• 제목/요약/키워드: Hybrid heating

검색결과 196건 처리시간 0.027초

Multifunctional Thin Film Resistors Prepared by ALD for High-Efficiency Inkjet Printheads

  • Kwack, Won-Sub;Kwon, Se-Hun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.126-126
    • /
    • 2012
  • In past decades, the themal inkjet (TIJ) printer has been widely used as one of the most well-known digital printing technology due to its low cost, and high printing quality. Since the printing speed of TIJ printers are much slower than that of laser printers, however, there has been intensive efforts to raise the printing speed of TIJ printers. One of the most plausible methods to raise the printing speed of TIJ printers is to adopt a page-wide array TIJ printhead. To accomplish this goal, the high efficiency inkjet heating resistor films should be developed to settle the high power consumption problem of a page-wide array TIJ printhead. In this study, we investigated noble metal based multicomponent thin film resistor films prepared by atomic layer deposition (ALD) for a high efficiency inkjet printhead. Design concept, preparation, material properties of noble metal based multicomponent thin films will be discussed in terms of mutlfunctionality.

  • PDF

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

겨울철 열펌프 작동온도에 따른 태양열 하이브리드 시스템의 성능특성에 관한 연구 (Study on the Performance Characteristics of the Solar Hybrid System with Heat Pump Operating Temperature during Winter Season)

  • 김원석;조홍현
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.821-827
    • /
    • 2010
  • Study on the performance characteristics of the solar hybrid system with heat pump operating temperature during winter season has performed by using an experimental test. The system performance and operating characteristics with the heat pump operating temperature, hour and load condition were investigated and analyzed. As a result, the hot water temperature was significantly affected by the heat pump operating temperature at the morning(time 1) and noon(time 2). However, hot water temperature was set by the radiation quality and collecting operation hour at the afternoon(time 3). In addition to the solar fraction was decreased for the high heat pump operating temperature because the heat pump operated with a long operating time and short operating period.

HDPE/Carbon Black/MWCNTs Hybrid 나노복합재료의 PTC 특성 (The PTC Characteristics of High Density Polyethylene/Carbon Black/MWCNTs Hybrid Nanocomposites)

  • 김성관;이중희
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.71-74
    • /
    • 2005
  • In this paper, the effects of the MWCNTs on the PTC characteristics of the conventional CB/polymer nanocomposites were investigated. For the uniform dispersion of the MWCNTs in the polymer matrix., nitricacid-treated MWCNTs were dispersed with the dissolved HOPE in the solvent. After evaporating solvent, the dried master batches in the oven were melt blended mixed with CB and HDPE to obtain the PTC materials. The initial resistivity of PTC materials decreased and the PTC intensity increased with the MWCNTs. During three repeated heating and cooling cycles, the PTC materials containing MWCNTs showed a great reproducibility due to the conductive network structures of CB particles and MWCNTs.

  • PDF

충돌분류시스템의 열전달 특성에 관한 수치적 연구 (Numerical Study on Heat Transfer Characteristics in Impinging Air Jet System)

  • 금성민;김동춘
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.55-61
    • /
    • 2003
  • Heat transfer characteristics for an air jet vertically impinging on a flat plate with a set of hybrid rods was investigated numerically using the RNG k-$\varepsilon$turbulent model. A commercial finite-volume code FLUENT is used. The rods had cross sections of half circular and rectangular shapes. The heating surface was heated with a constant heat flux value of $1020W/m^2$. Parameters investigated were the jet Reynolds number, nozzle -to-plate spacing, the rod pitch and rod-to-plate clearance. The local and average Nusselt number were found to be dependent on the rod pitch and the clearance because installing rods disturbed the flow. Higher convective heat transfer rate occurred in the whole plate as well as in the wall jet region.

지하도상가의 HVAC 구성방식에 따른 운전특성 연구 (An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage)

  • 이홍철;황인주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

반사판을 이용한 고정식 집광형 복합 Panel에 대한 연구 (A study on the fixed-concentrating hybrid panel using reflector)

  • 김완태;김규조;김승환;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.352-355
    • /
    • 2000
  • Although for its great amount and cleanness solar energy has been studied a lot as a substitute one, it is limitedly being utilized in heating water and partly in special usage for high cost of installing solar cell in Korea. Consider domestic shortage of natural energy resources and environmental issue by the Climate Agreement treated in 1994, it is urgently needed to study the practical application of solar energy as a substitute one. Therefore in order to increase the efficiency of solar cell and decrease its price, this study treats the course of designing and manufacturing the panel that connects sunlight by fixing reflector.

  • PDF

에너지절감을 도모하는 실내 온열환경 제어논리-Adaptive Model (New approaches of Indoor Environmental Control for Energy Saving-Adaptive Model)

  • 송두삼;가토 신스케
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.838-846
    • /
    • 2006
  • The purpose of this study to develop the air-conditioning system that adopts adaptive model as an indoor climate control logic for energy saving. The adaptive model using the ability of human thermal adaptation could be expected to alleviate the indoor set-point temperature compared with the past heat-balance model. Especially, in case of hybrid air-conditioning system coupled with natural ventilation and heating/cooling system, the adaptive model can be describe the thermal comfort of inhabitant who stay at hybrid system controlled buildings with accuracy. In this paper, the concept of adaptive model will be described and the results of a continuous measurement on the actual thermal experiences and behaviors of thermal adaptation for office worker will be reported.

  • PDF

해양 온도차발전 시스템의 열역학 사이클에 대한 연구 (A Study on the Thermodynamic Cycle of OTEC system)

  • 김남진;신상호;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.9-18
    • /
    • 2006
  • In this paper, the thermodynamic performance of OTEC cycle was examined. Computer simulation programs were developed for simple Rankine cycle, regenerative Rankine cycle, Kalina cycle, open cycle and hybrid cycle. For the simple Rankine cycle, the results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. Also, simple Rankine cycle OTEC power plant can practically generate electricity when the difference in warm and cold sea water inlet temperatures are greater than $14^{\circ}C$. The regenerative Rankine cycle showed a 1.5 to 2% increase in energy efficiency compared to the simple Rankine cycle while the Kalina cycle employing ammonia/water mixture showed a 2-to-3% increase in energy efficiency, and the overall cycle efficiencies of hybrid cycle and open cycle were 3.35% and 4.86%, respectively.

대형 Community 건물의 지열원 복합 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Analytical Study on the Performance of Ground Source Compound Hybrid Heat Pump System for Large Community Building)

  • 변재기;정동화;이종길;홍성호;최영돈;조성환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.634-637
    • /
    • 2008
  • Ground source heat pumps are clean, energy-efficient and environment-friendly systems cooling and heating. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a large community building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.

  • PDF