를 지닌다. 이 영화의 몰핑은 디지털 시대의 사회적 통제의 효과이자 그 통제를 조절하는 포스트 시네마의 역량을 보여주고 있다.

타액에 오염된 상아질에 대한 콤포머의 접합양상 (THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN)

  • 조영곤;김병태;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

The Detection of Yellow Sand Using MTSAT-1R Infrared bands

  • Ha, Jong-Sung;Kim, Jae-Hwan;Lee, Hyun-Jin
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.236-238
    • /
    • 2006
  • An algorithm for detection of yellow sand aerosols has been developed with infrared bands from Moderate Resolution Imaging Spectroradiometer (MODIS) and Multi-functional Transport Satellite-1 Replacement (MTSAT-1R) data. The algorithm is the hybrid algorithm that has used two methods combined together. The first method used the differential absorption in brightness temperature difference between $11{\mu}m$ and $12{\mu}m$ (BTD1). The radiation at 11 ${\mu}m$ is absorbed more than at 12 ${\mu}m$ when yellow sand is loaded in the atmosphere, whereas it will be the other way around when cloud is present. The second method uses the brightness temperature difference between $3.7{\mu}m$ and $11{\mu}m$ (BTD2). The technique would be most sensitive to dust loading during the day when the BTD2 is enhanced by reflection of $3.7{\mu}m$ solar radiation. We have applied the three methods to MTSAT-1R for derivation of the yellow sand dust and in conjunction with the Principle Component Analysis (PCA), a form of eigenvector statistical analysis. As produced Principle Component Image (PCI) through the PCA is the correlation between BTD1 and BTD2, errors of about 10% that have a low correlation are eliminated for aerosol detection. For the region of aerosol detection, aerosol index (AI) is produced to the scale of BTD1 and BTD2 values over land and ocean respectively. AI shows better results for yellow sand detection in comparison with the results from individual method. The comparison between AI and OMI aerosol index (AI) shows remarkable good correlations during daytime and relatively good correlations over the land.

  • PDF