• 제목/요약/키워드: Hybrid desiccant cooling

검색결과 19건 처리시간 0.023초

열펌프, 데시칸트 및 증발식 냉각기를 조합한 하이브리드 냉방 시스템의 동특성 해석 연구 (Dynamic Simulation of a Hybrid Cooling System utilizing Heat Pump, Desiccant and Evaporative Cooler)

  • 서정남;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2011
  • Hybrid desiccant cooling system(HDCS) consists of desiccant rotor, regenerative evaporative cooler, heat pump and district heating hot water coil. In this study, TRNSYS and EES, dynamic and steady simulation programs were used for studying hybrid desiccant cooling system which is applied to an apartment house from June to August. The results show that power consumption of the hybrid desiccant cooling system is 70 kWh in June, 199 kWh in July and 241 kWh in August. Sensible and latent heats removed by the hybrid desiccant cooling system are 300 kWh, 301 kWh in June, 610 kWh, 858 kWh in July and 719 kWh, 1010 kWh in August. COP of the hybrid desiccant cooling system is 8.6 in June, 7.4 in July and 7.2 in August. COP of the hybrid desiccant cooling system decreases when latent heat load increases. Operation time of the system is 70 hours in June, 190 hours in July and 229 hours in August. Since the cooling load is largest in August, the operation time of August is longest for maintaining the indoor temperature at $26^{\circ}C$. Due to the characteristics of hybrid desiccant cooling system for efficiently handling both sensible and latent loads, this system can handle sensible and latent heat loads efficiently in summer.

기후 시나리오 SSP5와 SSP1에서의 2100년 서울 지역에서의 여름철 주택 냉방을 위한 하이브리드 제습 냉방 시스템 성능 분석 (Performance Analysis of a Hybrid Desiccant Cooling System for Residential Air Conditioning in the Seoul Region under the Climate Scenarios SSP5 and SSP1)

  • 이율호;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.773-784
    • /
    • 2023
  • In this study, a comparative analysis between an electric heat pump cooling system and a hybrid desiccant cooling system is conducted. Desiccant cooling is a thermal driven system with potentially lower electric power consumption than electric heat pump. Hybrid desiccant cooling system simulation includes components such as a desiccant rotor, direct and indirect evaporative coolers, heat exchangers, fans, and a heat pump system. Using dynamic simulations by climate conditions, house cooling temperatures and power consumption for both systems are analyzed for 16 days period in the summer season under climate scenarios for the year 2100 prediction. The results reveal that the hybrid desiccant cooling system exhibits a 5-18% reduction in electric consumption compared to the heat pump system.

하이브리드 냉풍건조기 개발 (Development of the hybrid desiccant cooling dryer)

  • 최현웅;정광섭;이태호;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.236-241
    • /
    • 2009
  • After analyzing the characteristics of the cooling dryer, the mixed cooling dryer was developed by adding the desiccant dryer which supplement the cooling dryer's demerits. Also, the hybrid desiccant cooling dryer was developed to use effectively the exhaust heat energy of the cooling dryer. It could make a more that 20 percent reduction in energy compared with the mixed desiccant cooling dryer. It has become essential to supply this equipment and search the suitable drying product.

  • PDF

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석 (Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System)

  • 인정현;이율호;강상규;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

하이브리드 데시칸트 선박도장용 제습기 (Hybrid Desiccant Dehumidifier for Shipbuilding Painting)

  • 박승태;금종수;김희재;김동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.248-253
    • /
    • 2009
  • For the energy's effective utilization, the mixed humidifier has been developed and popularized by combining the cooling dehumidifier with the desiccant humidifier properly. This has contributed in many ways to the industry. Hybrid Desiccant Dehumidifier that would be shown in this study could be indispensible in site due to the reduced equipment, with more than 50% reduction in energy.

  • PDF

지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석 (Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment)

  • 안준;김재율;강병하
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.571-579
    • /
    • 2014
  • 하절기 에너지 이용의 합리화를 위해서는 소형 열병합 발전의 설비이용률을 높일 수 있는 지역냉방의 보급이 확대되어야 한다. 지역냉방에는 흡수식 냉동기와 제습냉방기 있는데 상대적으로 낮은 열원을 사용할 수 있어 지역난방에 연계할 수 있는 제습냉방이 공동주택용으로 각광을 받고 있다. 본 논문에서는 고체제습제를 이용며 현열로터 대신에 히트펌프를 사용한 하이브리드 제습냉방 시스템의 주거환경에서의 성능 특성을 분석하였다. 실내공급공기, 실내리턴공기, 실외흡입공기, 재생열량, 소비전력을 측정하여 인터넷을 이용한 모니터링을 통하여 데이터를 분석하였다. 전체에너지는 외기온도가 증가할수록 감소하였고 냉방능력은 외기온도가 증가할수록 증가하고, 외기습도가 감소할수록 증가하는 경향을 보였다. 성능계수는 냉방능력과 유사한 경향을 보이는 것으로 분석되었다.

실증 실험을 통한 하이브리드 제습냉방 시스템의 성능 분석 (Performance Analysis of Hybrid Desiccant Chiller Based on Field Test)

  • 안준;윤창호;강병하
    • 대한기계학회논문집B
    • /
    • 제37권7호
    • /
    • pp.621-627
    • /
    • 2013
  • 2011년 7월과 8월에 걸쳐 하이브리드 제습냉방기의 실증 실험를 진행하였다. 계측 자료들은 인터넷 회선을 통해 원격 모니터링을 하며 및 취득하였다. 취득한 자료를 바탕으로 하여 하이브리드 제습냉방시스템의 실거주 환경에서 외기조건에 따른 성능을 분석하였다. 또한 실증실험에서 나타난 외기 조건에 대해 성능 시뮬레이션을 수행하여 실험값과 비교하였다. 실험과 시뮬레이션 결과는 대체로 일치하였다. 외기습도가 높은 경우 예측결과와 같이 실증 실험에서도 시스템 성능이 감소하는 것이 확인되었다.

자동차 냉방시스템에서 건조기 일체형 응축기 개발 (Development on the Sub-Cooled Hybrid Condenser in Automotive Air-Conditioning System)

  • 김경훈;장주섭;박종일
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.70-76
    • /
    • 2003
  • An experimental study was performed to understand the heat transfer and fluid dynamic characteristics of Sub-Cooled Hybrid Condenser (SCHC), which conventional condenser and receiver dryer are integrated into. SCHC also employs a sub-cooled refrigerant passages at the end of the condenser in order to supply perfect liquid refrigerant to the expansion unit. Throughout the present study, it was found that the developed SCHC increases in the degree of sub-cooling by 10~100% compared to conventional condenser. The excessive sub-cooling has improved the cooling performance by 10%, and that leads reduction in evaporator outlet air temperature by $1.5^{\circ}C$. Also found through the study is that the refrigerant pressure drop across SCHC is fairly increased due to insertion of the desiccant cartridge in the receiver tank which is composed of zeolite, filter and supporter plate.

휜-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics with Height of a Fin-Tube Liquid Desiccant Dehumidifier)

  • 이수동;박문수;정진은;최영석
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.594-603
    • /
    • 2004
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristics of working factor variables such as inlet solution flow rate, air flow rate, solution concentration and brine temperature have been analyzed. This dehumidifier has the ability to provide running while saving the latent heat load of total energy. The result of this experiment can provide useful data for hybrid air conditioning system.